In this paper, an improved ant lion optimization (IALO) algorithm for parameter identification of hydraulic turbine governing system (HTGS) is proposed. In the proposed algorithm, the search space is explored by the ant lion optimization first, and then the domain is searched by the particle swarm optimization (PSO) in each iteration cycle. A chaotic mutation operation namely Logistics map is introduced for the elite to break out of the local optimum. In mutation operation, a serial-parallel combined method is developed to increase the diversity of mutant population. When the proposed IALO algorithm is applied in the parameter identification of HTGS, the comparative simulation results show that the proposed IALO algorithm has the highest accuracy among different optimization algorithms, and the proposed IALO algorithm has a good convergence characteristic and high stability.
Modeling and stability analysis of a PV–energy storage AC/DC integrated three-port grid-connected power electronic device is investigated in this paper for low-voltage single-phase renewable energy applications. The device consists of a PV Boost converter port, a battery-side bidirectional DC-DC converter port, and a single-phase full-bridge grid-connected inverter. To analyze the coupling-induced stability characteristics of this multi-converter system, mathematical models of the PV array, battery, and AC/DC integrated device are established. Considering the periodic time-varying nature introduced by the single-phase grid voltage, a phase-angle-based simplified discrete model is developed to transform the system into a discrete model evaluated at a fixed grid-voltage phase angle. Based on this model, eigenvalue sensitivity, eigenvalue trajectories, and bifurcation diagrams are used to identify the influence of key control parameters on system stability. The results show that excessive proportional gains in the inverter current loop and energy storage control loop reduce the stability margin and may lead to period-doubling bifurcation, Hopf bifurcation, or unstable grid current operation. The period-doubling and Hopf stability boundaries are identified at kp4 ≈ 1.40 and kp2 ≈ 1.75, respectively. In simulation, the grid-current THD increases from 2.07% to 3.60% as kp4 rises from 1.3 to 1.6 and from 2.07% to 2.27% as kp2 rises from 1.7 to 1.8. MATLAB/Simulink simulations and hardware-in-the-loop experiments further verify that the identified stability boundaries are consistent with the degradation of grid current quality and the increase in total harmonic distortion. The proposed modeling and analysis method provides a reference for parameter tuning and stable operation of single-phase PV–energy storage three-port grid-connected devices.
With the widespread adoption of voltage-source converters for grid-connected new energy power generation, the transient stability of VSCs under high penetration of new energy has become a key issue in the construction of modern power systems. Grid-following (GFL) and grid-forming (GFM) controls each have their applicable scenarios and inherent limitations. Traditional hybrid synchronous control uses fixed parameters, making it difficult to adapt to complex and variable grid conditions. Therefore, this paper proposes a control method suitable for an adaptive hybrid synchronous architecture with grid-following and grid-forming dual characteristics, employing a model predictive control strategy to achieve dynamic adjustment of GFL and GFM control ratios in both the synchronization loop and the voltage loop. A simulation model was built in PSCAD/EMTDC to verify the effectiveness and adaptability of the proposed control method under various transient conditions, such as load changes and voltage sags. The simulation results indicate that the method can effectively suppress system frequency and voltage fluctuations, enhance the transient stability of VSCs, and provide a feasible control reference for practical engineering applications.