Peter Stacey

Peter Stacey

Auto-generated profile, based on publicly available information

Peter Stacey

The Health and Safety Laboratory, Harpur Hill, Buxton SK17 9JN, UK

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2021 in Annals of Work Exposures and Health
Verified
Journal Article
Closed access
PDF file
SHSamantha Hall
Samantha Hall
PSPeter Stacey
Peter Stacey
IPIan Pengelly
Ian Pengelly
SSStephen Stagg
Stephen Stagg
JSJohn Saunders
John Saunders
SHSusan Hambling
Susan Hambling
The frequency of cases of accelerated silicosis associated with exposure to dust from processing artificial stones is rapidly increasing globally. Artificial stones are increasingly popular materials, commonly used to fabricate kitchen and bathroom worktops. Artificial stones can contain very high levels of crystalline silica, hence cutting and polishing them without adequate exposure controls represents a significant health risk. The aim of this research was to determine any differences in the emission profiles of dust generated from artificial and natural stones when cutting and polishing. For artificial stones containing resins, the nature of the volatile organic compounds (VOCs) emitted during processing was also investigated. A selection of stones (two natural, two artificial containing resin, and one artificial sintered) were cut and polished inside a large dust tunnel to characterize the emissions produced. The inhalable, thoracic, and respirable mass concentrations of emissions were measured gravimetrically and the amount of crystalline silica in different size fractions was determined by X-ray diffraction. Emissions were viewed using scanning electron microscopy and the particle size distribution was measured using a wide range aerosol spectrometer. VOCs emitted when cutting resin-artificial stones were also sampled. The mass of dust emitted when cutting stones was higher than that emitted when polishing. For each process, the mass of dust generated was similar whether the stone was artificial or natural. The percentage of crystalline silica in bulk stone is likely to be a reasonable, or conservative, estimate of that in stone dust generated by cutting or polishing. Larger particles were produced when cutting compared with when polishing. For each process, normalized particle size distributions were similar whether the stone was artificial or natural. VOCs were released when cutting resin-artificial stones. The higher the level of silica in the bulk material, the higher the level of silica in any dust emissions produced when processing the stone. When working with new stones containing higher levels of silica, existing control measures may need to be adapted and improved in order to achieve adequate control.

16 June 2009 in Annals of Work Exposures and Health
Verified
Journal Article
Open access
PDF file
PSPeter Stacey
Peter Stacey
EKEdmond Kauffer
Edmond Kauffer
JMJean-Claude Moulut
Jean-Claude Moulut
CDChantal Dion
Chantal Dion
MBMartin Beauparlant
Martin Beauparlant
DWDerrick Wake
Derrick Wake
It is important that analytical results, produced to demonstrate compliance with exposure limits are comparable, to ensure controls are monitored to similar standards. Correcting a measurement result of respirable α-quartz for the percentage of crystalline material in the calibration dust is good analytical practice and significant changes in the values assigned to calibration materials will affect the interpretation of results by an analyst or occupational hygiene professional. The reissue of the certification for the quartz reference material NIST 1878a in 2005 and differences in comparative values obtained by other work created uncertainty about the values of crystallinity assigned to national calibration dusts for α-quartz. Members of an International Organization for Standardization working group for silica measurement ISO/TC146/SC2/WG7 collaborated to investigate the comparability of results by X-ray diffraction (XRD) and to reach a consensus. This paper lists the values recommended by the working group for use with XRD analysis. The values for crystallinity obtained for some of the materials (NIST 1878, Min-U-Sil5 and A9950) were 6–7% lower than the original certification or estimates reported in other comparisons. Crystallinity values obtained by XRD gave a good correlation with BET surface area measurements (r2 = 0.91) but not with mean aerodynamic particle size (r2 = 0.31). Subsamples of two of the materials (A9950 Respirable and Quin 1 Respirable) with smaller particle size distribution than their parent material did not show any significant change in their values for crystallinity, suggesting that the area XRD measurement of these materials within the particle size range collected is more dependent on how the quartz is formed geologically or how it is processed for use. A comparison of results from laboratories using the infrared (IR) and KBr disc method showed that this method is more dependent than XRD on differences in the particle size within the respirable size range, whereas the XRD values were more consistent between the different measurement values obtained on each material. It was not possible to assign a value for percentage purity to each material for users of IR analysis. This work suggests that differences are likely to exist between the results from XRD and IR analysis when measuring ‘real’ workplace samples and highlights the importance of matching the particle size of the calibration material to the particle size of the workplace dust for measurements of crystalline quartz.

3 May 2021 in Journal of Raman Spectroscopy
Verified
Journal Article
Open access
PDF file
PSPeter Stacey
Peter Stacey
SHSamantha Hall
Samantha Hall
SSStephen Stagg
Stephen Stagg
FCFrancis Clegg
Francis Clegg
Chris SammonChris Sammon
Chris Sammon
Around 560 000 workers in Great Britain are potentially exposed to respirable crystalline silica (RCS), which can cause disabling diseases, such as silicosis and lung cancer. These experiments assessed the performance of a new Raman spectroscopy method for measuring RCS, in samples of pure quartz powder with different median aerodynamic particle diameters and stone dusts from variety of natural and artificial stones. The relationship between the Raman response and particle size was characterised by measuring subfractions of the respirable quartz standard A9950 collected using the Sioutas impactor. Bulk samples of quartz standards A9950 and Quin B that provided the highest median particle size diameters were also measured. Health‐related thoracic and respirable particle size fractions, and the environmental monitoring fractions of PM10, PM2.5, PM1 and PM0.5, were also collected during the powered cutting and polishing of sandstone and diorite (granite), engineered and sintered stones. All Raman spectroscopy results were compared with those from X‐ray diffraction (XRD), which was used as the reference technique. The Raman spectroscopy response closely followed the predicted crystallinity of RCS for different particle diameters. Raman spectroscopy obtained slightly higher percentages than XRD for particle size fractions below 1 μm. The Raman spectroscopy and XRD results were highly correlated for the thoracic, respirable and impactor fractions. The coefficients of determination were between 0.98 and 0.95. The slope coefficients for the correlation were 1.11 for the respirable fraction and 1.07 for the thoracic fraction. Raman spectroscopy is a promising alternative to XRD for measurement of RCS with a much lower limit of detection of 0.21 μg compared with 1 μg.

20 February 2017 in Journal of Raman Spectroscopy
Verified
Journal Article
Open access
PDF file
PSPeter Stacey
Peter Stacey
KMKerstin T. Mader
Kerstin T. Mader
Chris SammonChris Sammon
Chris Sammon
Airborne respirable crystalline silica (RCS) is a hazard that can affect the health of workers, and more sensitive measurements are needed for the assessment of worker exposure. To assess the use of Raman microscopy for the analysis of RCS particulate collected on filters, aliquots of quartz or cristobalite suspended in isopropanol were pipetted onto silver filters. Samples were measured by arbitrarily selecting positions along the filter and collecting spectra at 50 discrete points. The calculated limits of quantification on test samples were between 0.066–0.161 and 0.106–0.218 μg for quartz and cristobalite, respectively. Three respirable quartz calibration dusts (A9950, NIST 1878 and Quin 1B) with different mass median aerodynamic particle sizes obtained similar Raman response relationships per unit mass. The difference between NIST 1878 and Quin 1B was not significant (p = 0.22). The intermediate measurement precision of replicate samples was 10–25% over the measured range for quartz (0.25–10 μg) and could potentially be improved. Results from mixtures of quartz and cristobalite were mostly within 10% of their theoretical values. Results from samples of 6% quartz in calcite were close to the theoretical quartz mass. The upper measurement limit for a mixture of 20% RCS in the light absorbing mineral hematite (Fe2O3) was 5 μg. These data show that Raman spectroscopy is a viable option for the quantification of the mass of respirable crystalline silica on filters with a limit of detection approaching 1/10th of that obtained with other techniques. The improvement in sensitivity may enable the measurement of particulate in samples from low concentration environments (e.g. inside a mask) or from miniature samplers operating at low flow rates. ©2017 Crown copyright. Journal of Raman Spectroscopy published by John Wiley & Sons, Ltd. © 2017 Crown copyright. Journal of Raman Spectroscopy published by John Wiley & Sons, Ltd.


27 January 2014 in Annals of Work Exposures and Health
Verified
Journal Article
Open access
PDF file
PSPeter Stacey
Peter Stacey
TLTaekhee Lee
Taekhee Lee
ATAndrew Thorpe
Andrew Thorpe
PRPaul Roberts
Paul Roberts
GFGillian Frost
Gillian Frost
MHMartin Harper
Martin Harper
Prolonged exposure to respirable crystalline silica (RCS) causes silicosis and is also considered a cause of cancer. To meet emerging needs for precise measurements of RCS, from shorter sampling periods (<4h) and lower air concentrations, collaborative work was done to assess the differences between personal respirable samplers at higher flow rates. The performance of FSP10, GK2.69, and CIP 10 R samplers were compared with that of the Safety In Mines Personal Dust Sampler (SIMPEDS) sampler as a reference, which is commonly used in the UK for the measurement of RCS. In addition, the performance of the FSP10 and GK 2.69 samplers were compared; at the nominal flow rates recommended by the manufacturers of 10 and 4.2 l · min−1 and with flow rates proposed by the National Institute for Occupational Safety and Health of 11.2 and 4.4 l · min−1. Samplers were exposed to aerosols of ultrafine and medium grades of Arizona road dust (ARD) generated in a calm air chamber. All analyses for RCS in this study were performed at the Health and Safety Laboratory. The difference in flow rates for the GK2.69 is small and does not result in a substantial difference in collection efficiency for the dusts tested, while the performance of the FSP10 at 11.2 l · min−1 was more comparable with samples from the SIMPEDS. Conversely, the GK2.69 collected proportionately more crystalline silica in the respirable dust than other samplers, which then produced RCS results most comparable with the SIMPEDS. The CIP 10 R collected less ultrafine ARD than other samplers, as might be expected based on earlier performance evaluations. The higher flow rate for the FSP10 should be an added advantage for task-specific sampling or when measuring air concentrations less than current occupational exposure limits.