7 August 2024 in Microsystems & Nanoengineering
To address the serious acoustic performance deterioration induced by air leakage in the low-frequency range and the asynchronous vibration in electroacoustic transduction structures near the resonant frequency, a novel sealing strategy is proposed that targets one of the most widely reported piezoelectric MEMS speaker designs. This design consists of multiple cantilever beams, in which the air gaps between cantilevers are automatically and selectively filled with liquid polydimethylsiloxane (PDMS) via the capillary effect, followed by curing. In the proof-of-concept demonstration, the sound pressure level (SPL) within the frequency range lower than 100 Hz markedly increased after sealing in an experiment using an IEC ear simulator. Specifically, the SPL is increased by 4.9 dB at 20 Hz for a 40 Vpp driving voltage. Moreover, the deteriorated SPL response near the resonant frequencies of the cantilever beams (18 kHz–19 kHz) caused by their asynchronous vibration induced by the fabrication process nonuniformity also significantly improved, which successfully increased the SPL to approximately 17.5 dB. Moreover, sealed devices feature nearly the same SPL response as the initial counterpart in the frequency band from 100 Hz to 16 kHz and a total harmonic distortion (THD) of 0.728% at 1 kHz for a 40 Vpp driving voltage. Compared with existing sealing methods, the current approach offers easy operation, low damage risk, excellent repeatability/reliability and excellent robustness advantages and provides a promising technical solution for MEMS acoustic devices.
19 May 2025 in Microsystems & Nanoengineering
Despite of good performance immunity to stress and high transmitting/receiving sensitivity advantages, the fabrication imperfection induced asynchronous vibration and the resultant prolonged ring-down tail severely limit the potential of the cantilever beam-based piezoelectric micromachined ultrasonic transducer (PMUT) in pulse-echo applications as transceiver. To address this issue, a novel post processing soft interconnecting strategy is presented. In this case, specific reservoir structure is intentionally integrated into the cantilever-beam based PMUT design, under the assistance of which the liquid PDMS can be accurately applied and spontaneously driven to seal the air gaps between the already released cantilever beams via the capillary effect. After curing, the PDMS will be transformed from liquid to solid and serve as soft interconnecting spring between adjacent cantilever beams so as to force them to vibrate in synchronous mode. At the same time, this treatment does not change the existing fabrication process and has little effect on the original PMUT performance. From both of the mechanical and acoustic response measurement results, effective suppression for the asynchronous vibration and significant reduction of the ring-down tail have been successfully demonstrated for the treated PMUT device. In the subsequent pulse-echo rangefinding experiment, a distance detection range covering from 270.8 mm to 3.8 m with a divergence angle close to 170° has been achieved when it is driven at resonant frequency of 69.2 kHz with 40 Vpp, 40-cycles sinusoidal signal. Given the simple yet effective treatment, the proposed strategy shows great prospective in developing high performance PMUT for in-air rangefinding applications.
7 October 2025 in Measurement
8 April 2026 in SSRN Electronic Journal
In this study, a dual-target self-referential liquid level detection system based on a 2×2 piezoelectric micromachined ultrasonic transducer (PMUT) array and a microcontroller is proposed. It works by simultaneously measuring the sound echo signals reflected from both of the vessel edge as a fixed reference and the changing liquid level in the vessel in real-time through a dynamic peak detection method. By optimizing the horn structure to enhance the PMUT’s emission sensitivity while considering its beamwidth, and designing specific excitation signals to suppress the ring-down vibration of the diaphragm, synergistic enhancement of the axial resolution can be achieved. The proof-of-concept experiment results show that the current system is able to effectively discriminate dual targets for various containers with different materials, sizes and shapes, and the average absolute error of the distance from the liquid level to the vessel edge can be controlled within 1-2 mm in the working range from 8 mm to 225 mm. The proposed system features miniaturization and a high level of integration, and its self-referential dual-target measurement principle provides excellent adaptability for different scenarios, and a highly robust and low-cost practical solution for industrial liquid level detection.