We demonstrate the single photon counting mode at 405 and 850 nm with stoichiometric TiN-based microwave kinetic inductance detectors realized on a sapphire substrate and operated at bath temperatures over 300 mK. The detectors use single 15–25 nm-thick TiN layers featuring a critical temperature in the 2–3 K range. We found that the energy-resolving power R=E/ΔE exhibits an optimum with bath temperature, occurring in the 300–450 mK range, which can be almost double compared to those obtained at the lowest temperatures. Furthermore, the single photon regime is observed up to 700 mK. In addition to a high-temperature operation, the single stoichiometric layer would allow achieving a better uniformity in the critical temperature and, thus, kinetic inductance, compared to the often desired ∼1 K sub-stoichiometric TiN.
In this paper, we investigate the single photon response from the reflection of the microwave kinetic inductance detector (MKID) array. Reflection measurements are carried out using two configurations: one is measured simultaneously with the transmission, and the other is obtained with a single-ended MKID array terminated with an open load. Compared with the transmission, reflection measurements significantly reduce the readout noise of the single-ended MKID array. This is also reflected in the improvement of the median energy resolving power by around 20%–30% under pulsed photon illumination at λ = 405 nm, mainly due to an increase in the size of the resonance circle on the IQ plane. This method has the potential to be used to read out large MKID arrays.