Laurence C. Chow

Laurence C. Chow

Auto-generated profile, based on publicly available information

Laurence C. Chow

National Institute of Standards and Technology

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2010 in Journal of Research of the National Institute of Standards and Technology
Verified
Journal Article
Closed access
LSLimin Sun
Limin Sun
LCLaurence C. Chow
Laurence C. Chow
SFStanislav Frukhtbeyn
Stanislav Frukhtbeyn
JBJohn E. Bonevich
John E. Bonevich
This study aimed at preparing and studying the properties of nanoparticles of calcium phosphate (nCaP) with Ca/P ratios ranging from 1.0 to 1.67 using a spray-drying technique. Micro-structural analyses suggested that the nCaPs with Ca/P ratios of 1.67 to 1.33 were nano-sized amorphous calcium phosphate (ACP) containing varying amounts of acid phosphate and carbonate. The nCaP with Ca/P ratio of 1 contained only nano-sized low crystalline dicalcium phosphate (DCP). BET measurements of the nCaPs showed specific surface areas of (12 ± 2 to 50 ± 1) m2/g, corresponding to estimated equivalent spherical diameters of (38 to 172) nm. However, dynamic light scattering measurements revealed much larger particles of (380 ± 49 to 768 ± 111) nm, owing to agglomeration of the smaller primary nano particles as revealed by Scanning Electron Microscopy (SEM). Thermodynamic solubility measurements showed that the nCaPs with Ca/P ratio of 1.33 – 1.67 all have similar solubility behavior. The materials were more soluble than the crystalline hydroxyapatite (HA) at pH greater than about 4.7, and more soluble than β-tricalcium phosphate (β-TCP), octacalcium phosphate (OCP) and DCP at pH above 5.5. Their solubility approached that of α-tricalcium phosphate (α-TCP) at about pH 7. These nCaPs, which cannot be readily prepared by other currently available methods for nanoparticle preparation, have potential biomedical applications.

27 January 2012 in Journal of Biomaterials Applications
Verified
Journal Article
Open access
PDF file
Murugan RamalingamMurugan Ramalingam
Murugan Ramalingam
MYMarian Frances Young
Marian Frances Young
Vinoy ThomasVinoy Thomas
Vinoy Thomas
SLSun Limin
Sun Limin
LCLaurence C Chow
Laurence C Chow
CSCarl Simon
Carl Simon
We have designed a 2-spinnerette device that can directly electrospin nanofiber scaffolds containing a gradient in composition that can be used to engineer interfacial tissues such as ligament and tendon. Two types of nanofibers are simultaneously electrospun in an overlapping pattern to create a nonwoven mat of nanofibers containing a composition gradient. The approach is an advance over previous methods due to its versatility – gradients can be formed from any materials that can be electrospun. A dye was used to characterize the 2-spinnerette approach and applicability to tissue engineering was demonstrated by fabricating nanofibers with gradients in amorphous calcium phosphate nanoparticles (nACP). Adhesion and proliferation of osteogenic cells (MC3T3-E1 murine pre-osteoblasts) on gradients was enhanced on the regions of the gradients that contained higher nACP content yielding a graded osteoblast response. Since increases in soluble calcium and phosphate ions stimulate osteoblast function, we measured their release and observed significant release from nanofibers containing nACP. The nanofiber-nACP gradients fabricated herein can be applied to generate tissues with osteoblast gradients such as ligaments or tendons. In conclusion, these results introduce a versatile approach for fabricating nanofiber gradients that can have application for engineering graded tissues.

1 September 2011 in Journal of Research of the National Institute of Standards and Technology
Verified
Journal Article
Closed access
TWTongxin Wang
Tongxin Wang
LCLaurence C. Chow
Laurence C. Chow
SFStanislav A. Frukhtbeyn
Stanislav A. Frukhtbeyn
ATAndy Hai Ting
Andy Hai Ting
QDQuanxiao Dong
Quanxiao Dong
JMJames W. Mitchell
James W. Mitchell
Bioresorbable composite made from degradable polymers, e.g., polylactide (PLA), and bioactive calcium phosphates, e.g., hydroxyapatite (HA), are clinically desirable for bone fixation, repair and tissue engineering because they do not need to be removed by surgery after the bone heals. However, preparation of PLA/HA composite from non-modified HA usually results in mechanical strength reductions due to a weak interface between PLA and HA. In this study, a calcium-phosphate/phosphonate hybrid shell was developed to introduce a greater amount of reactive hydroxyl groups onto the HA particles. Then, PLA was successfully grafted on HA by surface-initiated polymerization through the non-ionic surface hydroxyl groups. Thermogravimetric analysis indiated that the amount of grafted PLA on HA can be up to 7 %, which is about 50 % greater than that from the literature. PLA grafted HA shows significantly different pH dependent ζ-potential and particle size profiles from those of uncoated HA. By combining the phosphonic acid coupling agent and surface initiated polymerization, PLA could directly link to HA through covalent bond so that the interfacial interaction in the PLA/HA composite can be significantly improved. The diametral tensile strength of PLA/HA composite prepared from PLA-grafted HA was found to be over twice that of the composite prepared from the non-modified HA. Moreover, the tensile strength of the improved composite was 23 % higher than that of PLA alone. By varying additional variables, this approach has the potential to produce bioresorbable composites with improved mechanical properties that are in the range of natural bones, and can have wide applications for bone fixation and repair in load-bearing areas.

1 June 2004 in Topics in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
DMDaniel Jason Aaron Margolis
Daniel Jason Aaron Margolis
RBRoland Bammer
Roland Bammer
LCLawrence C Chow
Lawrence C Chow
Parallel imaging holds great potential for improving the quality of diagnostic abdominal MRI. The increased imaging speed afforded by parallel imaging can be translated into the obvious benefits of reduced scan time with set resolution and coverage, improved spatial resolution with set imaging time and coverage, increased anatomic coverage for a set imaging time and resolution, or some combination of the above. Additionally, the reduction in scan time can also allow some sequences that normally require multiple breath-holds to be performed with only one, or simply make breath-hold imaging possible for more patients. The decreased echo-train length allows for truer T2-weighting, less magnetic susceptibility artifact, and less blurring with echo-train imaging. Dynamic contrast-enhanced sequences can be acquired with improved temporal or spatial resolution. All of these potential advantages come with the trade-off of decreased signal-to-noise ratio, but for many patients, the benefits far outweigh the drawbacks and can vastly improve the diagnostic quality of abdominal MRI.

1 July 2010 in Journal of Research of the National Institute of Standards and Technology
Verified
Journal Article
Closed access
MMM. Markovic
M. Markovic
LCL. C. Chow
L. C. Chow
The osteoconductive and possibly osteoinductive characteristics of OCP increased the interest in preparation of bone graft materials that contain OCP in its composition. Calcium phosphate cements (CPCs) were prepared using a mixture of α-tricalcium phosphate (α-TCP) and dicalcium phosphate anhydrous (DCPA), with α-TCP/DCPA molar ratio of 1/1 and distilled water or 0.5 mol/L phosphate aqueous solution (pH = 6.1 ± 0.1) as the cement liquid. Hardening time was (30 ± 1) min for the CPC mixed with water and (5 ± 1) min for the CPC mixed with phosphate solution. Diametral tensile strength (DTS), porosity (P), and phase composition (powder x-ray diffraction) were determined after the hardened specimens had been immersed in a physiological-like solution (PLS) for 1 d, 3 d, and 7 d. In CPC specimens prepared with water, calcium hydroxyapatite (HA) was formed and DTS and P were (9.03 ± 0.48) MPa and (37.05 ± 0.20) vol % after 1 d, respectively, and (9.15 ± 0.45) MPa and (37.24 ± 0.63) vol % after 3 d, respectively. In CPC specimens prepared with phosphate solution OCP and HA were formed and DTS and P were (4.38 ± 0.49) MPa and (41.44 ± 1.25) vol % after 1 d, respectively,(4.38 ± 0.29) MPa and (42.52 ± 2.15) vol % after 3 d, respectively, and (4.30 ± 0.60) MPa and (41.38 ± 1.65) vol % after 7 d, respectively. For each group DTS and P did not change with PLS immersion time. DTS was significantly higher and P was significantly lower for CPCs prepared with water. HA formation slightly increased with immersion time from 40 mass % after 1 d to 50 mass % after 3 d in CPCs prepared with water. OCP + HA formation increased with immersion time from 30 mass % after 1 d to 35 mass % after 3 d and to 45 mass % after 7 d in CPCs prepared with 0.5 mol/L phosphate solution.

1 June 1996 in Journal of Materials Science
Verified
Journal Article
Closed access
PDF file
SMS. Matsuya
S. Matsuya
STS. Takagi
S. Takagi
LCL. C. Chow
L. C. Chow