11 April 2024 in Optical Materials Express
Two-dimensional (2D) MXene has recently been found to play a significant role in constructing biosensing platforms due to its excellent biocompatibility, large specific surface area, and broad optical absorption. In this article, an ultra-sensitive refractive index (RI) sensor based on an optical microfiber coupler (OMC) coated with Ti3C2 MXene is proposed and experimentally demonstrated. Numerical results reveal that surface modification of MXene enhances the RI sensitivity of OMC and creates a new artificial dispersion turning point (ADTP). The OMC with a dispersion turning point (DTP) at 1300 nm is fabricated using a hybrid fusion elongation-wet etching method. It has a waist width of approximately 2.46 µm. We experimentally achieved the RI sensitivity of 9.1 × 104 ± 0.42 × 104 nm/RIU using the OMC. MXene improves the sensitivity of the OMC because Ti3C2 MXene can change the effective refractive index (ERI) for both the even and odd modes, leading to the interference dips shifting closer to the DTP. The experimental results demonstrate that the RI sensitivity of the OMC coated with Ti3C2 MXene can reach -1.7 × 105 ± 0.2 × 105 nm/RIU, which shows a ∼87% sensitivity boost compared with bare OMC. The proposed sensor is expected to be used for high-sensitivity biochemical molecule detection.
25 November 2024 in IEEE Transactions on Instrumentation and Measurement
We propose and demonstrate a dual microfiber (DMF) interferometric sensor here. The DMF can be fabricated from standard single-mode optical fibers by using a two-step process. First, we punch a hole through the fiber side-on via femtosecond laser machining, and then, we thermally taper the perforated fiber region, resulting in two parallel microfibers. We systematically investigated the refractive index (RI) sensing performance from both theoretical and experimental aspects. The simulation results show that a DMF sensor with waist widths of 2.6 and $2.7~\mu $ m achieves a high sensitivity of 11000 nm/RIU in the low RI range of 1.3330–1.3360, which is much higher than that of conventional optical fiber RI sensors. We further experimentally examined the sensing capability of the DMF sensor, achieving a high RI sensitivity of 10442.4 nm/RIU within the RI range of 1.3330–1.3360, which agrees well with theoretical results. We also investigated the RI and temperature cross-sensitivity of the DMF sensor, achieving a result of $- 1.48\times 10^{-4}$ RIU/°C. The DMF sensor offers advantages such as ease of fabrication, ultrahigh RI sensitivity, and compact size, demonstrating the significant potential for applications in clinical testing, biomolecular diagnostics, and food safety.