Ajinkya J. Sonawane

Ajinkya J. Sonawane

Auto-generated profile, based on publicly available information

Ajinkya J. Sonawane

Discipline of Electrical Engineering, Indian Institute of Technology at Indore, Indore, India

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
ASAjinkya J. Sonawane
Ajinkya J. Sonawane
AUAmod C. Umarikar
Amod C. Umarikar
A virtual synchronous generator (VSG) is one of the promising solutions today for integration of renewable energy sources to the grid. Photovoltaic (PV) power generation is dominating most of the generation in renewable energy. In this scenario, it is imperative to study the combined dynamics of the PV source and the VSG in the grid connection mode. This article presents a study of such a PV power system, which is connected to a grid. The dc-link capacitor is considered as an energy storage (ES) element, which is generally the case in most of the practical systems. The synchronverter control scheme is taken as a VSG model. The small-signal model is obtained for the system under study, which mainly includes PV source and dc-link voltage controller dynamics. From the eigenvalues, which are obtained by using the small-signal model, analysis is carried out to find the effect on system dynamics due to the variation in different system parameters. Furthermore, the effect of maximum power point (MPP) and non-MPP modes on system dynamics is studied. The proposed model is validated through simulation in PSCAD/EMTDC and Controller Hardware In Loop (CHIL) in a Real Time Digital Simulator (RTDS).

16 May 2023 in IEEE Access
Verified
Journal Article
Open access
ASAjinkya J. Sonawane
Ajinkya J. Sonawane
AUAmod C. Umarikar
Amod C. Umarikar
This paper presents a synchronverter based photovoltaic (PV) system as STATCOM (PV-STATCOM), in which inverter exchanges active and reactive power with the grid. The proposed system provides reactive power compensation during daytime as well as nighttime. Additional operating modes for PV-STATCOM are proposed to enhance its capability. The proposed controller is compared with conventional control based PV-STATCOM on the basis of its performance with different tests. The key difference between conventional control and synchronverter is that synchronverter emulates inertia to control the frequency and voltage of the system. It is observed that the proposed system reduces frequency deviation and provides satisfactory regulation of the point of common coupling (PCC) voltage during full STATCOM mode and partial STATCOM mode. The low voltage ride through (LVRT) test is also performed on the proposed system. In the weak grid situation, the proposed PV-STATCOM performs in a more stable manner than the conventional PV-STATCOM in both reactive power and PCC voltage control mode. The study is performed on EMTDC/PSCAD simulation software. Real Time Control Hardware In Loop (CHIL) test is performed on Real Time Digital Simulator (RTDS) with a microcontroller to validate the proposed controller strategy and control design.

22 February 2022 in IEEE Access
Verified
Journal Article
Open access
ASAjinkya J. Sonawane
Ajinkya J. Sonawane
AUAmod C. Umarikar
Amod C. Umarikar
The performance of a grid forming inverter integrating solar PV/Wind farms with the grid is currently a topic of wide interest. Synchronverter control is one of the well-known grid forming converter techniques. Evaluation of synchronverter control in the benchmark system will help in understanding its operation when connected to a larger system. Therefore, this article investigates the performance of three phase single-stage photovoltaic (PV) system with a synchronverter control in the North American medium voltage (MV) benchmark system. The main objective is to conduct an exploratory study of the PV based synchronverter system when subjected to various disturbances. The modeling of PV array, controllers like synchronverter, dc-link voltage control, ac voltage control and their design is discussed in detail. The simulation studies for different cases are carried out by creating various disturbances like changes in solar radiation, temperature, load, faults, etc., in the benchmark system. Furthermore, under fault conditions, response with/without voltage droop mechanism in synchronverter is studied. All the offline simulations are carried out in PSCAD/EMTDC environment. Further, the real time test studies are validated on Controller-Hardware-In-Loop (CHIL) platform in Real-Time-Digital-Simulator (RTDS). From this simulation study, it is concluded that Synchronverter Control can be a viable option when used as a grid forming technique.