16 October 2019 in Wind Engineering
The assessment of climatological site conditions, airflow characteristics, and the turbulence affecting wind turbines is an important phase in developing wake engineering models. A method of modeling atmospheric boundary layer structure under atmospheric stability effects is crucial for accurate evaluation of the spatial scale of modern wind turbines, but by themselves, they are incapable to account for the varying large-scale weather conditions. As a result, combining lower atmospheric models with mesoscale models is required. In order to realize a reasonable approximation of initial atmospheric inflow condition used for wake identification behind an NREL 5-MW wind turbine, different vertical wind profile models on equilibrium conditions are tested and evaluated in this article. Wind farm simulator solvers require massive computing resources and forcing mechanisms tendencies inputs from weather forecast models. A three-dimensional Flow Redirection and Induction in Steady-state engineering model was developed for simulating and optimizing the wake losses of different rows of wind turbines under different stability stratifications. The obtained results were compared to high-fidelity simulation data generated by the famous Simulator for Wind Farm Applications. This work showed that a significant improvement related to atmospheric boundary layer structure can be made to develop accurate engineering wake models in order to reduce wake losses.
3 September 2026 in Wind Engineering
Rigid one-mass drivetrain models simplify maximum power point tracking (MPPT) controller synthesis, but their use can create a model-controller mismatch when the implemented wind turbine has a flexible shaft. This study evaluates that mismatch using a nonlinear MATLAB/Simulink model of a 1.5 MW variable-speed horizontal-axis wind turbine. Three PI-based cases are compared: (A) a controller tuned with a one-mass model and applied to a two-mass plant, (B) a controller tuned with the two-mass plant, and (C) the matched controller supplemented by active torsional damping. The gains are selected from linearized one-mass and two-mass models using pole-placement and frequency-domain constraints, while identical saturation and anti-windup settings are retained. The controllers are tested for 60 s under a reproducible wind profile with a mean speed of 11.6 m/s, deterministic low- and medium-frequency components, a gust, and low-intensity random turbulence (sigma = 0.20 m/s; turbulence intensity approximately 1.7%). Under these specific conditions, the three cases yield 0.004125 MWh, a mean absolute generator-speed tracking error of 2.14 rad/s, a tracking-error standard deviation of 4.36 rad/s, and a maximum low-speed-shaft torque of 10.924 MN m. No amplified peak is observed near the calculated torsional frequency. The contribution is therefore a conditional counterexample and a reproducible benchmark showing that rigid-model tuning is not necessarily destabilizing for this parameter set. It is not a general proof of safety: the result is limited to the tested turbine, PI architecture, short simulation horizon, high inherent damping, and low turbulence level.