Risha Bhatia

Risha Bhatia

Auto-generated profile, based on publicly available information

Risha Bhatia

Monash University, Melbourne, Australia

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2017 in The Journal of Pediatrics
Verified
Journal Article
Closed access
RBRisha Bhatia
Risha Bhatia
PDPeter G. Davis
Peter G. Davis
DTDavid G. Tingay
David G. Tingay

27 October 2023 in The Lancet Child & Adolescent Health
Verified
Journal Article
Closed access
AKAnna M Kidman
Anna M Kidman
BMBrett J Manley
Brett J Manley
RBRosemarie A Boland
Rosemarie A Boland
AMAtul Malhotra
Atul Malhotra
SDSusan M Donath
Susan M Donath
RBRisha Bhatia
Risha Bhatia

23 June 2021 in Archives of Disease in Childhood - Fetal and Neonatal Edition
Verified
Journal Article
Closed access
PDF file
RBRisha Bhatia
Risha Bhatia
HCHazel R Carlisle
Hazel R Carlisle
RARuth K Armstrong
Ruth K Armstrong
CKC Omar Farouk Kamlin
C Omar Farouk Kamlin
PDPeter Davis
Peter Davis
DTDavid G Tingay
David G Tingay
Objective: To evaluate the feasibility of electrical impedance tomography (EIT) to describe the regional tidal ventilation (VT) and change in end-expiratory lung volume (EELV) patterns in preterm infants during the process of extubation from invasive to non-invasive respiratory support. Design: Prospective observational study. Setting: Single-centre tertiary neonatal intensive care unit. Patients: Preterm infants born <32 weeks’ gestation who were being extubated to nasal continuous positive airway pressure as per clinician discretion. Interventions: EIT measurements were taken in supine infants during elective extubation from synchronised positive pressure ventilation (SIPPV) before extubation, during and then at 2 and 20 min after commencing nasal continuous positive applied pressure (nCPAP). Extubation and pressure settings were determined by clinicians. Main outcome measures: Global and regional ΔEELV and ΔVT, heart rate, respiratory rate and oxygen saturation were measured throughout. Results: Thirty infants of median (range) 2 (1, 21) days were extubated to a median (range) CPAP 7 (6, 8) cm H2O. SpO2/FiO2 ratio was a mean (95% CI) 50 (35, 65) lower 20 min after nCPAP compared with SIPPV. EELV was lower at all points after extubation compared with SIPPV, and EELV loss was primarily in the ventral lung (p=0.04). VT was increased immediately after extubation, especially in the central and ventral regions of the lung, but the application of nCPAP returned VT to pre-extubation patterns. Conclusions: EIT was able to describe the complex lung conditions occurring during extubation to nCPAP, specifically lung volume loss and greater use of the dorsal lung. EIT may have a role in guiding peri-extubation respiratory support.

19 October 2009 in Archives of Disease in Childhood - Fetal and Neonatal Edition
Verified
Journal Article
Closed access
PDF file
MTM Thió
M Thió
RBR Bhatia
R Bhatia
Jennifer DawsonJennifer Dawson
Jennifer Dawson
PDP G Davis
P G Davis
Background: Guidelines recommend avoidance of excessive oxygen administration during neonatal resuscitation. Blenders are used in some but not all hospitals. It has been suggested that self-inflating bags without a reservoir deliver around 40% oxygen and could be used to provide an inexpensive and effective technique of avoiding oxygen toxicity. Objective: To explore how much oxygen is delivered when using two different brands of neonatal self-inflating resuscitation bags without a reservoir. Methods: In a benchtop setting, the smallest non-disposable self-inflating bags from the Laerdal and Ambu ranges were tested. Oxygen concentration delivered by these devices under a variety of conditions was measured. 108 combinations of oxygen flow rates (10; 5 to 1 litre/min), ventilation rates (30, 60, 100 inflations/min) and peak inspiratory pressure ranges (20 to 25 cm H2O, 35 to 40 cm H2O or pop-off valve range, 55 to 60 cm H2O) were tested. Results: Delivered oxygen concentration varied depending on three parameters: gas flow rate, ventilatory rate and pressure. At a pressure of 20 to 25 cm H2O, mean oxygen concentration delivered by both bags exceeded 70% at any gas flow rate except for 1 litre/min (where delivered oxygen concentration was 60% to 70%). When the pop-off valve was opened at 35 to 40 cm H20, oxygen concentrations fell to 30% to 45% at gas flow rates ≤2 litres/min. The Ambu bag delivered a lower oxygen concentration than the Laerdal bag but this difference was not clinically important. Conclusion: When using the Laerdal and Ambu infant resuscitation self-inflating bags without a reservoir, delivered oxygen concentration is >70% for currently recommended flow and pressure settings.

3 October 2025 in Journal of Medical Internet Research
Verified
Journal Article
Open access
STSamantha Tudor
Samantha Tudor
RBRisha Bhatia
Risha Bhatia
MLMichael Liem
Michael Liem
TWTafheem Ahmad Wani
Tafheem Ahmad Wani
JBJames Boyd
James Boyd
UKUrooj Raza Khan
Urooj Raza Khan
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: The use of artificial intelligence (AI) in health care has been steadily increasing for over 2 decades. Integrating AI into neonatal intensive care units (NICUs) has promise as it has the potential to reshape neonatal care and improve outcomes. However, challenges such as data quality, clinical interpretation, and ethical considerations may hinder AI’s practical implementation in NICUs. Objective: This study aims (1) to analyze the current AI research landscape for predicting clinical outcomes and length of stay in the NICU and (2) to explore the benefits and challenges of using AI in the NICU for these predictions. Methods: A systematic review was conducted across 6 databases—PubMed, Embase, CINAHL, Cochrane Library, Informit, and La Trobe Library—to identify English-language peer-reviewed articles published between January 2017 and March 2023 that focused on the use of AI for predicting length of stay and clinical outcomes for NICU patients. Eligibility criteria excluded studies outside the NICU context or lacking predictive focus. Both prospective and retrospective designs were included. A thematic analysis of AI applications in NICUs from the articles identified was conducted. Results: A total of 24 studies were included in the review, comprising 15 retrospective and 9 prospective designs. These studies primarily originated from the United States (13 studies), with others from Austria, Taiwan, and other countries. The studies evaluated AI applications in NICU settings to predict comorbidities (18/24), mortality (4/24), and length of stay (2/24). Sixteen studies were in the exploration stage, lacking cohesive AI strategies, while 8 demonstrated systematic exploration but no fully integrated solutions. The synthesis of results identified key applications of AI in NICU care, including data-driven insights and predictive models, advancements in medical imaging, improved risk stratification, and personalized neonatal care. AI showed promise in enhancing diagnostic accuracy and care planning, but significant challenges persist, such as data quality, model generalization, and ethical concerns. No studies reported a fully integrated AI ecosystem, highlighting the need for further research to bridge gaps and realize AI’s transformative potential in neonatal care. Conclusions: This review highlights the potential of AI in improving NICU care, particularly through predictive models, medical imaging, and personalized interventions. However, the evidence is limited by significant methodological variability, small sample sizes, risk of bias, and a lack of external validation in included studies. Many studies remain in exploratory phases without cohesive AI strategies or integration into clinical practice, limiting the practical applicability of findings. These results underscore the importance of addressing challenges such as data quality, model generalization, and ethical considerations to fully realize AI’s potential in neonatal care. Future research should focus on robust validation, comprehensive implementation strategies, and ethical frameworks to ensure AI's effective and responsible integration into NICU settings. Trial Registration:

5 September 2019 in Neonatology
Verified
Journal Article
Closed access
PDF file
Arvind SehgalArvind Sehgal
Arvind Sehgal
RBRisha Bhatia
Risha Bhatia
CRCalum T. Roberts
Calum T. Roberts
Introduction: Surfactant replacement therapy through the endotracheal tube has been shown to improve lung compliance and reduce pulmonary pressures. Minimally invasive surfactant therapy (MIST) combines the benefits of continuous positive airway pressure (CPAP) and surfactant for spontaneously breathing preterm infants. We aimed to characterize the haemodynamic changes accompanying the first dose of MIST in preterm infants. Methods: Poractant alfa (200 mg/kg) was administered as MIST while on CPAP support. Echocardiograms were performed before (T1) and 30 (T2) and 60 min (T3) after MIST to assess serial change. Results: Twenty infants (mean gestational age 29.5 ± 2.8 weeks, median birth weight 1,102 g, IQR 840–1,940) received MIST at a median age of 16 h (IQR 3–24). FiO2 decreased significantly at 30 min (0.41 ± 0.08 to 0.27 ± 0.03, p < 0.001). Significant changes were noted at T2 for ductal parameters (decreased % time right to left shunt: 25% [15–33] to 14.5% [6–22], p = 0.013). Reduced pulmonary vascular resistance (PVR; increased pulmonary artery time velocity ratio 0.23 ± 0.05 to 0.28 ± 0.04 ms, p = 0.004) and improved longitudinal (tricuspid annular plane systolic excursion 4.5 ± 0.8 to 5.3 ± 0.9 mm, p = 0.004) and global (fractional area change 25 ± 2.3 vs. 27 ± 2%, p = 0.002) ventricular function were noted. Conclusions: This is the first study assessing cardiovascular adaptation to MIST, a procedure fast gaining acceptance in the neonatal community. Increased pulmonary blood flow is likely due to a combined effect of increased ductal flow, reduced PVR, and increased ventricular function.