Haiyang Yu

Dr. Haiyang Yu


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZSZeyuan Song
Zeyuan Song
RPRui Peng
Rui Peng
HYHaiyang Yu
Haiyang Yu
GGGuanqiu Guo
Guanqiu Guo
Kaiwei LiKaiwei Li
Kaiwei Li
YWYihui Wu
Yihui Wu
We propose and demonstrate a dual microfiber (DMF) interferometric sensor here. The DMF can be fabricated from standard single-mode optical fibers by using a two-step process. First, we punch a hole through the fiber side-on via femtosecond laser machining, and then, we thermally taper the perforated fiber region, resulting in two parallel microfibers. We systematically investigated the refractive index (RI) sensing performance from both theoretical and experimental aspects. The simulation results show that a DMF sensor with waist widths of 2.6 and $2.7~\mu $ m achieves a high sensitivity of 11000 nm/RIU in the low RI range of 1.3330–1.3360, which is much higher than that of conventional optical fiber RI sensors. We further experimentally examined the sensing capability of the DMF sensor, achieving a high RI sensitivity of 10442.4 nm/RIU within the RI range of 1.3330–1.3360, which agrees well with theoretical results. We also investigated the RI and temperature cross-sensitivity of the DMF sensor, achieving a result of $- 1.48\times 10^{-4}$ RIU/°C. The DMF sensor offers advantages such as ease of fabrication, ultrahigh RI sensitivity, and compact size, demonstrating the significant potential for applications in clinical testing, biomolecular diagnostics, and food safety.

10 April 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
HYHaiyang Yu
Haiyang Yu
WYwang yue
wang yue
YXYang Xu
Yang Xu
Wenchao ZhouWenchao Zhou
Wenchao Zhou
YWYihui Wu
Yihui Wu
Optical microfiber biosensors demonstrate exceptionally ultra-high sensitivity at the dispersion turning point (DTP). However, the DTP is highly susceptible to variations in dimensional and external environmental factors, and the spectral response is mismatched from preparation in air to application in a liquid environment, making the DTP difficult to control effectively. In this work, we propose a method that bridges the relationship between the interference spectra of air and aqueous environments. By counting the interference peaks in air, we can accurately predict the DTP position in liquids. Meanwhile, it provides a new balance between sensitivity and wide linear dynamic range, achieving wide dynamic range detection across various concentrations. The optical microfiber coupler (OMC) is fabricated using the hydrogen–oxygen flame melting tapering method. In addition, the concentration, temperature, and solvent used for the sensor’s biofunctional layer are optimized. Finally, in refractive index sensing, a maximum sensitivity of 1.17 × 105 ± 0.038 × 105 nm/RIU is achieved. For biosensing, a wide dynamic range detection of cardiac troponin I (cTnI) is realized at concentrations of 12–48 ng/mL, 120–480 pg/mL, and 120–480 fg/mL.