Bin Wang

Bin Wang

Auto-generated profile, based on publicly available information

Bin Wang

Department of Automation, Tsinghua University, Beijing, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2024 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
ZLZhiyu Lu
Zhiyu Lu
LYLi Yang
Li Yang
BWBin Wang
Bin Wang
KWKun Wu
Kun Wu
YLYongxin Li
Yongxin Li
XZXiaoping Zheng
Xiaoping Zheng
Magnetic sensor arrays are typically used to detect magnetic targets. Currently, research on sensor array calibration focuses on solving the problems of inconsistent sensitivity, zero offset, and non-orthogonality in individual sensors, and misalignment errors between sensors. However, in magnetic field detection, sensor arrays are usually mounted on a platform or carried as a handheld device and are prone to random swaying during the detection process, leading to changes in the attitude and position of the magnetic sensors, which in turn generates swaying errors. In this study, the source of swaying error in sensor arrays was first analyzed theoretically, and a swaying error model of a magnetic sensor was established. Second, an swaying error calibration method was proposed in combination with the classical prediction model— Gaussian Process Regression (GPR), Backpropagation Neural Network (BP) and Support Vector Machine (SVM) in the field of artificial intelligence. The experimental results show that the prediction performance based on the BP neural network is the most outstanding. After correction, the relative error percentage of the swaying error in the magnetic field data decreased significantly from 165.50% to 9.35%, which is a significant improvement of the correction effect. In addition, we conducted model comparison experiments in different environments, and the results show that the BP model performs well in various environments, demonstrating its strong generalization ability and robustness. Finally, the distance error of the magnetic dipole position was significantly reduced after calibration, from 1.56 m, 1.12 m, and 2.50 m to 0.17 m, 0.04 m, and 0.04 m, respectively. Thus, the effectiveness of the calibration method was verified.

4 March 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LYLi Yang
Li Yang
ZLZhiyu Lu
Zhiyu Lu
BWBin Wang
Bin Wang
KWKun Wu
Kun Wu
XZXiaoping Zheng
Xiaoping Zheng
The difficulty in magnetic multi-target recognition is that it is difficult to recognize magnetic targets with different magnetic moments and different depths at the same time. This is because the magnetic moment and depth of a magnetic target affect the strength of the generated magnetic field information, resulting in localization results that favor targets that generate stronger magnetic fields, while targets with weaker magnetic fields cannot be accurately identified. In addition, the traditional Euler equation-based multi-target localization method requires calibration of the sensor array before detection, which requires high calibration accuracy as it relies on the inversion of mathematical equations to solve for magnetic targets. To address this problem, this paper proposes an inverse tangent function imaging processing method based on the magnetic gradient tensor information (MGT) depth direction change rate. The method aims to balance the differences in magnetic field information between different magnetic targets and enhance the recognition of the horizontal position of targets with weaker magnetic fields. Based on this, a depth detection method based on MGT is proposed to acquire the depth information of magnetic targets. A grid-format data acquisition method is also proposed to obtain the MGT. The method does not require calibration of the sensor array or separation of the magnetic anomaly field from the total field. Simulation and experimental results show that the positioning error of this method for each magnetic target in the x, y, and z axes is less than 0.15 m. For a magnetic target with a depth of 1 m, the x-axis error is 0.15 m, the y-axis error is 0.05 m, and the z-axis error is 0.06 m. For a magnetic target with a depth of 0.7 m, the x-axis error is 0.08 m, the y-axis error is 0.12 m, and the z-axis error is 0.13 m.

13 December 2021
Verified
Conference Paper
Closed access
PDF file
XMXinxue Ma
Xinxue Ma
JWJianli Wang
Jianli Wang
BWBin Wang
Bin Wang
XLXinyue Liu
Xinyue Liu
HLHongwen Li
Hongwen Li
With the rapid development of national defense, aerospace and other fields, the demand for high precision and high quality photoelectric products is increasing day by day, and these photoelectric products are gradually developing toward miniaturization. If the optical elements use a free-form, the imaging quality of the optical imaging system can be greatly improved, and the illumination uniformity of the optical illumination system and the transmission efficiency of the information transmission system can also be remarkably improved. With free-form optics becoming the leading representative technology of advanced optical engineering, optical metrology technologies for free-form optics has become the hotspot research of current science-technology development. In this paper, the development of optical metrology technologies, the present situation and the advantages and disadvantages of various metrology technologies are described in detail, which will be of guiding significance for future research on optical metrology technologies for free-form optics.