Mykolas Akulauskas

Mykolas Akulauskas

Auto-generated profile, based on publicly available information

Mykolas Akulauskas

Biomedical Engineering Institute, Kaunas University of Technology, Kaunas, Lithuania

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2025 in Journal of Dentistry
Verified
Journal Article
Open access
AKA. Kernen-Gintaute
A. Kernen-Gintaute
MAM. Akulauskas
M. Akulauskas
FKF. Kernen
F. Kernen
NZNicola Ursula Zitzmann
Nicola Ursula Zitzmann
Benedikt SpiesBenedikt Spies
Benedikt Spies
FBFelix Burkhardt
Felix Burkhardt
This clinical study aimed to evaluate the accuracy of digital and conventional implant impressions in a fully edentulous maxilla and mandible. A 53-year-old edentulous patient with four maxillary and two mandibular implants was selected. Ten intraoral scans (IOS) and a conventional impression per jaw were taken. Clinically verified upper and lower plaster models were digitized using both optical (reference data, n = 10 per model) and tactile laboratory scanner (n = 10 per model). Accuracy was evaluated by comparing the precision and linear/angular deviations of the implants with the reference data. Statistical analyses were conducted using Student's t-test and Kruskal-Wallis test (α = 0.05). In the maxilla, the most significant linear deviations exceeding the 100 µm threshold were found with IOS between implants 1-4. In the mandible, all linear deviations remained below 55 µm. Angular deviations between implants after IOS ranged from 0.01° to 0.40° in the mandible and <0.01° to 1.86° in the maxilla. After tactile scanning, linear deviations did not exceed 100 µm threshold (except in one distance) and angular deviations ranged from 0.04° to 0.54° (mandible) and <0.01° to 2.50° (maxilla). The optical scanner demonstrated significantly higher precision (p < 0.001) compared to the IOS and tactile scanner. Given the significant deviations observed, especially in the maxilla, the optical scanner following conventional impressions remained the preferred method for fully edentulous cases due to its superior accuracy. IOS could be a viable alternative particularly for shorter distances in the edentulous jaw, although the clinical implications of these deviations need to be investigated in future studies.

24 August 2022 in Journal of Dentistry
Verified
Journal Article
Closed access
VRVygandas Rutkunas
Vygandas Rutkunas
VBV. Bilius
V. Bilius
TST. Simonaitis
T. Simonaitis
LAL. Auskalnis
L. Auskalnis
JJJ. Jurgilevicius
J. Jurgilevicius
MAM. Akulauskas
M. Akulauskas

1 January 2024 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
VRVygandas Rutkunas
Vygandas Rutkunas
DJDarius Jegelevičius
Darius Jegelevičius
JPJustinas Pletkus
Justinas Pletkus
LALiudas Auškalnis
Liudas Auškalnis
MAMykolas Akulauskas
Mykolas Akulauskas
AGAgnė Gedrimienė
Agnė Gedrimienė
Rutkūnas V, et al. J Adv Prosthodont. 2024 Oct;16(5):302-310. https://doi.org/10.4047/jap.2024.16.5.302

12 June 2026 in Journal of Dentistry
Verified
Journal Article
Closed access
VRVygandas Rutkunas
Vygandas Rutkunas
AKAndrius Kubilius
Andrius Kubilius
MAMykolas Akulauskas
Mykolas Akulauskas
JBJudit Borbély
Judit Borbély
BKBarbara Kispelyi
Barbara Kispelyi
DSDominykas Stasiūnas
Dominykas Stasiūnas

19 June 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MAMykolas Akulauskas
Mykolas Akulauskas
DJDarius Jegelevičius
Darius Jegelevičius
VRVygandas Rutkūnas
Vygandas Rutkūnas
The incorporation of intraoral scanners (IOS) into dental implantology has notably increased the efficiency of clinical workflows. One of the key features of any IOS system is their accuracy, which defines how well scanner digitizes the scanned surfaces. In this study, CARES RC Mono intraoral scan bodies (ISB) extracted from digitized dental arches were used to evaluate the digitization accuracy of one laboratory scanner (E4) and four intraoral scanners (Trios 3, Trios 4, Carestream 3600 and Primescan). The proposed accuracy evaluation method reverse-engineers the surface of the extracted intraoral scan body. It starts by identifying well-defined intraoral scan body surfaces, then creates their respective geometric primitives, and uses them to generate a CAD (computer-aided design) model on top of the scanned surface. Two measurement types were used: the accuracy of the created CAD model and the 3D surface deviation between each defined ISB part and the CAD model. This approach bypasses the conventional fine alignment method in favor of a more elaborate and versatile evaluation algorithm, which can be used to evaluate any cylindrical-shaped ISB. Nine parameters were evaluated for each extracted scan body. Based on these evaluations, E4 demonstrated the best results, followed by Primescan scanner. The remaining scanners showed only minor differences in accuracy between them.