Senthilkumar Subramaniam

Senthilkumar Subramaniam

Auto-generated profile, based on publicly available information

Senthilkumar Subramaniam

Department of Electrical and Electronics Engineering, National Institute of Technology, Tiruchirappalli, India

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
IAI. Anand
I. Anand
SSSubramaniam Senthilkumar
Subramaniam Senthilkumar
DBDipankar Biswas
Dipankar Biswas
MKM. Kaliamoorthy
M. Kaliamoorthy
This paper presents a dynamic power flow management system for a solar PV system employing a single stage single inductor based dual input/output DC-DC converter feeding standalone DC loads backed up by a rechargeable battery. A time sharing voltage mode control scheme has been proposed for power flow management between solar PV, battery and standalone DC load and also it maintains a constant DC load voltage and performs MPPT operation of solar PV. The implementation of the control scheme has been described in detail. The steady state performance of the single stage converter has been explained with the relevant analytical expressions derived along with the characteristics. A state space average model was developed for simulating the transient behaviour and validating the working of the system for step changes in the input solar PV power and the DC loads. A hardware prototype of the proposed system has been fabricated and the proposed controller have been implemented using dSPACE DS1103 Real Time Interface(RTI) board. The working of the proposed scheme for the different levels of input solar insolation and DC Load power demand has been satisfactorily demonstrated and the corresponding results are also provided.

1 November 2016 in Journal of Renewable and Sustainable Energy
Verified
Journal Article
Closed access
SSSarojini Mary Samikannu
Sarojini Mary Samikannu
RNRakesh Namani
Rakesh Namani
SSSenthil Kumar Subramaniam
Senthil Kumar Subramaniam
This paper proposes a new static reconfiguration technique to configure the modules in the Photo-Voltaic (PV) array so as to enhance the generated power from the array under partial shading conditions. In this approach, the physical location of the modules in a Total Cross Tied (TCT) connected PV array is arranged based on the Magic Square (MS) pattern so as to distribute the shading effect over the entire array. Further, this arrangement of modules is done without altering the electrical connection of the modules in the array. The MS arrangement reduces the effect of shading of modules in any row thereby enhancing the generated PV power. The MS pattern based PV array configuration has only one Global Maximum Power Point at the right most peak in the PV curve as compared to the conventional TCT configuration under partially shaded conditions. Thus, the proposed MS scheme evidently avoids the need for complex Maximum-Power-Point-Tracking algorithms. The performance of the system is investigated for different shading patterns and the results show that positioning the modules of the array according to MS pattern provides improved performance under partially shaded conditions.

1 September 2018 in Journal of Renewable and Sustainable Energy
Verified
Journal Article
Closed access
PDF file
GMGurusamy Madhusudanan
Gurusamy Madhusudanan
SSSubramaniam Senthilkumar
Subramaniam Senthilkumar
IAI. Anand
I. Anand
Sanjeevikumar PadmanabanSanjeevikumar Padmanaban
Sanjeevikumar Padmanaban
Partial shading in a solar array deteriorates the maximum power generated owing to the voltage mismatch and current mismatch of the shaded solar PV module. Also, partial shading primes to multiple peaks in the P-V characteristics of the solar PV array and it has become more complex to track the Maximum Power Point (MPP). To enhance the maximum power generated by means of reducing mismatch losses, several reconfiguration techniques were suggested earlier. The mismatch losses depend not only on the amount of the area shaded but also on the shading pattern and array arrangement. This paper proposes a new pattern of positioning the PV module using the Latin square pattern without changing the total cross tied electrical connection. The proposed pattern disperses the shading uniformly within the given PV array which reduces mismatch losses significantly and increases the generation of power. The shade dispersion using proposed pattern also eliminates multiple peaks in its PV curve which enables the use of a simple algorithm to track MPP. This Latin square pattern is studied under different partial shading conditions, and the results exhibit improved performance under partial shading conditions.

1 July 2015 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
SKSubramaniam Senthil Kumar
Subramaniam Senthil Kumar
NKNatarajan Kumaresan
Natarajan Kumaresan
MSMuthiah Subbiah
Muthiah Subbiah
A system consisting of a capacitor‐excited induction generator (CEIG) with associated power electronic converters has been developed for supplying power to a micro‐grid. The power fed to the grid from the CEIG is controlled using a diode bridge rectifier (DBR) and a pulse width modulated (PWM) inverter, connected between the generator terminals and the grid. A simple analog based hysteresis current control (HCC) technique has been employed in which the current control of the PWM inverter alone needs to be carried out by sensing the current and voltage at the grid terminals. The successful working of the system has been demonstrated for three different patterns of feeding power to a micro‐grid, by experiments conducted on a three‐phase 230 V, 3.7 kW CEIG, with a 100 µF delta connected excitation capacitor bank and employing the controllers fabricated in the laboratory. The grid power is represented as an equivalent load resistance in the steady‐state equivalent circuit of the CEIG and the technique of genetic algorithm (GA) has been adopted for the analysis of the proposed system. The predetermined performance characteristics of the system and the results of Matlab/Simulink simulation studies have also been presented.

24 July 2020 in International Journal of Emerging Electric Power Systems
Verified
Journal Article
Open access
PDF file
NRNamani Rakesh
Namani Rakesh
SBSanchari Banerjee
Sanchari Banerjee
SSSenthilkumar Subramaniam
Senthilkumar Subramaniam
NBNatarajan Babu
Natarajan Babu
The foremost problem facing by the photovoltaic (PV) system is to identify the faults and partial shade conditions. Further, the power loss can be avoided by knowing the number of faulty modules and strings. Hence, to attend these problems, a new method is proposed to differentiate the faults and partially shaded conditions along with the number of mismatch modules and strings for a dynamic change in irradiation. The proposed method has developed in two main steps based on a simple observation from the Current versus Voltage (I-V) characteristic curve of PV array at Line-Line (LL) fault. First, the type of fault is detected using defined variables, which are continuously updated from PV array voltage, current, and irradiation. Second, it gives the number of mismatch modules (or short-circuited bypass diodes) and mismatch strings (or open-circuited blocking diodes) by comparing with the theoretical predictions from the I-V characteristic curve of PV array. The proposed algorithm has been validated both on experimentation using small scale grid-connected PV array developed in the laboratory as well as MATLAB/Simulink simulations. Further, the comparative assessment with existing methods is presented with various performance indices to show the effectiveness of the proposed algorithm.

1 March 2023 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
SUShanmuganathan U.
Shanmuganathan U.
SKSaket K.
Saket K.
SKS. Senthil Kumar
S. Senthil Kumar
MDM. K. Das
M. K. Das
SNS. Nekkanti
S. Nekkanti
VNV. Nallasamy
V. Nallasamy
A 500 kV, 80 Hz repetition rate compact Marx generator has been designed and developed for producing high intense relativistic electron beams for high-power microwave (HPM) sources. This Marx generator comprises eight bipolar stages (16 stages of unipolar) using energy storage capacitors for achieving improved performance in repetition mode operation. The maximum charging voltage per stage is 50 kV, producing an erected voltage of 800 kV. However, the load voltage will vary according to the impedance of the load connected across the generator. Custom-designed energy storage capacitors were developed to allow voltage reversal of up to 30%–50%, enabling the system to deliver a higher current. A small pulse transformer-based triggering unit with an output voltage of 30 kV was used for triggering the generator. The system’s performance was tested in pulse repetition frequency (PRF) mode with resistive and diode loads and achieved a repetition rate of 80 Hz. An energy density of ~460 J/m3 was achieved in the developed system. A vircator device was connected and tested to benchmark the Marx generator for its repetitive and burst mode operations. The test results show the measured RF output power of 100 MW.