Yilin Zhong

Yilin Zhong

Auto-generated profile, based on publicly available information

Yilin Zhong

State Key Laboratory of HVDC Transmission Technology, China Southern Power Grid Electric Power Research Institute Co., Ltd., Guangzhou 510663, China

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2026 in Electronics
Verified
Journal Article
Open access
PDF file
YSYinsheng Su
Yinsheng Su
FPFaxi Peng
Faxi Peng
GLGuiyuan Li
Guiyuan Li
LHLiu Hongtao
Liu Hongtao
YZYilin Zhong
Yilin Zhong
HXHuifan Xie
Huifan Xie
Modeling and stability analysis of a PV–energy storage AC/DC integrated three-port grid-connected power electronic device is investigated in this paper for low-voltage single-phase renewable energy applications. The device consists of a PV Boost converter port, a battery-side bidirectional DC-DC converter port, and a single-phase full-bridge grid-connected inverter. To analyze the coupling-induced stability characteristics of this multi-converter system, mathematical models of the PV array, battery, and AC/DC integrated device are established. Considering the periodic time-varying nature introduced by the single-phase grid voltage, a phase-angle-based simplified discrete model is developed to transform the system into a discrete model evaluated at a fixed grid-voltage phase angle. Based on this model, eigenvalue sensitivity, eigenvalue trajectories, and bifurcation diagrams are used to identify the influence of key control parameters on system stability. The results show that excessive proportional gains in the inverter current loop and energy storage control loop reduce the stability margin and may lead to period-doubling bifurcation, Hopf bifurcation, or unstable grid current operation. The period-doubling and Hopf stability boundaries are identified at kp4 ≈ 1.40 and kp2 ≈ 1.75, respectively. In simulation, the grid-current THD increases from 2.07% to 3.60% as kp4 rises from 1.3 to 1.6 and from 2.07% to 2.27% as kp2 rises from 1.7 to 1.8. MATLAB/Simulink simulations and hardware-in-the-loop experiments further verify that the identified stability boundaries are consistent with the degradation of grid current quality and the increase in total harmonic distortion. The proposed modeling and analysis method provides a reference for parameter tuning and stable operation of single-phase PV–energy storage three-port grid-connected devices.

1 August 2026 in Electronics
Verified
Journal Article
Open access
PDF file
GLGuiyuan Li
Guiyuan Li
FPFaxi Peng
Faxi Peng
YSYinsheng Su
Yinsheng Su
YZYilin Zhong
Yilin Zhong
YYYi Yuan
Yi Yuan
HXHuifan Xie
Huifan Xie
With the widespread adoption of voltage-source converters for grid-connected new energy power generation, the transient stability of VSCs under high penetration of new energy has become a key issue in the construction of modern power systems. Grid-following (GFL) and grid-forming (GFM) controls each have their applicable scenarios and inherent limitations. Traditional hybrid synchronous control uses fixed parameters, making it difficult to adapt to complex and variable grid conditions. Therefore, this paper proposes a control method suitable for an adaptive hybrid synchronous architecture with grid-following and grid-forming dual characteristics, employing a model predictive control strategy to achieve dynamic adjustment of GFL and GFM control ratios in both the synchronization loop and the voltage loop. A simulation model was built in PSCAD/EMTDC to verify the effectiveness and adaptability of the proposed control method under various transient conditions, such as load changes and voltage sags. The simulation results indicate that the method can effectively suppress system frequency and voltage fluctuations, enhance the transient stability of VSCs, and provide a feasible control reference for practical engineering applications.

25 July 2026 in Electronics
Verified
Journal Article
Open access
PDF file
JWJiaqi Wu
Jiaqi Wu
ZGZhu Guo
Zhu Guo
BZBo Zhu
Bo Zhu
HCHaoli Chen
Haoli Chen
HLHao Lu
Hao Lu
YLYuansheng Liang
Yuansheng Liang
Embedded Modular Multilevel Converter-Based Multi-Terminal Direct Current (MMC-MTDC) systems have become an important solution for enhancing transmission capacity and operational flexibility in urban hybrid AC/DC power grids. However, the coexistence of Grid-Following (GFL) and Grid-Forming (GFM) MMC stations introduces complex dynamic interactions through both AC and DC networks. Existing small-signal stability studies often neglect MMC internal dynamics, such as submodule capacitor voltage fluctuations and circulating current-related states, or simplify the AC network as an ideal voltage source, which may lead to inaccurate stability assessment and limited control parameter optimization performance. To address these issues, this paper proposes a coordinated small-signal stability enhancement strategy for an embedded heterogeneous MMC-MTDC system considering AC/DC bilateral coupling. First, a system-level full-order small-signal state-space model is established by incorporating the internal dynamics of both GFL-MMC and GFM-MMC stations, non-ideal AC networks, and DC transmission links. Then, eigenvalue analysis and participation factor-based sensitivity evaluation are performed to identify weakly damped oscillation modes and screen the key variables and control parameters associated with dominant oscillations. Furthermore, a quadratic performance index is constructed by weighting the sensitivities of key control parameters, and particle swarm optimization is employed to obtain coordinated optimized parameters for heterogeneous MMC stations. Comparative case studies and PSCAD/EMTDC time-domain simulations verify the effectiveness of the proposed strategy under different scenarios. The quantitative active-power indices show that, compared with the unoptimized parameters, Strategy 2 reduces the settling time by 49.1% in the power step response, suppresses the power step overshoot from 6.4% to 0%, shortens the settling time by 53.8% under grid-strength variation, and reduces the active-power peak and settling time by 28.0% and 74.8%, respectively, under the fault ride-through scenario.

17 October 2025 in Energies
Verified
Journal Article
Open access
PDF file
BXBinbin Xu
Binbin Xu
MLMengqi Liu
Mengqi Liu
YZYilin Zhong
Yilin Zhong
PCPeijie Cong
Peijie Cong
BZBo Zhu
Bo Zhu
ZDZhengchun Du
Zhengchun Du
With access to new energy sources, the problem of reactive power optimization and dispatching has become increasingly important for research. However, the reactive power optimization problem is a mixed integer nonlinear optimization problem. In order to solve the integer variables and nonlinear conditions existing therein, a method for coordinated reactive power optimization and dispatching based on semidefinite programming is proposed. Firstly, a reactive power optimization model considering discrete variables and continuous variables is established with the minimization of total operating cost as the objective function; secondly, the discrete variables are transformed into equality constraints by quadratic equations, and then a solvable semi-definite programming problem is obtained; thirdly, the rank-one constraint is restored by the Iterative Optimization based Gaussian Randomization Method (IOGRM), and the optimal solution equivalent to the original problem is obtained. Finally, the correctness and effectiveness of the proposed model and solution method are verified by analyzing and comparing with the second-order cone programming (SOCP) through the modified IEEE standard example.