Philipp Ehses

Philipp Ehses

Auto-generated profile, based on publicly available information

Philipp Ehses

German Center for Neurodegenerative Diseases (DZNE) Bonn Germany

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
PEPhilipp Ehses
Philipp Ehses
DBDaniel Brenner
Daniel Brenner
RSRüdiger Stirnberg
Rüdiger Stirnberg
EPEberhard D. Pracht
Eberhard D. Pracht
TSTony Stöcker
Tony Stöcker

15 August 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
MVMarten Veldmann
Marten Veldmann
PEPhilipp Ehses
Philipp Ehses
KCKelvin Chow
Kelvin Chow
JNJon‐Fredrik Nielsen
Jon‐Fredrik Nielsen
MZMaxim Zaitsev
Maxim Zaitsev
TSTony Stöcker
Tony Stöcker
Purpose: This work presents an end‐to‐end open‐source MR imaging workflow. It is highly flexible in rapid prototyping across the whole imaging process and integrates vendor‐independent openly available tools. The whole workflow can be shared and executed on different MR platforms. It is also integrated in the JEMRIS simulation framework, which makes it possible to generate simulated data from the same sequence that runs on the MRI scanner using the same pipeline for image reconstruction.Methods: MRI sequences can be designed in Python or JEMRIS using the Pulseq framework, allowing simplified integration of new sequence design tools. During the sequence design process, acquisition metadata required for reconstruction is stored in the MR raw data format. Data acquisition is possible on MRI scanners supported by Pulseq and in simulations through JEMRIS. An image reconstruction and postprocessing pipeline was implemented into a Python server that allows real‐time processing of data as it is being acquired. The Berkeley Advanced Reconstruction Toolbox is integrated into this framework for image reconstruction. The reconstruction pipeline supports online integration through a vendor‐dependent interface.Results: The flexibility of the workflow is demonstrated with different examples, containing 3D parallel imaging with controlled aliasing in volumetric parallel imaging (CAIPIRINHA) acceleration, spiral imaging, and B0 mapping. All sequences, data, and the corresponding processing pipelines are publicly available.Conclusion: The proposed workflow is highly flexible and allows integration of advanced tools at all stages of the imaging process. All parts of this workflow are open‐source, simplifying collaboration across different MR platforms or sites and improving reproducibility of results.

11 April 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
LVLenka Vaculčiaková
Lenka Vaculčiaková
KPKornelius Podranski
Kornelius Podranski
LELuke J. Edwards
Luke J. Edwards
DODilek Ocal
Dilek Ocal
TVThomas Veale
Thomas Veale
NWNikolaus Weiskopf
Nikolaus Weiskopf
Purpose: High‐resolution quantitative multi‐parameter mapping shows promise for non‐invasively characterizing human brain microstructure but is limited by physiological artifacts. We implemented corrections for rigid head movement and respiration‐related B0‐fluctuations and evaluated them in healthy volunteers and dementia patients.Methods: Camera‐based optical prospective motion correction (PMC) and FID navigator correction were implemented in a gradient and RF‐spoiled multi‐echo 3D gradient echo sequence for mapping proton density (PD), longitudinal relaxation rate (R1) and effective transverse relaxation rate (R2*). We studied their effectiveness separately and in concert in young volunteers and then evaluated the navigator correction (NAVcor) with PMC in a group of elderly volunteers and dementia patients. We used spatial homogeneity within white matter (WM) and gray matter (GM) and scan‐rescan measures as quality metrics.Results: NAVcor and PMC reduced artifacts and improved the homogeneity and reproducibility of parameter maps. In elderly participants, NAVcor improved scan‐rescan reproducibility of parameter maps (coefficient of variation decreased by 14.7% and 11.9% within WM and GM respectively). Spurious inhomogeneities within WM were reduced more in the elderly than in the young cohort (by 9% vs. 2%). PMC increased regional GM/WM contrast and was especially important in the elderly cohort, which moved twice as much as the young cohort. We did not find a significant interaction between the two corrections.Conclusion: Navigator correction and PMC significantly improved the quality of PD, R1, and R2* maps, particularly in less compliant elderly volunteers and dementia patients.

13 December 2024 in Nature Protocols
Verified
Journal Article
Closed access
PDF file
AKAlexandra Koch
Alexandra Koch
RSRüdiger Stirnberg
Rüdiger Stirnberg
SESantiago Estrada
Santiago Estrada
WZWeiyi Zeng
Weiyi Zeng
VLValerie Lohner
Valerie Lohner
MBMonique M. B. Breteler
Monique M. B. Breteler

25 July 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
DWDifei Wang
Difei Wang
PEPhilipp Ehses
Philipp Ehses
TSTony Stöcker
Tony Stöcker
RSRüdiger Stirnberg
Rüdiger Stirnberg
Purpose: Quantitative multi‐parameter mapping (MPM) has been shown to provide good longitudinal and cross‐sectional reproducibility for clinical research. Unfortunately, acquisition times (TAs) are typically infeasible for routine scanning at high resolutions.Methods: A fast whole‐brain MPM protocol based on interleaved multi‐shot 3D‐EPI with controlled aliasing (SC‐EPI) at 3T and 7T is proposed and compared with MPM using a standard spoiled gradient echo (FLASH) sequence. Four parameters (R1, PD, , and MTsat) were measured in less than 3 min at 1 mm isotropic resolution. Five subjects went through the same scanning sessions twice at each scanner. The intra‐subject coefficient of variation (scan–rescan) (CoV) was estimated for each protocol and scanner to assess the longitudinal reproducibility.Results: At 3T, the CoV of SC‐EPI ranged between 1.2%–4.8% for PD and R1, 2.8%–10.6% for and MTsat, which was comparable with FLASH (0.6%–4.9% for PD and R1, 2.6%–11.3% for and MTsat). At 7T, where the SC‐EPI TA was reduced to ∼2 min, the CoV of SC‐EPI (1.4%–10.6% for PD, R1, and ) was 1.2–2.4 times larger than the CoV of FLASH (1.0%–15%) and MTsat showed much higher variability across subjects. The SC‐EPI‐MPM protocol at 3T showed high reproducibility and yielded stable quantitative maps at a clinically feasible resolution and scan time, whereas at 7T, MT saturation homogeneity needs to be improved.Conclusion: SC‐EPI‐based MPM is feasible as an additional MRI modality in clinical or population studies where the parameters offer great potential as biomarkers.

25 May 2017 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
PEPhilipp Ehses
Philipp Ehses
KSKlaus Scheffler
Klaus Scheffler