In magnetic confinement thermonuclear fusion the exhaust of heat and particles from the core remains a major challenge. Heat and particles leaving the core are transported via open magnetic field lines to a region of the reactor wall, called the divertor. Unabated, the heat and particle fluxes may become intolerable and damage the divertor. Controlled ‘plasma detachment’, a regime characterized by both a large reduction in plasma pressure and temperature at the divertor target, is required to reduce fluxes onto the divertor. Here we report a systematic approach towards achieving this critical need through feedback control of impurity emission front locations and its experimental demonstration. Our approach comprises a combination of real-time plasma diagnostic utilization, dynamic characterization of the plasma in proximity to the divertor, and efficient, reliable offline feedback controller design.
This paper presents the LPMLEn, a new method to estimate vertical flux and thermal diffusivity from streambed temperature time series using the frequency domain. The main advantages of this new method are: (a) the use of multiple frequencies and multiple sensors for the parameter estimation; (b) noise/uncertainty handling in an optimal way; (c) the possibility to estimate the parameters with both semi‐infinite and bounded domain models; and (d) the compensation for temperature drifts in the data known as transients. The capabilities of the LPMLEn are demonstrated using both synthetic and field data, highlighting the advantages of the bounded domain model over the semi‐infinite domain model in the parameter estimation process.
The injection of electron cyclotron (EC) waves fulfills a number of important tasks in nuclear fusion devices for which detailed knowledge of the spatial power deposition profile is critical. This deposition profile is commonly determined using forward models such as beam or ray tracing. Recent numerical and experimental studies have shown that small-angle scattering of the EC beam as it passes through the turbulent plasma edge can cause significant broadening of the effective deposition profile, leading to considerable underestimation of the deposition width by forward methods. However, traditional inverse methods to determine the deposition profile from measurements overestimate the deposition profile width due to transport broadening. In this work, we implement three novel methods to resolve the EC power deposition profile from measurements that counteract transport broadening by simultaneously resolving transport and power deposition. We validate their assumptions and compare the results from these methods to the traditional break-in-slope method as well as to the TORAY ray-tracing code in a set of DIII-D discharges spanning five different confinement modes. We show that the four different inverse methods, novel and established, paint a consistent picture of deposition broadening. Specifically, we show that the measured power deposition profile is between 1.6 and 3.6 times wider than the TORAY profiles. Moreover, we show the considerable consequences that this level of broadening can have for ITER.
24 July 2020 in Plasma Physics and Controlled Fusion
This paper introduces a recent innovation in dealing with non-periodic behavior often referred to as transients in perturbative experiments. These transients can be the result from the unforced response due to the initial condition and other slow trends in the measurement data and are a source of error when performing and interpreting Fourier spectra. Fourier analysis is particularly relevant in system identification used to build feedback controllers and the analysis of various pulsed experiments such as heat pulse propagation studies. The basic idea behind the methodology is that transients are continuous complex-valued smooth functions in the Fourier domain which can be estimated from the Fourier data. Then, these smooth functions can be subtracted from the data such that only periodic components are retained. The merit of the approach is shown in two experimental examples, i.e. heat pulse propagation (core transport analysis) and radiation front movement due to gas puffing in the divertor. The examples show that the quality of the data is significantly improved such that it allows for new interpretation of the results even for non-ideal measurements.
This paper presents a closed-form solution to estimate space-dependent transport parameters of a linear one dimensional diffusion-transport-reaction equation. The infinite dimensional problem is approximated by a finite dimensional model by 1) taking a frequency domain approach, 2) linear parameterization of the unknown parameters, and 3) using a semi-discretization. Assuming full state knowledge, the commonly used output error criterion is rewritten as the equation error criterion such that the problem results in linear least squares. The optimum is then given by a closed-form solution, avoiding computational expensive optimization methods. Functioning of the proposed method is illustrated by means of simulation.
IFLOW is a free, open‐source, and python‐based framework and graphical user interface to visualize and analyze temperature time series, and extract one dimensional thermal velocity, vT, and bulk effective thermal diffusivity, ke. Information of thermal properties of the sediment‐water mixture (bulk) and water allows quantifying the one‐dimensional Darcian flux, q, and seepage velocity, v, from vT. Available software packages were developed to quantify q and ke only based on a specific mathematical model or focused on specific data processing or parameter estimation techniques, and all these steps were lumped together preventing users to identify potential source of errors. iFLOW proposes a novel organizational philosophy with a modular framework that parses the analysis process into three fundamental steps: (a) the mathematical model, (b) signal processing, and (c) parameter estimation. iFLOW houses a suite of models and analysis techniques. This suite can be readily added to and expanded through its modular framework. iFLOW contains a wizard to guide users through the selection process with respect to the three fundamental steps. Users can analyze and visualize intermediate results to identify problematic issues in the time series data and improve data interpretation. Here, we present iFLOW and summarize its performance using a set of one‐dimensional synthetic heat transport simulations.