Miroslav Kuzmanović

Miroslav Kuzmanović

Auto-generated profile, based on publicly available information

Miroslav Kuzmanović

Univ Belgrade, Fac Phys Chem, Studentski Trg 12-16, Belgrade 11000, Serbia

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Microchemical Journal
Verified
Journal Article
Closed access
Sanja ZivkovicSanja Zivkovic
Sanja Zivkovic
JSJelena J Savovic
Jelena J Savovic
MKMiroslav Kuzmanovic
Miroslav Kuzmanovic
Jelena D. PetrovićJelena D. Petrović
Jelena D. Petrović
MMMilos Momcilovic
Milos Momcilovic

1 April 2015 in Applied Spectroscopy
Verified
Journal Article
Closed access
MMMiloš D. Momčilović
Miloš D. Momčilović
MKMiroslav Kuzmanovic
Miroslav Kuzmanovic
Dragan RankovićDragan Ranković
Dragan Ranković
JCJovan Ciganovic
Jovan Ciganovic
Milovan M. M. StoiljkovićMilovan M. M. Stoiljković
Milovan M. M. Stoiljković
MTMilan S. Trtica
Milan S. Trtica
Spatially resolved, time-integrated optical emission spectroscopy was applied for investigation of copper plasma produced by a nanosecond infrared (IR) transversely excited atmospheric (TEA) CO2 laser, operating at 10.6 μm. The effect of surrounding air pressure, in the pressure range 0.1 to 1013 mbar, on plasma formation and its characteristics was investigated. A linear dependence of intensity threshold for plasma formation on logarithm of air pressure was found. Lowering of the air pressure reduces the extent of gas breakdown, enabling better laser-target coupling and thus increases ablation. Optimum air pressure for target plasma formation was 0.1 mbar. Under that pressure, the induced plasma consisted of two clearly distinguished and spatially separated regions. The maximum intensity of emission, with sharp and well-resolved spectral lines and negligibly low background emission, was obtained from a plasma zone 8 mm from the target surface. The estimated excitation temperature in this zone was around 7000 K. The favorable signal to background ratio obtained in this plasma region indicates possible analytical application of TEA CO2 laser produced copper plasma. Detection limits of trace elements present in the Cu sample were on the order of 10 ppm (parts per million). Time-resolved measurements of spatially selected plasma zones were used to find a correlation between the observed spatial position and time delay. Index Headings: Laser induced Cu-plasma emission; Shock wave plasma; Copper target; Transversely excited atmospheric CO2 laser; TEA CO2 laser.

1 March 1996 in Spectroscopy Letters
Verified
Journal Article
Closed access
MKMiroslav M. Kuzmanović
Miroslav M. Kuzmanović
MPMirjana S. Pavlović
Mirjana S. Pavlović
MMMomir Marinković
Momir Marinković
The application of a U-shaped d.c. arc with aerosol supply for analysis of fresh waters has been described. Limits of detection obtained with d.c. plasma compare well with those reported for ICP. A number of spectral lines and molecular bands were examined and the most suitable are selected to ensure the best limits of detection or wide dynamic ranges. Limits of detection in ng ml−1, given in the parenthesis, following the element symbol, are: Al(0.9), B(0.6), Ba(0.2), Be(0.15), Ca(0.05), Cd(3.5), Co(1.1), Cr(0.2), Fe(2.4), Ga(0.5), Hg(9.0), K(0.3), Li(0.008), Mg(0.4), Mn(0.3), Mo(0.7), Na(0.04), Ni(2.0), P(45), Pb(12), Si(9.0), Sr(0.04), Zn(1.3).

10 February 2022 in Plasma Chemistry and Plasma Processing
Verified
Journal Article
Closed access
PDF file
Jelena D. PetrovićJelena D. Petrović
Jelena D. Petrović
JSJelena J Savovic
Jelena J Savovic
DRDragan Rankovic
Dragan Rankovic
MKMiroslav Kuzmanovic
Miroslav Kuzmanovic

1 April 2016 in Spectrochimica Acta Part B: Atomic Spectroscopy
Verified
Journal Article
Closed access
JSJelena J Savovic
Jelena J Savovic
Milovan M. M. StoiljkovićMilovan M. M. Stoiljković
Milovan M. M. Stoiljković
MKMiroslav Kuzmanovic
Miroslav Kuzmanovic
MMMiloš D. Momčilović
Miloš D. Momčilović
JCJovan Ciganovic
Jovan Ciganovic
MTMilan S. Trtica
Milan S. Trtica

1 April 2013 in Applied Surface Science
Verified
Journal Article
Closed access
MMMiloš D. Momčilović
Miloš D. Momčilović
MTMilan S. Trtica
Milan S. Trtica
JCJovan Ciganovic
Jovan Ciganovic
JSJelena J Savovic
Jelena J Savovic
JSJ. Stasic
J. Stasic
MKM. Kuzmanovic
M. Kuzmanovic