Commissioning of detector systems for the High-Luminosity Large Hadron Collider (HL-LHC) is scheduled to take place between 2026 and 2028 at CERN. Application Specific Integrated Circuits (ASICs) for those systems have been in intense development over the past ten years. Some of those ASICs, as is the case of the Low Power GigaBit Transceiver (lpGBT) described in this work, have now been produced in industrial quantities and have been fully qualified for operation in the HL-LHC environments that require, where the innermost detectors are concerned, radiation hardness in excess of 1 MGy. The lpGBT is a multi-functional device, enabling data transmission between the off-detector and the on-detector systems. Data can be transmitted from the detector at 5.12 Gbit s −1 and 10.24 Gbit s −1 and to the detector at 2.56 Gbit s −1 . It implements data rate-configurable electrical links to communicate with the front-end ASICs and low-speed serial and parallel buses for experiment control. A set of analog functions for monitoring and control of the physics detectors is also included. This paper describes the functionality and the architecture of the lpGBT ASIC and reports on its radiation hardness characterization.
30 January 2023 in IEEE Transactions on Nuclear Science
The high luminosity expected in the second phase of the upgrades of the Large Hadron Collider (LHC phase-2 upgrades) will pose unprecedented challenges to its four experiments in terms of collisions density – also known as pileup – per beam crossing. Disentangling the vertices of 200 simultaneous collisions every 25 ns requires high granularity in the detectors, as well as extremely precise and stable timing. While short-term timing stability is usually a concern addressed in timing distribution systems, long-term variations due to changing environmental conditions can accumulate through distribution chains and can dominate the overall timing stability of the systems they serve. Timing distribution systems in LHC experiments typically use high-speed links and clock recovery. This paper presents a logic core that can be used to mitigate long-term temperature variations in high-speed links. The Timing Compensated Link (TCLink) is an open-source firmware core fully integrated in Xilinx Ultrascale Field Programmable Gate Arrays (FPGAs). It demonstrates picosecond-level phase precision over timing distribution systems, improving the overall timing stability in physics experiments.
A high-quality, low-cost ventilator, dubbed HEV, has been developed by the particle physics community working together with biomedical engineers and physicians around the world. The HEV design is suitable for use both in and out of hospital intensive care units, provides a variety of modes and is capable of supporting spontaneous breathing and supplying oxygen-enriched air. An external air supply can be combined with the unit for use in situations where compressed air is not readily available. HEV supports remote training and post market surveillance via a Web interface and data logging to complement standard touch screen operation, making it suitable for a wide range of geographical deployment. The HEV design places emphasis on the ventilation performance, especially the quality and accuracy of the pressure curves, reactivity of the trigger, measurement of delivered volume and control of oxygen mixing, delivering a global performance which will be applicable to ventilator needs beyond the COVID-19 pandemic. This article describes the conceptual design and presents the prototype units together with a performance evaluation.
Picosecond-level phase determinism in timing distribution systems is a requirement for future detectors in High Energy Physics. FPGA transceivers traditionally used to propagate timing signals generally do not meet this stringent requirement, suffering from phase jumps at startup and from drifts due to temperature variations. While ad hoc solutions have been developed using FPGA features to measure and correct for phase shifts, they remain FPGA specific and therefore cannot be generalized to all types of timing links. This paper presents a study using discrete components to monitor and correct for phase drift, allowing for an implementation of a generic deterministic link.
The Large Hadron Collider (LHC) uses timing, trigger and control (TTC) system backbone to distribute the bunch clock and other critical timing signals to all the participating experiments. The clock signal is directly derived from the radio frequency (RF) driving the beams in the accelerator. The whole range of electronic systems from an ADC to high-speed transmission link works in synchronous to the clock signal and are sensitive to jitter. Throughout the clock distribution chain, high-frequency components increase the jitter. Multiple Phase-Locked Loops (PLLs) are used in the entire chain to maintain the jitter noise at a minimum level. Si5344 PLL by Silicon Labs is chosen as one of the candidate PLLs for jitter cleaning of the embedded clock in LHC gigabit serial link transmission. The article aims to highlight the qualification tests conducted to characterize the PLL component. Laboratory test setup is built to emulate the thermal variation of the LHC as in run-time condition. The present research study investigates the influence of temperature variation on PLL jitter-cleaning performance when operated in different configuration modes needed in TTC distribution chain. Stability of the PLL circuitry to lock correctly with repetitive reset assertion, power on/off cycle and marginal frequency swing about the LHC bunch clock mean frequency value is also studied.