Vimal Prabhu Pandiyan

Vimal Prabhu Pandiyan

Auto-generated profile, based on publicly available information

Vimal Prabhu Pandiyan

Department of Ophthalmology, University of Washington, Seattle, WA 98109, USA

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2020 in Science Advances
Verified
Journal Article
Open access
PDF file
VPVimal Prabhu Pandiyan
Vimal Prabhu Pandiyan
AMAiden Maloney-Bertelli
Aiden Maloney-Bertelli
JKJames Kuchenbecker
James Kuchenbecker
KBKevin C. Boyle
Kevin C. Boyle
TLTong Ling
Tong Ling
RSRamkumar Sabesan
Ramkumar Sabesan
Human cone photoreceptors undergo rapid nanometer-scale mechanical deformations during the first step of phototransduction.

26 August 2020 in Biomedical Optics Express
Verified
Journal Article
Closed access
VPVimal Prabhu Pandiyan
Vimal Prabhu Pandiyan
XJXiaoyun Jiang
Xiaoyun Jiang
AMAiden Maloney-Bertelli
Aiden Maloney-Bertelli
JKJames Kuchenbecker
James Kuchenbecker
USUtkarsh Sharma
Utkarsh Sharma
RSRamkumar Sabesan
Ramkumar Sabesan
Optoretinography–the non-invasive, optical imaging of light-induced functional activity in the retina–stands to provide a critical biomarker for testing the safety and efficacy of new therapies as well as their rapid translation to the clinic. Optical phase change in response to light, as readily accessible in phase-resolved OCT, offers a path towards all-optical imaging of retinal function. However, typical human eye motion adversely affects phase stability. In addition, recording fast light-induced retinal events necessitates high-speed acquisition. Here, we introduce a high-speed line-scan spectral domain OCT with adaptive optics (AO), aimed at volumetric imaging and phase-resolved acquisition of retinal responses to light. By virtue of parallel acquisition of an entire retinal cross-section (B-scan) in a single high-speed camera frame, depth-resolved tomograms at speeds up to 16 kHz were achieved with high sensitivity and phase stability. To optimize spectral and spatial resolution, an anamorphic detection paradigm was introduced, enabling improved light collection efficiency and signal roll-off compared to traditional methods. The benefits in speed, resolution and sensitivity were exemplified in imaging nanometer-millisecond scale light-induced optical path length changes in cone photoreceptor outer segments. With 660 nm stimuli, individual cone responses readily segregated into three clusters, corresponding to long, middle, and short-wavelength cones. Recording such optoretinograms on spatial scales ranging from individual cones, to 100 µm-wide retinal patches offers a robust and sensitive biomarker for cone function in health and disease.

1 October 2020 in Biophysical Journal
Verified
Journal Article
Closed access
KBK.C. Boyle
K.C. Boyle
ZCZhijie Charles Chen
Zhijie Charles Chen
TLT. Ling
T. Ling
VPV.P. Pandiyan
V.P. Pandiyan
JKJ. Kuchenbecker
J. Kuchenbecker
DPD. Palanker
D. Palanker

19 September 2022 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
VPVimal Prabhu Pandiyan
Vimal Prabhu Pandiyan
PNPhuong T. Nguyen
Phuong T. Nguyen
EPEdward N. Pugh
Edward N. Pugh
RSRamkumar Sabesan
Ramkumar Sabesan
Human cone outer segment (COS) length changes in response to stimuli bleaching up to 99% of L- and M-cone opsins were measured with high resolution, phase-resolved optical coherence tomography (OCT). Responses comprised a fast phase (∼5 ms), during which COSs shrink, and two slower phases (1.5 s), during which COSs elongate. The slower components saturated in amplitude (∼425 nm) and initial rate (∼3 nm ms −1 ) and are well described over the 200-fold bleaching range as the sum of two exponentially rising functions with time constants of 80 to 90 ms (component 1) and 1,000 to 1,250 ms (component 2). Measurements with adaptive optics reflection densitometry revealed component 2 to be linearly related to cone pigment bleaching, and the hypothesis is proposed that it arises from cone opsin and disk membrane swelling triggered by isomerization and rate-limited by chromophore hydrolysis and its reduction to membrane-localized all-trans retinol. The light sensitivity and kinetics of component 1 suggested that the underlying mechanism is an osmotic response to an amplified soluble by-product of phototransduction. The hypotheses that component 1 corresponds to G-protein subunits dissociating from the membrane, metabolites of cyclic guanosine monophosphate (cGMP) hydrolysis, or by-products of activated guanylate cyclase are rejected, while the hypothesis that it corresponds to phosphate produced by regulator of G-protein signaling 9 (RGS9)-catalyzed hydrolysis of guanosine triphosphate (GTP) in G protein–phosphodiesterase complexes was found to be consistent with the results. These results provide a basis for the assessment with optoretinography of phototransduction in individual cone photoreceptors in health and during disease progression and therapeutic interventions.

27 August 2021 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
VPVimal Prabhu Pandiyan
Vimal Prabhu Pandiyan
XJXiaoyun Jiang
Xiaoyun Jiang
JKJames Kuchenbecker
James Kuchenbecker
RSRamkumar Sabesan
Ramkumar Sabesan
Line-scan OCT incorporated with adaptive optics (AO) offers high resolution, speed, and sensitivity for imaging retinal structure and function in vivo. Here, we introduce its implementation with reflective mirror-based afocal telescopes, optimized for imaging light-induced retinal activity (optoretinography) and weak retinal reflections at the cellular scale. A non-planar optical design was followed based on previous recommendations with key differences specific to a line-scan geometry. The three beam paths fundamental to an OCT system –illumination/sample, detection, and reference– were modeled in Zemax optical design software to yield theoretically diffraction-limited performance over a 2.2 deg. field-of-view and 1.5 D vergence range at the eye’s pupil. The performance for imaging retinal structure was exemplified by cellular-scale visualization of retinal ganglion cells, macrophages, foveal cones, and rods in human observers. The performance for functional imaging was exemplified by resolving the light-evoked optical changes in foveal cone photoreceptors where the spatial resolution was sufficient for cone spectral classification at an eccentricity 0.3 deg. from the foveal center. This enabled the first in vivo demonstration of reduced S-cone (short-wavelength cone) density in the human foveola, thus far observed only in ex vivo histological preparations. Together, the feasibility for high resolution imaging of retinal structure and function demonstrated here holds significant potential for basic science and translational applications.

24 October 2022 in Biomedical Optics Express
Verified
Journal Article
Closed access
XJXiaoyun Jiang
Xiaoyun Jiang
TLTeng Liu
Teng Liu
VPVimal Prabhu Pandiyan
Vimal Prabhu Pandiyan
ESEmily Slezak
Emily Slezak
RSRamkumar Sabesan
Ramkumar Sabesan
Optoretinography (ORG) has the potential to be an effective biomarker for light-evoked retinal activity owing to its sensitive, objective, and precise localization of retinal function and dysfunction. Many ORG implementations have used adaptive optics (AO) to localize activity on a cellular scale. However, the use of AO restricts field-of-view (FOV) to the isoplanatic angle, necessitating the montaging of multiple regions-of-interest to cover an extended field. In addition, subjects with lens opacities, increased eye movements and decreased mobility pose challenges for effective AO operation. Here, we developed a coarse-scale ORG (CoORG) system without AO, which accommodates FOVs up to 5.5 deg. in a single acquisition. The system is based on a line-scan spectral domain OCT with volume rates of up to 32 Hz (16,000 B-frames per second). For acquiring ORGs, 5.5 deg. wide OCT volumes were recorded after dark adaptation and two different stimulus bleaches. The stimulus-evoked optical phase change was calculated from the reflections encasing the cone outer segments and its variation was assessed vs. eccentricity in 12 healthy subjects. The general behavior of ΔOPL vs. time mimicked published reports. High trial-to-trial repeatability was observed across subjects and with eccentricity. Comparison of ORG between CoORG and AO-OCT based ORG at 1.5°, 2.5°, and 3.5° eccentricity showed an excellent agreement in the same 2 subjects. The amplitude of the ORG response decreased with increasing eccentricity. The variation of ORG characteristics between subjects and versus eccentricity was well explained by the photon density of the stimulus on the retina and the outer segment length. Overall, the high repeatability and rapid acquisition over an extended field enabled the normative characterization of the cone ORG response in healthy eyes, and provides a promising avenue for translating ORG for widespread clinical application.