25 July 2022 in Magnetic Resonance in Medicine
Purpose: Quantitative multi‐parameter mapping (MPM) has been shown to provide good longitudinal and cross‐sectional reproducibility for clinical research. Unfortunately, acquisition times (TAs) are typically infeasible for routine scanning at high resolutions.Methods: A fast whole‐brain MPM protocol based on interleaved multi‐shot 3D‐EPI with controlled aliasing (SC‐EPI) at 3T and 7T is proposed and compared with MPM using a standard spoiled gradient echo (FLASH) sequence. Four parameters (R1, PD, , and MTsat) were measured in less than 3 min at 1 mm isotropic resolution. Five subjects went through the same scanning sessions twice at each scanner. The intra‐subject coefficient of variation (scan–rescan) (CoV) was estimated for each protocol and scanner to assess the longitudinal reproducibility.Results: At 3T, the CoV of SC‐EPI ranged between 1.2%–4.8% for PD and R1, 2.8%–10.6% for and MTsat, which was comparable with FLASH (0.6%–4.9% for PD and R1, 2.6%–11.3% for and MTsat). At 7T, where the SC‐EPI TA was reduced to ∼2 min, the CoV of SC‐EPI (1.4%–10.6% for PD, R1, and ) was 1.2–2.4 times larger than the CoV of FLASH (1.0%–15%) and MTsat showed much higher variability across subjects. The SC‐EPI‐MPM protocol at 3T showed high reproducibility and yielded stable quantitative maps at a clinically feasible resolution and scan time, whereas at 7T, MT saturation homogeneity needs to be improved.Conclusion: SC‐EPI‐based MPM is feasible as an additional MRI modality in clinical or population studies where the parameters offer great potential as biomarkers.
10 July 2024 in Magnetic Resonance in Medicine
Purpose: The transverse relaxation time T holds significant relevance in clinical applications and research studies. Conventional T mapping approaches rely on spin‐echo sequences, which require lengthy acquisition times and involve high radiofrequency (RF) power deposition. An alternative gradient echo (GRE) phase‐based T mapping method, utilizing steady‐state acquisitions at one small RF spoil phase increment, was recently demonstrated. Here, a modified magnitude‐ and phase‐based T mapping approach is proposed, which improves estimations by simultaneous fitting of and signal amplitude () at three or more RF spoiling phase increments, instead of assuming a fixed value.Methods: The feasibility of the magnitude‐phase‐based method was assessed by simulations, in phantom and in vivo experiments using skipped‐CAIPI three‐dimensional‐echo‐planar imaging (3D‐EPI) for rapid GRE imaging. , and PD estimations obtained by our method were compared to of the phase‐based method and and PD of spoiled GRE‐based multi‐parameter mapping using a multi‐echo version of the same sequence.Results: The agreement of the proposed with ground truth and reference values was higher than that of phase‐based in simulations and in phantom data. While phase‐based overestimation increases with actual and , the proposed method is accurate over a large range of physiologically meaningful and values. At the same time, precision is improved. In vivo results were in line with these observations.Conclusion: Accurate magnitude‐phase‐based T mapping is feasible in less than 5 min scan time for 1 mm nominal isotropic whole‐head coverage at 3T and 7T.