V. M. Tikchonenko

V. M. Tikchonenko

Auto-generated profile, based on publicly available information

V. M. Tikchonenko

LLC «Incart

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2020 in Kardiologiia
Verified
Journal Article
Closed access
PDF file
SBS. O. Bormina
S. O. Bormina
LKLyudmila Korostovtseva
Lyudmila Korostovtseva
MBMikhail Bochkarev
Mikhail Bochkarev
YSYu. V. Sviryaev
Yu. V. Sviryaev
AKA. O. Konradi
A. O. Konradi
VTV. M. Tikhonenko
V. M. Tikhonenko
Objective Carry out a comparative assessment of respiratory performance, based on multifunctional monitoring (MFM) and the recommended practice for complete polysomnography (PSG), and evaluate the effect of the blood pressure (BP) measurements in MFM on the quality of sleep. Materials and Methods At the first stage, 22 healthy volunteers (control group) underwent concomitant PSG and MFM, and 14 patients with suspected sleep-disordered breathing (SDB) underwent only PSG. At the second stage, concomitant PSG and MFM were performed in patients with confirmed SDB. Results In the control group, MFM detected a lower level of SpO2, a lower desaturation index (DI), and a higher apnea index (AI) than in the PSG group. However, the apnea-hypopnea index (AHI) was comparable in both groups. During concomitant PSG-MFM, the measurements of BP increased the number of micro-arousals only in the SDB group. Conclusion Results of the assessment of respiratory performance in MFM are comparable in both groups. The detected features of MFM indicators in the evaluation of the chest movements using rheopneumography, criteria different from that generally used for desaturation and hypoxemia, can lead to underestimation of desaturation and DI and underestimation of AI in the control group. The measurements of BP during sleep induced micro-arousals in the SDB group.

11 January 2023 in Medical alphabet
Verified
Journal Article
Open access
PDF file
VTV. M. Tihonenko
V. M. Tihonenko
VPV. V. Pivovarov
V. V. Pivovarov
ARA. V. Rubinskiy
A. V. Rubinskiy
GZG. K. Zaitsev
G. K. Zaitsev
AKA. Y. Kormilitsyn
A. Y. Kormilitsyn
АКА. Ю. Кормилицын
А. Ю. Кормилицын
   Objective. The article discusses the advantages of performing stress tests with pressure control at each heartbeat. The question of increasing accuracy, informativeness and safety of the test is considered.   Materials and methods. We performed 30 bicycle ergometric tests with ECG measurement, beat to beat blood pressure measurement and periodic blood pressure measurement by the Korotkoff method in the shoulder.   Results. It was shown that arterial pressure registered by Korotkoff sounds in the shoulder corresponded with continuous pressure at the registration moment. Because of the impossibility to measure the dynamics, the underestimation of maximum systolic arterial pressure by the Korotkoff method exceeds 20 mm Hg in every 3 tests, and exceeds 30 mm Hg in every 5 tests. Therefore, the beat to beat measurement of BP significantly improves the accuracy and informativeness value of stress tests.   Conclusions. Continuous BP signal in the finger increases reliability of noisy Korotkoff sounds extraction and the results of BP measurement in the shoulder by the classical method. The increased accuracy and reliability of the measurement provides greater patient safety. Continuous pressure corrected by Korotkoff sounds during reference measurements in the shoulder gives a detailed and accurate picture of BP variations, which allows to investigate in detail features of the patient’s cardiovascular system regulation, both during and after the load, which is not available with classical BP measurement.

27 June 2026 in Systemic Hypertension
Verified
Journal Article
Closed access
ARA. N. Rogoza
A. N. Rogoza
VTV. M. Tikchonenko
V. M. Tikchonenko
YSYu. V. Shubik
Yu. V. Shubik
NFN. L. Frolova
N. L. Frolova
AKA. B. Korneev
A. B. Korneev
GZG. K. Zaitsev
G. K. Zaitsev
Relevance . Arterial hypertension (AH) is a common and independent risk factor for atrial fibrillation (AF). It contributes to AF onset and maintenance, while AF itself increases cardiovascular risk and represents the most common arrhythmia [3]. Hypertension and AF often coexist, and their incidence rising with age [1,3]. Current guidelines define blood pressure (BP) thresholds for diagnosing and when assessing the effectiveness of hypertension treatment in AF [1,3]. However, accurate BP measurement in this group of patients is challenging due to rhythm variability, which disrupts ventricular filling, stroke volume [3,4] and, consequently, pulse pressure. As a result, most used automatic BP monitors are not recommended for this patients [11,12]. However, additional errors and inaccuracies that are possible even when blood pressure is measured by a medical professional remain largely unstudied, highlighting the relevance of this research. Objective. To assess the frequency and magnitude of BP overestimation and underestimation in AF patients using both Korotkov auscultatory and oscillometric methods, and to propose solutions. Materials and Methods . This retrospective study analyzed digital signal archives from microphones and pressure sensors in arm and finger cuffs during synchronous BP measurements (auscultatory, oscillometric, and noninvasive continuous beat-by-beat) in 100 patients with permanent non-valvular AF and 92 patients with regular sinus rhythm. The analyzed digital archive consisted of data from patients with permanent non-valvular AF undergone routine examination and treatment at the North-West Center for Arrhythmia Diagnostics and Treatment (St. Petersburg), as well as patients who had participated in prospective studies at the National Medical Research Center of Cardiology of the Russian Ministry of Health (from 2020 to 2025). Each of the latter studies was approved by the Independent Ethics Committee of the E.I. Chazov National Medical Research Center of Cardiology of the Russian Ministry of Health, and all participants signed an informed consent form. For each patient, a «correct mean» BP value was calculated as follows. To compensate for large variations in individual BP values, as well as known physiological BP variability, the average value was calculated from ≥1000 «beat-by-beat BP values» obtained noninvasively over the entire measurement period (15 minutes). The average value of five BP readings was determined at the same time using the Korotkov or oscillometric methods. Differences between the «correct average» BP values and the average Korotkov and oscillometric methods values were analyzed statistically in MATLAB. Results . It was shown that, in a regular sinus rhythm, Korotkov BP measurements had a high correlation and did not differ from correctly averaged «beat-bybeat» BP readings over several minutes, with no significant differences > 10 mmHg. However, in patients with AF, Korotkov systolic BP was overestimated by an average of 6.4±6.2 mmHg, and in 25% of patients overestimation can increases up to 25-30 mmHg. Korotkov diastolic BP was underestimated by −3.0±4.4 mmHg (p 10 mmHg. These discrepancies occurred mainly in patients with a pulse deficit >16% (low-amplitude BP pulsations). The oscillometric method did not reduce these discrepancies, indicating the need for noninvasive continuous beat-by-beat BP monitoring.

29 December 2024 in Journal of Arrhythmology
Verified
Journal Article
Open access
PDF file
YSYu. V. Shubik
Yu. V. Shubik
AKA. B. Korneev
A. B. Korneev
MBMaria A. Baturova
Maria A. Baturova
AMA. N. Morozov
A. N. Morozov
VPV. V. Pivovarov
V. V. Pivovarov
АКА. Ю. Кормилицын
А. Ю. Кормилицын
The aim is to assess the relationship between systolic, diastolic, and pulse blood pressure (SBP, DBP, PBP) during ventricular extrasystoles (VE) and the individual characteristics of ectopic beats.Methods. The primary method of investigation was BP measurement for each heartbeat. Inclusion criteria were the presence of ≥10000 monomorphic VE per day. A total of 53 patients were included, either without structural heart changes or with minimal structural alterations. The mean of systolic, diastolic, and pulse BP (SBP, DBP, and PBP) during VE (SBP VE, DBP VE, PBP VE) and during post-extrasystolic sinus contraction (post VE SBP, post VE DBP, post VE PBP) were calculated for each patient as fractions of 1.0.Results. The QRS complex width in VE originating from the right ventricular outflow tract is greater than from the left ventricular outflow tract; fragmentation of the QRS complex is more commonly observed in these VE. Significant correlations were observed between SBP VE and mean coupling interval (CI), PBP VE and CI, and SBP VE and PBP VE, though not between DBP VE and CI. DBP VE was significantly associated with VE count and daily VE percentage, while PBP VE was associated with left ventricular ejection fraction. It has been shown that post-VE SBP and post VE DBP are lower, while post VE PBP is higher compared to the corresponding parameters of sinus beats preceding the VE. Significant relationships were found between post VE SBP and post VE PBP, the duration of the post-extrasystolic pause, and the presence of paired VE; between post VE DBP and post VE PBP, DBP VE, CI VE, the presence of non-sustained ventricular tachycardia, and daily VE percentage; between post VE PBP and DBP VE, the presence of non-sustained ventricular tachycardia, daily VE percentage, and post-extrasystolic pause duration. Post VE PBP was equally determined by values of post VE SBP and DBP.Conclusion. With the shortening of the VE coupling interval, its SBP decreases, while DBP increases slightly, which may determine its hemodynamic significance. In post-extrasystolic sinus beats, both SBP and DBP decrease.