Hydrofluorocarbons, currently used as refrigerants, in air-conditioning systems, for high-temperature heat pump systems in industrial applications are potent greenhouse gases. Their contribution to climate change is to increase. Future use of the hydrofluorocarbons as the hydrochlorofluorocarbons will be phased down. There are very different options to replace them and only a few pure fluids possess the combination of chemical, environmental, thermodynamic, and safety properties necessary for a working fluid. Low global warming potential refrigerants are anticipated to be the refrigerants of choice in industrial applications.
1 April 2020 in IOP Conference Series: Materials Science and Engineering
The article aims to consider a mathematical model of a compressor-condenser unit, based on the piston compressor with frequency control. The accepted initial data are temperatures and relative humidity of environment and a cooled room, geometrics of the main unit elements. CoolProp library was used for calculation of thermodynamic and thermophysical parameters. The flowchart of calculation of the compressor-condenser unit is provided in the article. The evaluation of the impact of change in environmental relative humidity on the heat transfer coefficient of the condenser has been made.
Since the 1987 Montreal Protocol, chlorinated refrigerants (CFCs and HCFCs) have been pointed out as responsible for the destruction of the ozone layer. The chemical industry has realized suitable replacement for CFC-12 and for HCFC-22 e.g. HFC-134a, HFC-404A, HFC-410A, HFC-507. This generation of refrigerants developed by the chemical industry can be characterized by the no ozone depleting potential and long atmospheric lifetime resulting in global warming potential. The contribution of the HFCs to the global warming brings up to discussion whether the HFCs should be considered as a transitional substance. Historically the use of natural and ecologically safe refrigerants was a strategy to eliminate environmental problems and avoid uncertainties with synthetic replacement fluids. Since ammonia is toxic, carbon dioxide provide high pressure, and the hydrocarbons are flammable, the general conclusion is often drawn that natural fluids gave safety problems. This paper will describe the possibilities of application as working fluids in low-temperature engineering refrigeration, heat pumping and organic Rankine cycles of the hydrofluoroolefins (HFOs) as third generation of synthetic working fluids.
1 November 2019 in Journal of Physics: Conference Series
Global warming and ozone depletion are leading effects attaching the consideration of environmental organizations. Conversion to alternative hydrofluorocarbons (HFC) refrigerants without chlorine atoms progressed over the last two decades. However recently because of the significant global warming impact of HFCs the hydrofluoroolefins (HFOs) were proposed as new generation alternative refrigerants. This article discussed fluorinated propene based isomers, summarizes refrigerant numbering scheme, flammability, fundamental parameters and thermodynamic properties of isomers containing five-, four- and three-fluorine atoms respectively. In the present study evaluated the refrigerant performance in an idealized vapor compression refrigeration cycle. Presented HFC and HFO blends as non-flammable refrigerants with relatively low global warming potential values.
1 January 2018 in Journal International Academy of Refrigeration
This paper presents an analysis and comparison of the energy and cost effectiveness of year-round liquid cooling systems that could be used in the climate of Saint Petersburg. An analysis of average monthly outdoor air temperatures over the past 10 years and the calculation of the seasonal energy performance ratio of a standard chiller and a chiller with an integrated free cooling system allowed to calculate the cost effectiveness of the free cooling technology. The study showed that a chiller with an integrated free cooling system has a significantly higher (by approximately 30%) seasonal energy performance ratio compared to a standard chiller. A cost estimate has confirmed that, despite higher initial capital costs, the free cooling system provides annual energy savings of approximately 1.5 million RUB. Economic benefits (return on additional investment) are already achieved in the first year of operation due to a significant reduction in operating costs. This study analyzes and provides design solutions for cooling systems based on real-life climate data for Saint Petersburg (average annual temperature = 7.1 °C) and the parameters of specific systems, enhansing the applicability of the findings in desiging energy-efficient systems in this region.