16 October 2017 in IEEE Transactions on Magnetics
Electromagnetic (EM) field simulation plays a key role in the design of magnetic resonance imaging radio frequency (RF) coils. However, the values of the components in tuning and matching circuits often need to be iterated repeatedly in the conventional simulation method in order to achieve optimal scattering parameters. This leads to a time-consuming optimization to tune and match RF coils, particularly dual-tuned coils that are comprised of multiple lumped elements. A method combining EM field simulation and circuit simulation was employed in this paper, which can dramatically improve simulation efficiency for the optimization of the values of the lumped elements and corresponding EM field distribution. A systematical theoretical analysis of the co-simulation method was presented. To validate the accuracy and efficiency of the co-simulation method, a comparison study was conducted between the conventional simulation and the proposed co-simulation approaches.
13 August 2018 in IEEE Transactions on Magnetics
Radio frequency (RF) coils are an important component of magnetic resonance imaging (MRI) equipment. However, the field of ultrahigh-field RF coil research is fraught with technical challenges which limit the development of magnetic resonance technology. Thus, the research on the performance of ultrahigh magnetic field RF coils is a primary focus on the study of the ultrahigh-field MRI system. The development of 1 H/ 31 P dual-nuclear RF coils based on the ultrahigh-field MRI system is greatly significant for the research on the diagnosis and metabolism changes of many disease conditions such as tumors. In this paper, a 1 H/ 31 P dual-nuclear multi-channel RF coil for the ultrahigh magnetic field 7 T MRI was proposed. The performance of the proposed coil was evaluated by using a numerical co-simulation approach, and phantom studies were conducted on the Siemens 7 T MRI system. The results demonstrate the feasibility of the proposed double-nuclear RF coil in the application of 1 H/ 31 P ultrahigh magnetic field MRI.
18 March 2024 in IEEE Access
Accurately determining tumor regions from stereo fluoroscopic images during radiotherapy is a challenging task. As a result, high-density fiducial markers are implanted around tumors in clinical practice as internal surrogates of the tumor, which leads to associated surgical risks. This study was conducted to achieve lung tumor localization without the use of fiducial markers. We propose training a cascade U-net system to perform color to grayscale conversion, enhancement, bone suppression, and tumor detection to determine the precise tumor region. We generated Digitally Reconstructed Radiographs (DRRs) and tumor labels from 4D planning CT images as training data. An improved maximum projection algorithm and a novel color-to-gray conversion algorithm were proposed to improve the quality of the generated training data. Training a bone suppression model using bone-enhanced and bone-suppressed DRRs enables the bone suppression model to achieve better bone suppression performance. The mean peak signal-to-noise ratios in the test sets of the trained translation and bone suppression models are 39.284 ± 0.034 dB and 37.713 ± 0.724 dB, respectively. The results indicate that our proposed markerless tumor localization method is applicable in seven out of ten cases; in applicable cases, the centroid position error of the tumor detection model is less than 1.13 mm; and the calculated tumor center motion trajectories using the proposed network highly coincide with the motion trajectories of implanted fiducial markers in over 60% of captured groups, providing a promising direction for markerless tumor localization tracking methods.
10 February 2025 in IEEE Transactions on Radiation and Plasma Medical Sciences
The total-body PET scanning time is typically reduced to mitigate motion artifacts, yet this can compromise image quality. Current approaches often enhance PET resolution via CT guidance but overlook structural disparities across anatomical sites. Therefore, this paper introduces an enhanced Wasserstein generative adversarial network with gradient penalty (WGAN-GP), integrating anatomical information as attributes to enhance quality of multiple short-duration (2.5%, 5%, 10%) total-body PET images simultaneously. The proposed method is a weight-adaptive three-channel network for different regions, integrating PET/CT features and attributes to optimize short-duration PET image generation. Peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), root mean square error (RMSE) and standard uptake value (SUV) are analyzed within whole images and regions of interest (ROIs) to compare proposed method with other networks. The results on the 18F-FDG PET dataset show the method achieves better visual effects and metrics (like SSIM: 0.94± 0.04 for 2.5%; 0.95± 0.04 for 5%; 0.96± 0.04 for 10%) across total-body than others. Furthermore, the SUV-maximum and activity distributions of ROIs are closest to standard-duration PET. Additionally, the method demonstrates robustness under varying degrees of 18F-FDG PET/CT misalignment and in the PSMA PET/CT dataset. The proposed method offers reliable technical support for clinical diagnosis via short-duration total-body PET.