23 October 2019 in IEEE Access
This paper addresses a linearized interactive dispatching model developed between active distribution network (ADN) and virtual micro-grid (VMG). To make such concept, a bi-level framework is adopted based on the analytical target cascading (ATC) method. In this model, the lower level dispatches each element in VMG from the standpoint of VMG's own interests, and an objective function of maximizing the VMG's benefits is constructed. The upper level dispatches each element in ADN from the perspective of ADN's economy and reliability, on this basis, a synthetic objective function is built. In addition, the ACT method is used to solve the coupling problem caused by the existence of interaction variables between the upper and lower levels, and ultimately to achieve win-win cooperation between ADN and VMG levels. Moreover, to reduce the computational complexity of the model and speed up the solving process, the second-order cone programming is employed in the proposed model to linearize the power flow calculation of the distribution network. Finally, simulation studies are conducted on the IEEE 18-bus distribution test systems to illustrate the feasibility of the proposed model. The stability and effectiveness of the model are verified by various comparisons.
30 April 2022 in Sustainable Energy, Grids and Networks
27 October 2023 in IEEE Transactions on Neural Networks and Learning Systems
With the advent of the data era, most power secondary side equipment tends to be digitized. The power system needs more accurate numerical results to further improve its operating efficiency. Therefore, it is important to study the electromagnetic interferences of very fast transient overvoltage (VFTO) generated by gas-insulated switchgear (GIS). To protect the secondary side cable from interferences, the secondary side cable is wrapped with an outer shield and the shield is grounded. When the interference of VFTO comes, it will couple the interference current and interference voltage on the shield of the cable. By grounding, the interference is greatly discharged. However, due to the grounding resistance, there will be a potential difference between the grounding points at the two ends of the shield of the cable. This causes a corresponding interference current to flow through the shield, which will affect the transmission of signals inside the cable. In the actual substation, the resistivity of the soil, the ambient temperature and humidity of the area, and so on will have impacts on the grounding resistance. In addition, the irregularity of the cable arrangement and the time of the use of the cable will have impacts on the signal transmission of the cable. Based on the abovementioned issues, this article proposed a comprehensive assessment method based on the combination of the cloud model and measurement of alternatives and ranking according to compromise solution (MARCOS). The method brings the cloud model into MARCOS by the algorithm of the contribution of the cloud droplets. It overcomes the difficulty of cloud model quantification. By comparing the results of the proposed method with the actual conditions at the substation and the results of the common MARCOS assessment method, the validity of the method is verified, and a reference scheme is provided for substation optimization.