Mohamed M. El-Shafhy

Mohamed M. El-Shafhy

Auto-generated profile, based on publicly available information

Mohamed M. El-Shafhy

Electrical Power and Machines Department, High Institute of Engineering, El-Shorouk Academy, El Shorouk City, Cairo, Egypt

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2022 in IEEE Access
Verified
Journal Article
Open access
AAAlaa M. Abdel-hamed
Alaa M. Abdel-hamed
MEMohamed M. El-Shafhy
Mohamed M. El-Shafhy
EBEbrahim A. Badran
Ebrahim A. Badran
Aberrant system oscillations cause electrical network components to malfunction in a catastrophic way. Additionally, this results in saturation of the ferromagnetic core components. These variables cause a significant increase in voltage and/or current, as well as aberrations in the waveforms of voltage and current. The contribution of Distributed Generation (DG), to the decrease in ferroresonance investigation in the distribution zone, is discussed in this paper. A new method to reduce ferroresonance using the High Ohmic Reactor(HOR) as a Shunt Limiter (SL) is presented. It is based on the measurements of the negative-sequence components. The proposed HOR-SL reduced the ferroresonance occurrence in the Distribution System (DS) by a time value of no more than 23 milliseconds. The proposed HOR-SL method is compared with the Series Resistance (SR) and Series Tuned LC Limiter (STLCL) methods. The results obtained using the proposed HOR-SL are better than the ones obtained using SE and STLCL. In terms of the voltage and the time taken to mitigate the ferroresonance. The ferroresonance phenomenon is modelled with the help of the PSCAD/EMTDC software. The results obtained demonstrated the effectiveness of implementing the suggested HOR-SL for suppressing ferroresonant oscillations to restore the original state of stability of the distribution network. Case studies proved the effectiveness and robustness of the proposed method in reducing ferroresonance oscillations and maintaining the security distribution network.

1 December 2022 in Indonesian Journal of Electrical Engineering and Computer Science
Verified
Journal Article
Open access
PDF file
AAAlaa M. Abdel-hamed
Alaa M. Abdel-hamed
MEMohamed M. El-Shafhy
Mohamed M. El-Shafhy
EBEbrahim A. Badran
Ebrahim A. Badran
Electrical network components catastrophically fail as a result of aberrant system oscillations. Also, consequently leads to saturation in the ferromagnetic core elements. These factors induce distortions in the voltage and current waveforms as well as a large rise in voltage or current. This paper presents the role of distributed generation (DG) in contributing to ferroresonance investigation reduction in the distribution sector. A high ohmic reactor-shunt limiter (HOR-SL) is introduced as a novel technique based on a negative sequence component to mitigate ferroresonance. The proposed HOR-SL reduces the ferroresonance in distribution system (DS) by no more than 10.5 msec. A PSCAD/EMTDC software is used to model the ferroresonance phenomenon. The simulation results strongly show the effectiveness of using the proposed HOR-SL for limiting ferroresonant oscillations and creating stable orbit in the distribution sector. Case studies verified the effectiveness of the proposed technique in mitigating ferroresonance oscillations and keeping the security of the distribution zone.