Florian Kernen

Florian Kernen

Auto-generated profile, based on publicly available information

Florian Kernen

Department of Oral and Maxillofacial Surgery, Translational Implantology, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2020 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
FKFlorian Kernen
Florian Kernen
JKJaap Kramer
Jaap Kramer
LWLaura Wanner
Laura Wanner
DWDaniel Wismeijer
Daniel Wismeijer
KNKatja Nelson
Katja Nelson
TFTabea Flügge
Tabea Flügge
Background: Virtual implant planning systems integrate (cone beam-) computed tomography data to assess bone quantity and virtual models for the design of the implant-retained prosthesis and drill guides. Five commercially available systems for virtual implant planning were examined regarding the modalities of integration of radiographic data, virtual dental models and the design of drill guides for guided implant surgery. The purpose of this review was to describe the limitations of these available systems regarding the import of imaging data and the design and fabrication of a drill guide.Methods: The following software systems were examined regarding the import of imaging data and the export of the virtual implant planning for the design and fabrication of a drill guide with the help of two clinical situations requiring dental implant therapy: coDiagnostiX™, DentalWings, Canada (CDX); Simplant Pro™, Dentsply, Sweden (SIM); Smop™, Swissmeda, Switzerland (SMP); NobelClinician™, Nobel Biocare, Switzerland (NC); Implant Studio, 3Shape, Denmark (IST). Assessment criteria included data formats and management as well as the workflow for the design and production of drill guides.Results: All systems have a DICOM-interface (“Digital Imaging and Communication in Medicine”) for the import of radiographic data. Imaging artefacts could be reduced but not eliminated by manual data processing. The import of virtual dental models in a universal format (STL: Standard Tesselation Language) was possible with three systems; one system could only be used with a proprietary data format.All systems display three-dimensional surface models or two-dimensional cross-sections with varying orientation for virtual implant planning. Computer aided design and manufacturing (CAD/CAM) of drill guides may be performed by the user with the help of default parameters or solely by the provider of the software and thus without the influence of the clinician.Conclusion: Data bases of commonly used implant systems are available in all tested software, however not all systems allow to plan and execute fully guided implant placement. An individual design and in-house manufacturing of the drill guide is only available in some software systems. However, at the time of publication most recent software versions showed flexibility in individual design and in-house manufacturing of drill guides.

1 December 2022 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Open access
FKFlorian Kernen
Florian Kernen
SSStefan Schlager
Stefan Schlager
VAVeronica Seidel Alvarez
Veronica Seidel Alvarez
JMJürgen Mehrhof
Jürgen Mehrhof
KVKirstin Vach
Kirstin Vach
TFTabea Flügge
Tabea Flügge
The accuracy of intraoral scanners is a prerequisite for the fabrication of dental restorations in computer-aided design and computer-aided manufacturing (CAD-CAM) dentistry. While the precision of intraoral scanners has been investigated in vitro, clinical data on the accuracy of intraoral scanning (IOS) are limited. The purpose of this clinical study was to determine the accuracy of intraoral scanning with different devices compared with extraoral scanning. An experimental appliance was fabricated for 11 participants and then scanned intraorally and extraorally with 3 different intraoral scanners and a reference scanner. Intraoral and extraoral scans were subdivided into complete-arch and short-span scans and compared with the reference scan to assess trueness. Repeated scans in each group were assessed for precision. Precision and trueness were higher for extraoral scans compared with intraoral scans, except for complete-arch scans with 1 intraoral scanner. The median precision of short-span scans was higher (extraoral: 22 to 29 μm, intraoral: 23 to 43 μm) compared with complete-arch scans (extraoral: 81 to 165 μm, intraoral: 80 to 198 μm). The median trueness of short-span scans (extraoral: 28 to 40 μm, intraoral: 38 to 47 μm) was higher than that of complete-arch scans (extraoral: 118 to 581 μm, intraoral: 147 to 433 μm) for intraoral and extraoral scanning. Intraoral conditions negatively influenced the accuracy of the scanning devices, which was also reduced for the complete-arch scans.

30 January 2022 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
TFTabea Flügge
Tabea Flügge
JKJaap Kramer
Jaap Kramer
KNKatja Nelson
Katja Nelson
SNSusanne Nahles
Susanne Nahles
FKFlorian Kernen
Florian Kernen
Background: Patient- and technology-related parameters influence the successful implementation of virtual implant planning and guided implant surgery. Besides data processing and computer aided design of drill guides as described in Part I, the possibilities and limitations for prosthetic set-up and virtual implant planning are essential (Part II). Methods: The following software systems were examined using two different clinical situations for implant therapy: coDiagnostiX™, DentalWings, Canada (CDX); Simplant Pro™, Dentsply, Sweden (SIM); Smop™, Swissmeda, Switzerland (SMP); NobelClinician™, Nobel Biocare, Switzerland (NC); Implant Studio, 3Shape, Denmark (IST). Assessment criteria geared towards interfaces and integrated tools for prosthetic set-up and virtual implant planning. Results: A software interface for an individual virtual prosthetic set-up was provided by two systems (CDX, IST), whereas the set-up of standardized teeth was provided by four systems (CDX, SIM, SMP, IST). Alternatively, a conventional set-up could be scanned and imported. One system could solely work with the digitization of a conventional set-up for virtual implant planning (NC). Stock abutments could be displayed for implant planning, but none of the tested software systems provided tools for the design of an individual abutment. All systems displayed three-dimensional reconstructions or two-dimensional cross-sections with varying orientation for virtual implant placement. The inferior alveolar nerve could be marked to respect a minimum distance between the nerve and the planned implant. Three implant planning systems provided a library to display more than 50 implant systems (CDX, SIM, IST), one system provided 33 implant systems (SMP) and one implant system provided 4 implant systems (NC). Conclusion: Depending on the used software system, there are limited options for a virtual set-up, virtual articulators and the display of a virtual prosthetic set-up. The implant systems used by the clinician is important for the decision which software system to choose, as there is a discrepancy between available implant systems and the number of supported systems in each software.

28 July 2022 in Clinical Oral Implants Research
Verified
Journal Article
Open access
FKFlorian R. Kernen
Florian R. Kernen
MRMario Recca
Mario Recca
Kirstin VachKirstin Vach
Kirstin Vach
SNSusanne Nahles
Susanne Nahles
KNKatja Nelson
Katja Nelson
TFTabea V. Flügge
Tabea V. Flügge
Objectives: Optical impressions of implants in the edentulous arch are challenged by the absence of distinct surface morphology between multiple implant scan bodies. The purpose of this in vitro study was to evaluate a newly developed scan aid in various designs and colors to improve the accuracy of multi‐implant scans.Materials and Methods: A universal scan aid in three different designs (circular, square, irregular) and three different materials (colors: beige, gray, white) was applied to the implant scan bodies of a master model of six implants in an edentulous maxilla. Ten scans using an intra‐oral scanner of each scan aid were acquired. Reference scanning was performed using a desktop optical scanner. Alignment of scans was performed at the first scan body in a three‐dimensional modeling and inspection software and deviations for trueness and precision were calculated using the signed nearest‐neighbor method and then statistically analyzed (α = .05).Results: Overall, the beige irregular scan aid had the highest trueness and showed significant differences compared to unsplinted scans. The precision showed more heterogenous results and decreased when using the scan aid. Ease of use was observed with the irregular gray scan aid due to its increased elongation at break.Conclusions: The evaluated scan aid led to improved trueness when compared to unsplinted scans. Even though the irregular design in beige color showed highest trueness, the poor fracture strength of the tested material requires further improvement.

14 June 2023 in Clinical Oral Implants Research
Verified
Journal Article
Open access
FKFlorian Kernen
Florian Kernen
DBDominik Brändle
Dominik Brändle
OWOliver Wagendorf
Oliver Wagendorf
MRMario Recca
Mario Recca
JMJürgen Mehrhof
Jürgen Mehrhof
TFTabea Flügge
Tabea Flügge
Objectives: Intraoral scans of multiple implants in the edentulous arch are challenged by the absence of a distinct surface morphology between scan bodies. A scan aid was applied in such situation and evaluated for intraoral scanning accuracy in vivo.Materials and Methods: 87 implants in 22 patients were scanned with scan aid (SA) and without scan aid (NO) using two different intraoral scanners (CS3600 [CS] and TRIOS3 [TR]). Master casts were digitized by a laboratory scanner. Virtual models were superimposed using an inspection software and Linear deviation and precision were measured. Statistical analysis was performed using linear mixed models (α = .05).Results: Total mean linear deviation within the CS group was 189 μm without scan aid and 135 μm when using the scan aid. The TR group's total mean deviation was 165 μm with and without a scan aid. Significant improvement with scan aid was observed for the CS group (p = .001), and no difference was found in the TR group. 96% of scan bodies were successfully scanned in the TR‐SA group compared to 86% for the TR‐NO group, 83% for the CS‐SA, and 70% for the CS‐NO group, respectively.Conclusions: The evaluated scan aid improved linear deviation compared to unsplinted scans for the CS group but not for the TR group. These differences could originate from different scanning technologies used, active triangulation (CS) and confocal microscopy (TR). The scan aid improved the ability to recognize scan bodies successfully with both systems, which could have a favorable clinical impact overall.

4 January 2025 in Journal of Dentistry
Verified
Journal Article
Open access
AKA. Kernen-Gintaute
A. Kernen-Gintaute
MAM. Akulauskas
M. Akulauskas
FKF. Kernen
F. Kernen
NZNicola Ursula Zitzmann
Nicola Ursula Zitzmann
Benedikt SpiesBenedikt Spies
Benedikt Spies
FBFelix Burkhardt
Felix Burkhardt
This clinical study aimed to evaluate the accuracy of digital and conventional implant impressions in a fully edentulous maxilla and mandible. A 53-year-old edentulous patient with four maxillary and two mandibular implants was selected. Ten intraoral scans (IOS) and a conventional impression per jaw were taken. Clinically verified upper and lower plaster models were digitized using both optical (reference data, n = 10 per model) and tactile laboratory scanner (n = 10 per model). Accuracy was evaluated by comparing the precision and linear/angular deviations of the implants with the reference data. Statistical analyses were conducted using Student's t-test and Kruskal-Wallis test (α = 0.05). In the maxilla, the most significant linear deviations exceeding the 100 µm threshold were found with IOS between implants 1-4. In the mandible, all linear deviations remained below 55 µm. Angular deviations between implants after IOS ranged from 0.01° to 0.40° in the mandible and <0.01° to 1.86° in the maxilla. After tactile scanning, linear deviations did not exceed 100 µm threshold (except in one distance) and angular deviations ranged from 0.04° to 0.54° (mandible) and <0.01° to 2.50° (maxilla). The optical scanner demonstrated significantly higher precision (p < 0.001) compared to the IOS and tactile scanner. Given the significant deviations observed, especially in the maxilla, the optical scanner following conventional impressions remained the preferred method for fully edentulous cases due to its superior accuracy. IOS could be a viable alternative particularly for shorter distances in the edentulous jaw, although the clinical implications of these deviations need to be investigated in future studies.