Babak Hassan Beygi

Babak Hassan Beygi

Auto-generated profile, based on publicly available information

Babak Hassan Beygi

Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2023 in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
Verified
Journal Article
Open access
PDF file
BBBabak Hassan Beygi
Babak Hassan Beygi
MWM. S. Wong
M. S. Wong
3D printing is considered as a helpful technology that facilitates innovative assistive technology, orthotics, and prosthetics development. This technology could likely contribute to positive treatment outcomes. It could also mitigate the challenges encountered when using the traditional methods. Our team’s research in the application of 3D printing in prosthetics, orthotics and biomedical technology has shown beneficial results in its use. This article gives a general description on application of CAD/CAM, digitalization and 3d printing in this industry followed by short description of two spinal-related projects conducted in our research team. Technological and clinical challenges on utilization of this technology have been listed. Finally, this manuscript provides recommendation for broader applications and developments of the aforementioned technology through interdisciplinary practices. A glimpse into the future of 3D printing in the healthcare industry shows that this industry is poised to continue having a significant impact in this sector. It should be emphasized that assistive technology, orthotics, and prosthetics require a human touch and connection, and no digital tool or technology can replace such requirements. Indeed, multi-disciplinary collaboration is the key to the success of applications of 3D printing. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/42225/32491 How To Cite: Hassan Beygi B, Wong M.S. Contemporary and future development of 3D printing technology in the field of assistive technology, orthotics and prosthetics. Canadian Prosthetics & Orthotics Journal. 2023; Volume 6, Issue 2, No.10. https://doi.org/10.33137/cpoj.v6i2.42225 Corresponding Author: M.S. WONG, PhDThe Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong.E-Mail: m.s.wong@polyu.edu.hkORCID ID: https://orcid.org/0000-0002-4157-9528

1 October 2023 in JBJS Reviews
Verified
Journal Article
Closed access
SLShan Liu
Shan Liu
LHLok Yi Ho
Lok Yi Ho
BBBabak Hassan Beygi
Babak Hassan Beygi
MWM. S. Wong
M. S. Wong
Background: Wearing spinal orthosis for 16 to 23 hours a day during the teenage years could be challenging and stressful for patients with adolescent idiopathic scoliosis (AIS). The investigation of clinical outcomes under various orthosis-wearing compliances can provide helpful insight into orthotic treatment dosage. This systematic review aims to investigate actual orthosis-wearing compliance and evaluate the effectiveness of orthotic treatment in controlling scoliotic curvature and preventing surgery for patients with AIS under various levels of orthosis-wearing compliance. Methods: A literature search of 7 electronic databases, namely PubMed, MEDLINE, Cochrane Library, Scopus, CINAHL Complete, Web of Science, and Embase, was conducted on May 19, 2023. Participant characteristics, orthotic treatment protocols, compliance information, outcome measures, and key findings were extracted. The Newcastle-Ottawa Scales were used to evaluate the quality of included cohort and case-control studies. Results: This study systematically reviewed 17 of 1,799 identified studies, including 1,981 subjects. The actual compliance was inconsistent and ranged from 7.0 to 18.8 hours daily. The proportion of compliant subjects in each study varied from 16.0% to 78.6% due to the heterogeneity of calculation period, measurement methods, and orthosis prescription time. Thirteen studies were investigated to determine the effectiveness of orthotic treatment in controlling curve deformity under different compliance groups, and 2 studies compared the compliance under different treatment outcomes. The rate of curve progression, defined as surpassing the measurement error threshold of 5° or 6° after orthotic treatment, varied from 1.8% to 91.7% across the studies. Ten studies defined the treatment failure, surgery, or surgery indication as Cobb angle progressing to a certain degree (e.g., 40°, 45°, or 50°) and reported failure/surgery/surgery indication rates ranging from 0.0% to 91.7% among different compliance level groups. Conclusion: This review found that the actual compliance with orthotic treatment was generally lower than the prescribed wearing time and exhibited wide variation among different studies. The electronic compliance monitors show promise in regular orthotic treatment practice. More importantly, the group with higher and consistent compliance has significantly less curve progression and lower surgery or failure rate than the group with lower and inconsistent compliance. Further studies are proposed to investigate the minimal orthosis-wearing compliance in patients with AIS treated with different types of orthoses. Level of Evidence: Level III, Systematic Review. See Instructions for Authors for a complete description of levels of evidence.

1 January 2019
Verified
Book Chapter
Closed access
MWMan Sang Wong
Man Sang Wong
BBBabak Hassan Beygi
Babak Hassan Beygi
YZYu Zheng
Yu Zheng

23 August 2023 in Prosthetics and Orthotics International
Verified
Journal Article
Closed access
BBBabak Hassan Beygi
Babak Hassan Beygi
ELEdmond Lou
Edmond Lou
SSSai Wing Sin
Sai Wing Sin
WKWing Kwan Kwok
Wing Kwan Kwok
HKHo Man Kee
Ho Man Kee
MWM. S. Wong
M. S. Wong
Background: The immediate in-orthosis correction of adolescent idiopathic scoliosis (AIS) is a useful prognostic parameter for the long-term orthotic treatment outcome. The 3-D clinical ultrasound technique is considered a noninvasive alternative to assess scoliotic deformities that could be applied in the orthotic treatment of AIS. Objective: This study aimed to investigate the feasibility of a purpose-design assessment frame in estimating biomechanical effects of the controlling pads of a spinal orthosis under the guidance of the ultrasound system. Methods: Twenty-six subjects with AIS were recruited and arranged to position inside the assessment frame, and controlling pads were applied strategically while the scoliotic deformities were assessed by clinical ultrasound to obtain at least 30% curvature correction, and the body shape was then captured using a computer-aided design and computer-aided manufacture system, and spinal orthoses were subsequently fabricated. The preorthosis and immediate in-orthosis coronal and sagittal X-rays were used for comparison. Results: X-ray assessments showed that the mean coronal Cobb angle and lumbar lordosis of the subjects from the preorthosis to immediate in-orthosis visits decreased significantly (p < 0.05) from 29.6° to 16.6°, and from 47.2° to 35.3°, respectively. Conclusions: This feasibility study showed that the proposed method would have a good potential to improve orthotic treatment outcome in a documented approach that should be considered for implementation into routine clinical practice aiming to reduce the chance of deformity deterioration leading to surgical intervention. However, a controlled group study is required to compare the results.

14 April 2022 in Prosthetics and Orthotics International
Verified
Journal Article
Closed access
MWM. S. Wong
M. S. Wong
HWHuidong Wu
Huidong Wu
BBBabak Hassan Beygi
Babak Hassan Beygi
QZQian Zhang
Qian Zhang
YLYangmin Lin
Yangmin Lin
ELEdmond Lou
Edmond Lou
Background: Hip protectors have been widely used for hip fracture prevention in the elderly, but its efficacy remains controversial. Users' compliance to hip protector is an important factor for its efficacy. However, the assessment of users' compliance tended to be subjective and unreliable in the past. Objectives: To quantify the elderly's compliance to hip protectors and investigate the effect of different underpant designs on the elderly's compliance. Study Design: A pilot randomized trial. Methods: Thirty-one participants were recruited and provided with hip protectors in which compliance monitors were installed and delivered with three pairs of either the conventional underpants or the purpose-design underpants randomly. Participants were encouraged to use the hip protectors with the assigned underpants for whole day. After 4 weeks, compliance data were downloaded from the compliance monitors. Participants were also asked to fill a survey form for acceptance analysis. The Spearman correlation coefficient and the Wilcoxon signed-rank test/2 independent samples t test/Mann-Whitney U test were used for the corresponding statistical analyses. Results: Thirty-one participants were recruited initially. Eighteen participants were excluded from instrumented compliance analysis because of limited or no data collection. The data of the resting 13 participants (six in the conventional underpants group and seven in purpose-design underpants group) were analyzed and showed an average instrumented compliance of 77.5% which was lower than the average self-reporting compliance (83.3%) of all the available 23 participants (eight of 31 became wheelchair-bounded). Participants' compliance was positively correlated with their acceptance to the hip protectors and significantly higher in the purpose-design underpants group than in the conventional underpants group (P < 0.05). Conclusions: This pilot study demonstrated a feasible protocol for compliance quantification of the elderly to the hip protectors, the importance to have an objective compliance measure to assess users' actual compliance, and purpose-design underpants could improve the users' compliance. Future studies with long-term observation and large sample size deserve further proof of the current findings.

2 December 2022 in Prosthetics and Orthotics International
Verified
Journal Article
Closed access
BBBabak Hassan Beygi
Babak Hassan Beygi
KWKubert Tianghang Wang
Kubert Tianghang Wang
HCHiu Lam Chan
Hiu Lam Chan
HWHui Dong Wu
Hui Dong Wu
PHPercy Ho Tim Hung
Percy Ho Tim Hung
MWMan Sang Wong
Man Sang Wong
Background: In this globalization era, institutions are developing strategies including international service-learning pedagogies to integrate global perspectives and dimensions into the learning and teaching processes to develop students' capacity in intercultural competence. Objective: This study aimed to assess the students' intercultural learning outcome through provision of orthotic community service to the less-privileged children. Methods: A Hong Kong–based university collaborated with 2 American universities to conduct an orthotic community service program for the children with cerebral palsy in mainland China. In the process of service delivery, the students with different backgrounds worked closely and students' professional knowledge, intercultural understanding, and communication skills were evaluated. A mixed-method approach was adopted to investigate on how this international program could facilitate meaningful interactions in clinical practices. Preprogram and postprogram surveys and focus group interviews were conducted. Statistical analyses were performed on the quantitative data, while interview data were analyzed thematically. Results: A comparison of preprogram and postprogram surveys showed that the students perceived this community service program important for enhancement of their capabilities to communicate with people from other cultures (n = 39, p < 0.05). It also showed an increase in local students' willingness to work with people from other cultures. Some themes related to intercultural competences were identified from the interview: “intercultural awareness, understanding, and communication” as well as openness to work/socialize with people from other cultures.” Conclusions: This study demonstrated that an international community service program could initiate positive changes in students' intercultural communication capability and interest to work with culturally different people.