29 June 2026 in Eastern-European Journal of Enterprise Technologies
This work considers the process of dust pollution of the air at an industrial site when using a protective perforated screen. The removal of dust from contaminated land surfaces in areas where there are coal storage facilities leads to intensive air pollution in working areas. This poses a threat to the health of workers. Therefore, for practice, an important solution is to reduce the level of dust pollution of the air at industrial sites. A likely engineering solution to such a task is to use protective screens, in particular, protective screens with perforations. These screens reduce the speed of the oncoming wind flow, which, in turn, reduces the intensity of dust formation. The location of the screens at an industrial site is important. A laboratory experiment was conducted to determine the patterns of air flow velocity distribution behind a protective screen with perforations. The experimental data showed that the screen makes it possible to reduce the wind flow velocity by 5–6 times over an extension of the order of 2H from the screen (H is the height of the screen). The air flow velocity increases intensively behind the screen in the area 2H–4H. These results make it possible to determine the rational location of the screen relative to the dust formation area. For theoretical assessment of the effectiveness of these screens, a numerical model was built based on the fundamental equations of continuum mechanics. The modeling equations include the dust mass transfer equation and the potential motion equation. Using the constructed numerical model, a computational experiment was conducted, which confirmed the effectiveness of using perforated protective screens: the area of dust air pollution in height decreased almost 3 times. The cost of computer time for conducting a computational experiment is 2 seconds. This makes it possible, when carrying out design work, to perform a series of calculations in a short period of time
28 October 2026 in Eastern-European Journal of Enterprise Technologies
This study considers a dust distribution process in a dust-settling chamber, which has a complex geometric shape and additional structural elements in the form of plates. To determine the efficiency of air purification in the chamber after installing the plates, it is necessary to build a mathematical model of the dust deposition process. This work constructs a fast-calculating mathematical model to assess the influence of plates inside the dust-settling chamber on the efficiency of air purification. Specifically, a dust concentration field formation inside the dust-settling chamber under the action of gravity and the phenomenon of diffusion. A feature of the constructed numerical model is the use of the equation of potential air motion, which provides a quick calculation of the gas flow velocity field in the dust-settling chamber that has a complex geometry and the presence of plates. The process of dust distribution in the dust-settling chamber is modeled on the basis of a mass transfer equation, which takes into account the non-uniform gas flow velocity field in the chamber, gravitational deposition of dust particles, and the diffusion process. The results indicate that the arrangement of the plates inside the dust-settling chamber makes it possible to reduce the slip coefficient by 1.4–3.5 times for different chamber configurations. This is explained by the slowdown of the air flow velocity near the plates, which contributes to a more intensive deposition of dust particles under the action of gravity. Due to this process, the amount of dust remaining inside the chamber increases. The results of this study showed that it is possible to improve the efficiency of an existing dust-settling chamber by such simple means. The results could be used to improve the operation of dust-settling chambers in which primary air purification from dust is carried out
21 June 2026 in Ventilation, Illumination and Heat Gas Supply
The article considers the design of the universal solid-fuel heat-generating installation "Khymera" featuring an annular combustion chamber, a "dry" cylindrical gravity shaft furnace with layered fuel combustion on cast-iron grates, and cast-iron cylindrical thermal accumulators. It utilizes a self-regulating sectional supply of primary and secondary air to the combustion zone and a fire-tube three-pass vertical heat exchanger for efficient heat extraction from flue gases. This installation is designed for highly efficient combustion of lumpy biofuel of various origins and reliable heating of premises. The design features of the heat-generating installation, its operating principle, fuel flexibility, and environmental advantages are analyzed. It is shown that the application of multi-zone combustion technology and the afterburning of pyrolysis gases allows achieving high thermal efficiency and reducing the level of harmful emissions. The developed "Khymera" installation combines classic combustion in a gravity furnace with multi-zone combustion technology and pyrolysis gas afterburning. The air supply system is implemented using a three-zone scheme (primary, secondary, and tertiary air), which ensures complete oxidation of volatile components at high temperatures. It has been experimentally proven that the automated supply of lumpy biofuel ensures a stable temperature regime in the combustion chamber within 720–850 °C and smooth regulation of the thermal load without sharp fluctuations. It has been established that high-temperature afterburning significantly reduces the concentration of carbon monoxide (CO) and unburned particles, while the overall efficiency of the installation reaches 85–90%. Automation also made it possible to partially compensate for the negative impact of increased fuel moisture on combustion stability through timely adjustment of air consumption. A gravity furnace with an automated supply of lumpy biofuel is an effective, technologically sound, and environmentally safe solution for heat supply systems. The integration of PLC control in combination with pyrolysis-diffusion combustion schemes significantly increases combustion stability, reduces dependence on the human factor, and minimizes losses from chemical underburning, ensuring the installation complies with modern strict environmental and energy requirements.
30 December 2025 in Eastern-European Journal of Enterprise Technologies
This study investigates the sequential and continuous formation of thermal fields in the main fairing of a launch vehicle when using protective screens. While thermostating, it is necessary to predict the risk in overheating the payload body and, if necessary, take measures to reduce the temperature near the payload. An engineering solution to this problem can be found through the use of protective screens of various configurations inside the main fairing. These screens reduce the heat flow from the heated outer wall of the fairing to the payload surface. However, there are no standard methods for solving this problem. To evaluate the effectiveness of this protection, a numerical model based on the fundamental equations of continuum mechanics has been constructed. The modeling equations include the energy equation and the equation of motion of a non-viscous gas. Using the numerical model built, a computational experiment was conducted, which confirmed the effectiveness of using protective screens to shield the payload body from excessive heating. The computer time required to perform the computational experiment is 3 seconds. This makes it possible to perform a significant number of calculations in a working day. The proposed simple technical means for protecting the payload from excessive heating could be used in the design of new models for rocket technology. Applying these screens slightly reduces the need for large volumes of clean air. The numerical model built could be used at specialized organizations at the “for-sketch” design stage. Numerical experiments have shown that the use of protective screens inside the main fairing makes it possible to achieve a temperature 2–4°C lower than the maximum permissible temperature near the payload