Yan Lu

Yan Lu

Auto-generated profile, based on publicly available information

Yan Lu

University of Science and Technology Beijing

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2022
Verified
Conference Paper
Closed access
GCGuigang Cai
Guigang Cai
YLYan Lu
Yan Lu
RMRui Martins
Rui Martins
The profile of portable and wearable devices keeps shrinking, demanding high current density power management integrated circuits. Switched-capacitor (SC) converters and buck converters are two common solutions. Unregulated SC converters can achieve high power density and high efficiency for specific voltage conversion ratios (VCRs). However, to cover wide input and output voltage ranges, they require a reconfigurable topology with multiple VCRs, thus increasing the system complexity. On the other hand, buck converters can reach a good efficiency over a wide continuous VCR range. Yet, they need a bulky inductor, which significantly degrades the power density. To address the power density and efficiency tradeoff, hybrid converters composed of both inductor and capacitor are among popular solutions [1 – 4]. When compared with the traditional buck converter, these hybrid converters feature lower voltage swing (smaller current ripple) of the inductor, higher switching frequency, and a larger duty cycle (D) for the same VCR, alleviating the requirements on the inductor, and resulting in higher power density. Nevertheless, as all the output current I OUT goes through the inductor, this implies a large volume for small DCR and conduction loss ${P_{\text{COND}}}$ _ L . Recently, hybrid converters with reduced inductor current I L have emerged [5 – 7]. In these hybrid converters, the SC not only lowers down the voltage of the switch node, but also offers another current path to the output, reducing the inductor current. In this work, we propose an SC-parallel-inductor buck topology (which we refer to as CPL-Buck since in the proposd structure there is a capacitor that is always in parallel with the inductor) that can further reduce / L to less than 0.5I OUT , meaning a P COND _ L reduction of over 75% for the same DCR. Measurement results show that, for 1.2A maximum I OUT , 3-to-4.2V input to 0.6-to-1V output, the proposed CPL-Buck obtains a peak efficiency of 92.9% and a peak current density of 0.3A/mm 2 with a power inductor as small as 1.6×0.8×0.8mm 3 .

2 November 2023 in Measurement Science and Technology
Verified
Journal Article
Closed access
YLYan Lu
Yan Lu
ZHZhihui Hong
Zhihui Hong
SQShengjie Qiu
Shengjie Qiu
LZLu Zhang
Lu Zhang
JSJinji Sun
Jinji Sun
The permeability of permalloy at ultra-low-frequency magnetic field is a crucial and fundamental parameter for analyzing the low frequency shielding factor of magnetically shielded rooms. However, due to limitations in the accuracy of the existing magnetic flux signal measuring system, the permeability at ultra-low-frequency magnetic field is challenging to precisely determine. Therefore, a high-precision voltammetry method for measuring the permeability of permalloy at ultra-low-frequency magnetic field is proposed in this paper. First, the theory of the voltammetry method and the required level of induced voltage accuracy are derived and thoroughly analyzed. Then, the voltage acquisition module with ultra-low noise is designed by using four parallel instrumentation amplifiers, and the magnitude of the noise is quantified by establishing the noise analysis model for the voltage acquisition module. Finally, the system for measuring the permeability at ultra-low-frequency magnetic field is set up, and its feasibility is verified by comparing the measurement results of permeability at 10 Hz with the commercial soft magnetic instrument. The results show that the system is capable of measuring the permeability of permalloy at 0.01 Hz to 1 Hz, with repeatability error of less than 3%. The method can also be applied to measure the permeability of other soft magnetic materials.

25 January 2024 in Physica Scripta
Verified
Journal Article
Closed access
JSJinji Sun
Jinji Sun
XZXiuqi Zhao
Xiuqi Zhao
XZXu Zhang
Xu Zhang
DZDi Zhang
Di Zhang
ZZZhenkai Zhao
Zhenkai Zhao
YLYan Lu
Yan Lu
Magnetic shielded cylinder (MSC) is crucial in various applications, especially in the realm of medical weak magnetic signal measurement. However, designing a small volume, low noise MSC is a multi-objective optimization problem, with the objectives conflict with each other. To address the complexity arising from numerous variables in the optimal design of MSC with a small volume and low-noise, this paper proposes an optimal design method based on non-dominated sorting genetic algorithm II (NSGA-II) to realize the optimal design of MSC with a high shielding factor, small volume and low-noise. Firstly, an analytical model for the shielding factor of the MSC is established, and a multi-objective optimization model is given. Then, the NSGA-II algorithm is employed to obtain a series of Pareto frontier optimal solutions. Finally, the efficacy of this method is evaluated through simulation and experimentation. The results reveal that the radial and axial shielding factors of the optimized MSC achieve maximum values of 8.6 × 107 and 9.5 × 106 respectively. Meanwhile, the average axial noise and radial noise of the MSC between 1 and 100 Hz are 22 fT/Hz1/2 and 20 fT/Hz1/2 respectively. Practice has proven that this method can be used to optimize the design of small-volume, low-noise magnetic shields to improve the performance of magnetic shields.

2 July 2024 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
YLYan Lu
Yan Lu
SQShengjie Qiu
Shengjie Qiu
JSJinji Sun
Jinji Sun
LZLu Zhang
Lu Zhang
JTJiqiang Tang
Jiqiang Tang
Rectangular magnetically shielded rooms (MSRs) are favored for their construction simplicity and efficient space usage. However, current rectangular MSRs lack an effective shielding factor (SF) theoretical system due to their inherent asymmetric geometry and process defects such as door gap. Therefore, an effective three-dimensional (3D) magnetic circuit method for calculating the SF of rectangular MSRs is proposed in this paper. Firstly, the theoretical model for the 3D magnetic circuit of rectangular MSRs is established, and the SF in three directions is derived. Secondly, the theoretical model is modified by introducing demagnetization factors to further improve the calculation accuracy of the SF based on the magnetization theory. Finally, formula systems for the SF considering door gap are derived, and their effect is also analyzed. To validate the proposed method, two rectangular MSRs with distinct structures are tested using a constructed experimental platform. The results show that the discrepancy between the calculated SF and the tested SF is less than 7%, affirming the efficacy of the proposed methodology. This method can be applied to rectangular MSRs of different sizes, and provide a valuable theoretical guidance for the construction of MSRs.

28 June 2024 in Physica Scripta
Verified
Journal Article
Closed access
XZXiuqi Zhao
Xiuqi Zhao
YLYan Liu
Yan Liu
LZLu Zhang
Lu Zhang
XLXianhong Li
Xianhong Li
Xu ZhangXu Zhang
Xu Zhang
JSJinji Sun
Jinji Sun
Investigating the state of cells in zero magnetic or near-zero magnetic environments is an important scientific issue. However, standard cell culture incubators can only provide general conditions such as constant temperature, constant humidity, sterility, and carbon dioxide, and cannot provide zero magnetic or near-zero magnetic environments for cell culture. To address this issue, an optimization method was proposed in this paper based on the combination of the particle swarm optimization algorithm (PSO) and the finite element method (FEM), achieving the optimization design of a magnetic shielding box (MSB) with a small volume, high shielding factor, and low residual field. Firstly, the high-permeability layer and high-conductivity layer were optimized respectively using the PSO and FEM. Then, the effectiveness of this method was analyzed through experiments. The experimental results show that the shielding factors in three directions at the center point of the optimized MSB are 786.8 (east-west), 2182.7 (north-south), and 1389.4 (vertical) respectively at 0.01 Hz. Meanwhile, the maximum residual field in the cubic region with a side length of 10 cm inside the MSB is 11.9 nT. Finally, the MSB designed by this method was placed in a standard cell culture incubator to cultivate cells in a zero-magnetic or near-zero magnetic environment. Then the Cell Counting Kit-8 (CCK8) experiments to evaluate the cytotoxicity of chemotherapy drugs on tumor cells in a weak magnetic environment (WMF). The results show that the lethality of paclitaxel (PTX) to Epidermal carcinoma cell (A431) increases by 25.96 times and the lethality of gemcitabine (GE) to Lung carcinoma cell (NCI-H460) increases by 24.23 times in a WMF. At the same time, the maximum proliferation inhibition rate of 5-fluorouracil (5-FU) on NCI-H460 cells in a WMF environment increased by 15.69%. That is, WMF could significantly improve the therapeutic effect of chemotherapy drugs on tumor cells.

1 January 2026 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
YLYan Lu
Yan Lu
JLJiangyun Lee
Jiangyun Lee
TZTianxiang Zhang
Tianxiang Zhang