Johannes Oltmanns

Johannes Oltmanns

Auto-generated profile, based on publicly available information

Johannes Oltmanns

Institute for Technical Thermodynamics Technische Universität Darmstadt Darmstadt Germany

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2020 in Energy Science & Engineering
Verified
Journal Article
Open access
PDF file
JOJohannes Oltmanns
Johannes Oltmanns
DSDavid Sauerwein
David Sauerwein
FDFrank Dammel
Frank Dammel
PSPeter Stephan
Peter Stephan
CKChristoph Kuhn
Christoph Kuhn
The electric energy demand of data centers in Germany has grown rapidly from 10.5 TWh/a in 2010 to 13.2 TWh/a in 2017, an average of 25% of which are used to fulfill the data centers' cooling demand. In order to increase its energy efficiency, TU Darmstadt applies a new cooling concept in the next generation of its high‐performance computing data center “Lichtenberg II.” Instead of the current air‐cooled servers with water‐cooled rear doors at 17‐24°C, the new data center will be equipped with direct hot‐water cooling for the high‐performance computer, supplying heat at a temperature of 45°C. The high‐temperature waste heat is used for heating purposes on the university's campus Lichtwiese. For waste heat utilization, two concepts are presented, either integrating the heat in the return line of the district heating network or using it locally in buildings located near the data center. Reductions in CO2 emission and annuity are generated both by decreased compression cooling demand for the data center and by decreased heat generation due to waste heat utilization. Depending on the scenario, a total of 20%‐50% of the waste heat emitted by the high‐performance computer can be used for heating purposes, while the remaining heat is dissipated efficiently via free cooling without additional energy demand for mechanical chillers. CO2 emission can be decreased by up to 720 , representing a reduction of about 4% of the total emission at campus Lichtwiese. TU Darmstadt is currently implementing the waste heat integration into its district heating network and will benefit from this concept starting in 2020.

1 October 2021 in Energy Reports
Verified
Journal Article
Open access
FFFrederik Feike
Frederik Feike
JOJohannes Oltmanns
Johannes Oltmanns
FDFrank Dammel
Frank Dammel
PSPeter Stephan
Peter Stephan

1 September 2018 in Energy Procedia
Verified
Journal Article
Open access
JOJohannes Oltmanns
Johannes Oltmanns
MFMartin Freystein
Martin Freystein
FDFrank Dammel
Frank Dammel
PSPeter Stephan
Peter Stephan