Mohamed Tahiri

Dr. Mohamed Tahiri

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2026 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
MTMohamed Tahiri
Mohamed Tahiri
LYLakhal Yassine
Lakhal Yassine
SLSoulaiman Louah
Soulaiman Louah
AMAbdelaziz Mimet
Abdelaziz Mimet
The following is a detailed account of how the flexibility of a drive train affects maximum power point tracking (MPPT) for wind turbines. The study uses the National Renewable Energy Laboratory 5 MW reference turbine as a base model with Kaimal spectrum having felt waves creating turbulent winds. This study compares both rigid and flexible drive trains that undergo identical turbulence conditions (average wind speed 9.0 m/s and flight weather turbulence, 16% T.I.). The results show that the flexible unit provides an 8.95 percent area increase in mean power coefficient, (p < 0.001, Cohen’s d = 2.108) while the rigid unit produces a 4173 percent (p < 10−47, Cohen’s d = 31.8) sudden rise in power during catastrophic loss of control and produce a direct torque oscillation of over 153 MN·m RMS between the two configurations. The conclusion of this research establishes that PID Controllers that are manually tuned based on measurements taken with rigid drive trains cannot be used with flexible drivetrains. Therefore, it is necessary to either re-tune the PID Controller quickly after switching between form of drive train; and/or implement advanced control strategies to effectively manage these situations in the future. This study shows that rigid-model assumptions are fundamentally inadequate for contemporary turbine control design, which directly results in decreased energy yield. The findings necessitate a paradigm shift towards control strategies that specifically take structural dynamics into consideration in order to produce vibration-resilient MPPT for next-generation turbines.

3 September 2026 in Wind Engineering
Verified
Journal Article
Closed access
MTMohamed Tahiri
Mohamed Tahiri
YLYassine Lakhal
Yassine Lakhal
SLSoulaiman Louah
Soulaiman Louah
MIMohamed Marouan Ichenial
Mohamed Marouan Ichenial
Rigid one-mass drivetrain models simplify maximum power point tracking (MPPT) controller synthesis, but their use can create a model-controller mismatch when the implemented wind turbine has a flexible shaft. This study evaluates that mismatch using a nonlinear MATLAB/Simulink model of a 1.5 MW variable-speed horizontal-axis wind turbine. Three PI-based cases are compared: (A) a controller tuned with a one-mass model and applied to a two-mass plant, (B) a controller tuned with the two-mass plant, and (C) the matched controller supplemented by active torsional damping. The gains are selected from linearized one-mass and two-mass models using pole-placement and frequency-domain constraints, while identical saturation and anti-windup settings are retained. The controllers are tested for 60 s under a reproducible wind profile with a mean speed of 11.6 m/s, deterministic low- and medium-frequency components, a gust, and low-intensity random turbulence (sigma = 0.20 m/s; turbulence intensity approximately 1.7%). Under these specific conditions, the three cases yield 0.004125 MWh, a mean absolute generator-speed tracking error of 2.14 rad/s, a tracking-error standard deviation of 4.36 rad/s, and a maximum low-speed-shaft torque of 10.924 MN m. No amplified peak is observed near the calculated torsional frequency. The contribution is therefore a conditional counterexample and a reproducible benchmark showing that rigid-model tuning is not necessarily destabilizing for this parameter set. It is not a general proof of safety: the result is limited to the tested turbine, PI architecture, short simulation horizon, high inherent damping, and low turbulence level.