31 October 2023 in Eastern-European Journal of Enterprise Technologies
This paper considers the deformation process of a typical section of a steel trunk pipeline with a defective zone, strengthened with a carbon fiber composite lining, under the influence of stationary internal pressure. Defects in the form of thinning of the pipe thickness and cracks were investigated. The stressed-strained state of the structure at critical pressure was analyzed. The thickness of the composite lining was determined, at which the bandage compensates for the effect of internal pressure on the damaged section of the pipeline. Research was carried out numerically based on finite element modeling in the ANSYS software package. When studying the stressed-strained state of a pipe with a defect of an arbitrary complex shape under the influence of critical pressure, a compensating value was obtained. The result showed that a carbon fiber lining with a thickness of 17 % of the rated thickness of the pipe could completely compensate for the effects of internal pressure in the defect area. In this case, the stresses in the carbon fiber lining were close to minimal. When studying the stressed-strained state of a pipe with a large crack of arbitrary shape at critical pressure, a compensating value was also obtained. It has been established that to compensate for the concentration of internal pressure in the crack zone, the thickness of the composite lining should be at the level of 34 % of the rated thickness of the pipe. In this case, the deformation of the steel pipe in the area of the crack occurs in the elastic region. The exception is the crack tips, where plastic deformations are observed, and stresses arise up to 93 % of the ultimate strength of the pipe steel. At the same time, the stresses in the carbon fiber lining remain close to minimal. Thus, it is recommended to use carbon fiber linings with a thickness of 17 % or more of the rated pipe thickness to bandage damage constituting up to 75 % of the thickness of a steel pipe. To bandage cracks, it is recommended to use carbon fiber linings with a thickness of at least 34 % of the rated pipe thickness
25 November 2024 in Technobius
The study presents the treatment of soil with chitosan and xanthan gum, examines the influence of the pH of base solutions on the solubility and activity of these biopolymers, and investigates the changes in soil properties resulting from their application. The first stage of the study is devoted to the peculiarities of preparing soil reinforcement with biopolymers and their mixing process. The obtained samples were analyzed for their texture, which allowed identifying the optimal conditions for maximum solubility. The second stage of the study is devoted to evaluating the modified soil's behavior under wetting conditions. The moisture level of the soil directly affects its physical and mechanical properties. Understanding these changes makes it possible to predict the behavior of the soil under different service conditions. The study considered 10 soil samples prepared with base solutions of different acidity (pH 4, pH 7, pH 9), among which one sample serves as a control sample without modification with biopolymers. This makes it possible to evaluate the effect of modification on soil properties and to identify optimal conditions for its use. The analysis showed that the solutions' moisture level and acidity significantly affect the samples' structural characteristics. At the same time modified soils show improved performance compared to the control sample, the sample reinforced with chitosan increased density by 16 %. These data are important for the development of effective solutions in geotechnical and construction engineering.