1 January 2019 in Korean Journal of Neurotrauma
Shim YW, et al. Korean J Neurotrauma. 2019 Jul;15:e25. https://doi.org/10.13004/kjnt.2019.15.e25
1 January 2013 in Journal of Cerebrovascular and Endovascular Neurosurgery
The aim of this study is to introduce a microvascular training model based on use of materials that can be easily obtained from the daily surroundings. Simple microinstruments and a medical school laboratory microscope were used for anastomosis training. Chicken blood vessels were used as a material for this study. A long segment of blood vessel from the proximal brachial artery to the distal radial artery was used for training. End-to-side anastomosis was practiced first, and the training continued with end-to-end anastomosis of the appropriate segments. The instruments used for setting up this model were simple and easy to use; therefore, the time required for preparation of the materials and dissection of the chicken wings was only approximately five to ten minutes. The characteristics of 20 chicken wings were analyzed. The length of the brachial artery to the radial artery was 8 - 10 cm. The average diameter of the brachial artery was 1.3 mm ± 0.2 mm and that of the radial artery was 1.0 mm ± 0.2 mm. Taking advantage of these characteristics, the proximal brachial artery was grafted to the radial artery for practice of end-to-side anastomosis. This study suggests an effective and feasible method for microvascular anastomosis training using chicken wing arteries and simple microinstruments. This model may simulate the conditions of a superficial temporal artery to middle cerebral artery anastomosis surgery.
11 April 2019 in American Journal of Neuroradiology
BACKGROUND AND PURPOSE: Time-of-flight MR angiography, though widely used after coil embolization, is associated with limitations owing to magnetic susceptibility and radiofrequency shielding following stent-assisted coil embolization. We evaluated the pointwise encoding time reduction with radial acquisition (PRETRA) sequence in subtraction-based MRA (qMRA) using an ultrashort TE relative to TOF-MRA during the follow-up of stent-assisted coil embolization for anterior circulation aneurysms. MATERIALS AND METHODS: Twenty-five patients (3 men and 22 women; mean age, 59.1 ± 14.0 years) underwent stent-assisted coil embolization for anterior circulation aneurysms and were retrospectively evaluated using TOF-MRA and PETRA qMRA data from the same follow-up session. Two neuroradiologists independently reviewed both MRA findings and subjectively graded flow within the stents (relative to the latest DSA findings) and occlusion status (complete occlusion or neck/aneurysm remnant). Interobserver and intermodality agreement for TOF-MRA and PETRA qMRA were evaluated. RESULTS: The mean score for flow visualization within the stents was significantly higher in PETRA qMRA than in TOF-MRA (P < .001 for both observers), and good interobserver agreement was reported (κ = 0.63). The aneurysm occlusion status of PETRA qMRA (observer 1, 92.0%; observer 2, 88.0%) was more consistent with DSA than with TOF-MRA (observer 1, 76.0%; observer 2, 80.0%), and there was a better intermodality agreement between DSA and PETRA qMRA than between DSA and TOF-MRA. CONCLUSIONS: These findings indicate that PETRA qMRA is a useful follow-up technique for patients who have undergone stent-assisted coil embolization for anterior circulation aneurysms.
11 September 2015 in International Journal of Concrete Structures and Materials
Friction in a post-tensioning system has a significant effect on the distribution of the prestressing force of tendons in prestressed concrete structures. However, attempts to derive friction coefficients using conventional electrical resistance strain gauges do not usually lead to reliable results, mainly due to the damage of sensors and lead wires during the insertion of strands into the sheath and during tensioning. In order to overcome these drawbacks of the existing measurement system, the Smart Strand was developed in this study to accurately measure the strain and prestressing force along the strand. In the Smart Strand, the core wire of a 7-wire strand is replaced with carbon fiber reinforced polymer in which the fiber Bragg grating sensors are embedded. As one of the applications of the Smart Strand, friction coefficients were evaluated using a full-scale test of a 20 m long beam. The test variables were the curvature, diameter, and filling ratio of the sheath. The analysis results showed the average wobble and curvature friction coefficients of 0.0038/m and 0.21/radian, respectively, which correspond to the middle of the range specified in ACI 318-08 in the U.S. and Structural Concrete Design Code in Korea. Also, the accuracy of the coefficients was improved by reducing the effective range specified in these codes by 27–34 %. This study shows the wide range of applicability of the developed Smart Strand system.
30 September 2020 in Journal of Cerebrovascular and Endovascular Neurosurgery
Microsurgical treatment could be a good alternative for the treatment of recurrent cerebral aneurysm after coil embolization. The purpose of this study was to present our experience of microsurgical treatment for recurrent cerebral aneurysm previously treated using coil embolization. From June 2012 to May 2019, 34 patients consecutively received microsurgical treatment for a recurrent cerebral aneurysm previously treated using coil embolization after it ruptured. Of the 34 patients with aneurysm, 33 had the aneurysm located in the anterior circulation. The most common location was the anterior communicating artery (13 cases). Immediate radiologic outcome at coil embolization was completed (n=6), residual neck (n=26), and residual sac (n=2). The reason for microsurgical treatment included rebleeding (n=12), persistent residual sac (n=1), and recurrence on follow-up study (n=21). Rebleeding occurred within 10 days after coil embolization in 10 cases, and the other 2 were due to regrowth. In the 20 recurred and saccular aneurysms, coil compaction was present in 11 aneurysms and regrowth in 9 aneurysms. Simple neck clipping (n=29) and clipping with coil mass extraction (n=3) was possible in the saccular aneurysms. The blood blister like aneurysm (n=2) were treated using bypass and endovascular internal carotid artery trapping. In the follow-up study group after microsurgical treatment there were no severe complications due to the treatment. Age, cause of retreatment, and modified Rankin Scale before microsurgery were associated with good outcome (p<0.001). Microsurgical treatment may be a viable and effective option for treating recurrent aneurysms previously treated by endovascular techniques.
1 January 2020 in Korean Journal of Neurotrauma
Lee JH, et al. Korean J Neurotrauma. 2020 Feb;16:e4. https://doi.org/10.13004/kjnt.2020.16.e4