3 October 2024 in IEEE Transactions on Instrumentation and Measurement
The continuum manipulators are the most common wrist joint design in surgical robots. However, there is currently no complete and accurate evaluation system to evaluate the performance of the continuum manipulator. In this paper, a static model-based assessment method is proposed to evaluate the dexterity of continuum manipulator. Compared to conventional approaches, the methodology presented in this paper demonstrates superior accuracy and scientific rigor, contributing to the establishment of a comprehensive framework for the evaluation of the dexterity of continuum manipulators. Firstly, static models for three commonly encountered continuum manipulators are established. Based on the Bernoulli-Euler beam theory, the static models for the cable-driven continuum manipulator and hybrid continuum manipulator are established taking into account the large deformations of the manipulators. Compared with the traditional constant curvature model, the average error is reduced from 0.67% to 0.33%. The static model for the concentric tube manipulator is established by solving differential equations and based on differential element method. The average error is reduced from 3.09% to 0.90%. Subsequently, the effective workspace of the continuum manipulators is defined based on operational requirements. Based on the established static models and the service sphere theory, a more accurate dexterity assessment method is proposed within the effective workspace. Finally, the assessment of the dexterity is conducted for the three types of continuum manipulators. Simulation results indicate that within the effective workspace, the average dexterity is 0.4571 for the cable-driven continuum manipulator, 0.2495 for the hybrid continuum manipulator, and 0.1753 for the concentric tube manipulator. This paper is of paramount significance in refining the comprehensive performance evaluation framework for surgical robots.
1 October 2026 in IEEE/ASME Transactions on Mechatronics
Hybrid continuum robots with concentric tubes and cable-driven mechanisms offer compactness and dexterity. However, they face limited adaptability and modeling challenges. This article proposes, for the first time, a multimode operation strategy for the composite continuum robot, enabling switching among high stiffness, high flexibility, and high precision modes. By adjusting the relative position between the concentric tube and the notched continuum, the robot achieves flexible transitions among these modes. A static model based on Euler–Bernoulli beam theory is established, where the bending moments from the concentric tube acting on the notched continuum segment are analytically integrated to reflect coupling effects. Algorithms are designed to achieve the mapping between the driving force and the shape, as well as the mapping relationship between the driving cable length and the robot shape. Based on the Kepler oval and the established static model, the inverse kinematics model of the robot is constructed. Simulations and experimental results show a modeling error of only 0.042 mm (0.084%), outperforming conventional models. The robot demonstrates convenient mode switching, showing performance characteristics, such as high stiffness, high flexibility, and high precision. This work contributes to improved modeling and control strategies for continuum robots.
19 August 2026 in Nonlinear Dynamics
6 October 2026 in Mechanism and Machine Theory