Paloma Grau

Paloma Grau

Auto-generated profile, based on publicly available information

Paloma Grau

CEIT and Tecnun (University of Navarra), Manuel de Lardizábal 15, 20018 San Sebastián, Spain

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2017 in Water Research
Verified
Journal Article
Open access
Tamara Fernández ArévaloTamara Fernández Arévalo
Tamara Fernández Arévalo
ILI. Lizarralde
I. Lizarralde
FFF. Fdz-Polanco
F. Fdz-Polanco
SPS.I. Pérez-Elvira
S.I. Pérez-Elvira
JGJ.M. Garrido
J.M. Garrido
EAE. Ayesa
E. Ayesa
The growing development of technologies and processes for resource treatment and recovery is offering endless possibilities for creating new plant-wide configurations or modifying existing ones. However, the configurations' complexity, the interrelation between technologies and the influent characteristics turn decision-making into a complex or unobvious process. In this frame, the Plant-Wide Modelling (PWM) library presented in this paper allows a thorough, comprehensive and refined analysis of different plant configurations that are basic aspects in decision-making from an energy and resource recovery perspective. In order to demonstrate the potential of the library and the need to run simulation analyses, this paper carries out a comparative analysis of WWTPs, from a techno-economic point of view. The selected layouts were (1) a conventional WWTP based on a modified version of the Benchmark Simulation Model No. 2, (2) an upgraded or retrofitted WWTP, and (3) a new Wastewater Resource Recovery Facilities (WRRF) concept denominated as C/N/P decoupling WWTP. The study was based on a preliminary analysis of the organic matter and nutrient energy use and recovery options, a comprehensive mass and energy flux distribution analysis in each configuration in order to compare and identify areas for improvement, and a cost analysis of each plant for different influent COD/TN/TP ratios. Analysing the plants from a standpoint of resources and energy utilization, a low utilization of the energy content of the components could be observed in all configurations. In the conventional plant, the COD used to produce biogas was around 29%, the upgraded plant was around 36%, and 34% in the C/N/P decoupling WWTP. With regard to the self-sufficiency of plants, achieving self-sufficiency was not possible in the conventional plant, in the upgraded plant it depended on the influent C/N ratio, and in the C/N/P decoupling WWTP layout self-sufficiency was feasible for almost all influents, especially at high COD concentrations. The plant layouts proposed in this paper are just a sample of the possibilities offered by current technologies. Even so, the library presented here is generic and can be used to construct any other plant layout, provided that a model is available.


1 September 2012 in Water Science & Technology
Verified
Journal Article
Closed access
PDF file
DBDamien Batstone
Damien Batstone
YAYouri Amerlinck
Youri Amerlinck
GEGeorge Ekama
George Ekama
RGRajeev Goel
Rajeev Goel
PGPaloma Grau
Paloma Grau
EVEveline Volcke
Eveline Volcke
Process models used for activated sludge, anaerobic digestion and in general wastewater treatment plant process design and optimization have traditionally focused on important biokinetic conversions. There is a growing realization that abiotic processes occurring in the wastewater (i.e. ‘solvent’) have a fundamental effect on plant performance. These processes include weak acid–base reactions (ionization), spontaneous or chemical dose-induced precipitate formation and chemical redox conversions, which influence pH, gas transfer, and directly or indirectly the biokinetic processes themselves. There is a large amount of fundamental information available (from chemical and other disciplines), which, due to its complexity and its diverse sources (originating from many different water and process environments), cannot be readily used in wastewater process design as yet. This position paper outlines the need, the methods, available knowledge and the fundamental approaches that would help to focus the effort of research groups to develop a physicochemical framework specifically in support of whole-plant process modeling. The findings are that, in general, existing models such as produced by the International Water Association for biological processes are limited by omission of key corrections such as non-ideal acid–base behavior, as well as major processes (e.g., ion precipitation). While the underlying chemistry is well understood, its applicability to wastewater applications is less well known. This justifies important further research, with both experimental and model development activities to clarify an approach to modeling of physicochemical processes.

1 November 2007 in Water Research
Verified
Journal Article
Closed access
PGP. Grau
P. Grau
MGM. de Gracia
M. de Gracia
Peter VanrolleghemPeter Vanrolleghem
Peter Vanrolleghem
EAE. Ayesa
E. Ayesa

4 March 2019 in International Journal of Productivity and Performance Management
Verified
Journal Article
Closed access
Andres Muñoz-VillamizarAndres Muñoz-Villamizar
Andres Muñoz-Villamizar
JSJavier Santos
Javier Santos
JGJulio J. Garcia-Sabater
Julio J. Garcia-Sabater
Alvaro LleoAlvaro Lleo
Alvaro Lleo
PGPaloma Grau
Paloma Grau
Purpose: The purpose of this paper is to introduce a new methodology called overall greenness performance for value stream mapping (OGP-VSM). Using value-added concepts, this approach has the potential to integrate, measure, control and improve productive and environmental performance in accordance with a company’s context.Design/methodology/approach: The OGP-VSM approach was developed by reviewing and integrating the environmental aspects of existing lean thinking tools and approaches.Findings: This research revealed the lack of practical integration between productive and environmental performance. Using OGP-VSM, managers can see that environmental practices have a direct impact on productivity. OGP-VSM allows a balance to be found between lean and green practices in order to achieve the simultaneous improvement of productivity and environmental performance.Practical implications: The proposed approach is applied to a case study in an automotive company in Spain and lays the groundwork for moving toward functional environmental sustainability in manufacturers.Originality/value: Companies are increasingly implementing environmentally focused practices. Pursuing environmentally friendly (green) performance poses several challenges, but it also affords opportunities to create new methodologies for generating a competitive advantage for manufacturing companies. There are a limited number of approaches to drawing together the elements and attributes that are essential for a holistic, practical and long-lasting improvement of environmental performance in the manufacturing sector.

1 February 2006 in Water Science & Technology
Verified
Journal Article
Closed access
PDF file
EAE. Ayesa
E. Ayesa
ASA. De la Sota
A. De la Sota
PGP. Grau
P. Grau
JSJ.M. Sagarna
J.M. Sagarna
ASA. Salterain
A. Salterain
JSJ. Suescun
J. Suescun
This paper presents the theoretical basis and the main results obtained during the development and full-scale experimental validation of the new supervisory control strategy designed for the Galindo-Bilbao wastewater treatment plant (WWTP). The different phases of the project have been carried out over the last 8 years, combining model simulations, pilot-plant experimentation and full-scale validation. The final control strategy combines three complementary control loops to optimise the nitrogen removal in pre-denitrifying activated sludge plants. The first controller was designed to maintain the average concentration of the ammonia in the effluent via the automatic selection of the most appropriate DO set point in the aerobic reactors. The second control loop optimises the use of the denitrification potential and finally, the third control loop maintains the selected amount of biomass in the biological reactors by automatic manipulation of the wastage rate. Mobile-averaged windows have been implemented to incorporate commonly used averaged values in the control objectives. The performance of the controllers has been successfully assessed through the full-scale experimental validation in one of the lines of the WWTP.