Amod C. Umarikar

Amod C. Umarikar

Auto-generated profile, based on publicly available information

Amod C. Umarikar

Department of Electrical Engineering, Indian Institute of Technology Indore, Indore, India

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2019 in Neurocomputing
Verified
Journal Article
Closed access
KTKarthik Thirumala
Karthik Thirumala
SPSushmita Pal
Sushmita Pal
TJTrapti Jain
Trapti Jain
AUAmod C. Umarikar
Amod C. Umarikar

8 September 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
ASAjinkya J. Sonawane
Ajinkya J. Sonawane
AUAmod C. Umarikar
Amod C. Umarikar
A virtual synchronous generator (VSG) is one of the promising solutions today for integration of renewable energy sources to the grid. Photovoltaic (PV) power generation is dominating most of the generation in renewable energy. In this scenario, it is imperative to study the combined dynamics of the PV source and the VSG in the grid connection mode. This article presents a study of such a PV power system, which is connected to a grid. The dc-link capacitor is considered as an energy storage (ES) element, which is generally the case in most of the practical systems. The synchronverter control scheme is taken as a VSG model. The small-signal model is obtained for the system under study, which mainly includes PV source and dc-link voltage controller dynamics. From the eigenvalues, which are obtained by using the small-signal model, analysis is carried out to find the effect on system dynamics due to the variation in different system parameters. Furthermore, the effect of maximum power point (MPP) and non-MPP modes on system dynamics is studied. The proposed model is validated through simulation in PSCAD/EMTDC and Controller Hardware In Loop (CHIL) in a Real Time Digital Simulator (RTDS).

16 May 2023 in IEEE Access
Verified
Journal Article
Open access
ASAjinkya J. Sonawane
Ajinkya J. Sonawane
AUAmod C. Umarikar
Amod C. Umarikar
This paper presents a synchronverter based photovoltaic (PV) system as STATCOM (PV-STATCOM), in which inverter exchanges active and reactive power with the grid. The proposed system provides reactive power compensation during daytime as well as nighttime. Additional operating modes for PV-STATCOM are proposed to enhance its capability. The proposed controller is compared with conventional control based PV-STATCOM on the basis of its performance with different tests. The key difference between conventional control and synchronverter is that synchronverter emulates inertia to control the frequency and voltage of the system. It is observed that the proposed system reduces frequency deviation and provides satisfactory regulation of the point of common coupling (PCC) voltage during full STATCOM mode and partial STATCOM mode. The low voltage ride through (LVRT) test is also performed on the proposed system. In the weak grid situation, the proposed PV-STATCOM performs in a more stable manner than the conventional PV-STATCOM in both reactive power and PCC voltage control mode. The study is performed on EMTDC/PSCAD simulation software. Real Time Control Hardware In Loop (CHIL) test is performed on Real Time Digital Simulator (RTDS) with a microcontroller to validate the proposed controller strategy and control design.

4 September 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
VTVinay K. Tiwari
Vinay K. Tiwari
AUAmod C. Umarikar
Amod C. Umarikar
TJTrapti Jain
Trapti Jain
This paper presents a measurement technique based on the undecimated wavelet packet transform (UWPT) and Hilbert transform (HT) to estimate power quality parameters at every sample. Thus, it results in improved time resolution and allows us to track the variation of power quality parameters with respect to time. The proposed technique consists of three stages. In the first stage, harmonics and fundamental components are separated from the distorted signal using UWPT. In the second stage, the Hilbert transform is used to extract the envelope of fundamental and harmonic components. In the last stage, power quality parameters are calculated at each instant according to IEEE Standard 1459-2010. The proposed scheme has been successfully implemented on the Xilinx Virtex-6 FPGA ML-605 evaluation kit. The simulation, as well as the experimental results demonstrate the effectiveness of the proposed method in terms of estimation accuracy, timing requirements and resource utilization.

22 February 2022 in IEEE Access
Verified
Journal Article
Open access
ASAjinkya J. Sonawane
Ajinkya J. Sonawane
AUAmod C. Umarikar
Amod C. Umarikar
The performance of a grid forming inverter integrating solar PV/Wind farms with the grid is currently a topic of wide interest. Synchronverter control is one of the well-known grid forming converter techniques. Evaluation of synchronverter control in the benchmark system will help in understanding its operation when connected to a larger system. Therefore, this article investigates the performance of three phase single-stage photovoltaic (PV) system with a synchronverter control in the North American medium voltage (MV) benchmark system. The main objective is to conduct an exploratory study of the PV based synchronverter system when subjected to various disturbances. The modeling of PV array, controllers like synchronverter, dc-link voltage control, ac voltage control and their design is discussed in detail. The simulation studies for different cases are carried out by creating various disturbances like changes in solar radiation, temperature, load, faults, etc., in the benchmark system. Furthermore, under fault conditions, response with/without voltage droop mechanism in synchronverter is studied. All the offline simulations are carried out in PSCAD/EMTDC environment. Further, the real time test studies are validated on Controller-Hardware-In-Loop (CHIL) platform in Real-Time-Digital-Simulator (RTDS). From this simulation study, it is concluded that Synchronverter Control can be a viable option when used as a grid forming technique.

11 July 2025 in IEEE Transactions on Consumer Electronics
Verified
Journal Article
Closed access
SMSiddhant Singh Maurya
Siddhant Singh Maurya
TJTrapti Jain
Trapti Jain
AUAmod C. Umarikar
Amod C. Umarikar
EPE S N Raju Paidi
E S N Raju Paidi
The growing penetration of Distributed Generators (DGs) results in a reduction of grid inertia. Low inertia poses significant challenges, particularly in the islanded mode of operation. To address this issue, one promising solution is to emulate the physical inertia of a synchronous generator in the power electronics control of the inverter. Among the various schemes proposed in the literature, a virtual synchronous generator (VSG) is well known. A VSG control provides inertia support by implementing the rotor dynamics of a synchronous machine in power electronics control. In VSGs, the average power obtained from the low pass filter (LPF) is used as feedback for the virtual torque equation. The cutoff frequency of the LPF limits bandwidth and decelerates dynamic response. To overcome this limitation, a compensator-based VSG has been proposed in this paper, which gives more flexibility in tuning the bandwidth of the controller. This reduces the tuning effort of controller gains in voltage and current control and improves small signal stability. Apart from the compensator, an additional damping loop is also included to suppress oscillations during disturbances. The small signal model (SSM) of the VSG was derived and incorporated into the microgrid model. The developed model was validated through eigenvalue analysis, time domain, and real-time simulations along with controller hardware in loop (CHIL) implementation. VSG-operated microgrid small signal stability was analyzed by feeding different types of loads like passive load, active load, and dynamic induction motor load. The effectiveness of VSG was established by comparing its performance with conventional droop control. The proposed VSG was found to outperform the conventional droop control in the presence of rectifier interfaced active load and constant power load.