19 January 2023 in IEEE Transactions on Instrumentation and Measurement
A novel dual-slope resistance to digital converter (RDC) for compensating lead resistance is presented. The RDC uses a dual-slope ADC structure along with three switches and a diode. It completes measurement in one charging-discharging cycle only, hence provides an improvement to existing RDCs based on direct microcontroller interfaces (DMI) where 2 or 3 charging-discharging cycles are required. Moreover, it incorporate the feature of lead resistance compensation in dual-slope RDCs. The scheme works by connecting the resistive sensor to the input terminal of the integrator of the dual-slope ADC. In the charging path (or mode), sensor resistance is present along with lead resistance; and in discharging path, sensor resistance is bypassed, and only lead resistance is there. The difference between the RC time constant during these two modes is used to find the sensor resistance. The diode is used to turn on a switch for bypassing the resistive sensor. The diode voltage drop is not there in the charging and discharging path, which is another novelty. A detailed error analysis is also carried to evaluate the performance of the scheme considering switch resistance, diode voltage drop, voltage mismatch and opamp noises. The scheme works with low-value resistive sensors (≈ 100 Ω), a feature not found in existing dual-slope RDCs. The hardware prototype of the proposed scheme on the breadboard shows a measurement time of 2.09 ms with an average error of ±0.04 % at 100 Ω when lead resistance varied from 20 Ω to 100 Ω. The scheme takes 23.44 % less time for measurement.
1 January 2024 in IEEE Transactions on Instrumentation and Measurement
This study addresses the prevalent issue of self-heating (S-H) error observed in resistive sensors $(R_{X})$ when integrated with electronic circuits to produce output signals. An efficient digitizer circuit is proposed to interface $R_{X}$ and compensate for the S-H error. The circuit employs a dual-slope integrator and a comparator to generate a time sequence output signal. The input current through $R_{X}$ is maintained in the microampere range to minimize the S-H error. Additionally, a T-network is connected to the integrating capacitor to amplify the feedback path’s incoming current. The digitizer is tested for measuring in a wide range of $R_{X} 3.63$ –488.2 $\text{k}\Omega $ , with corresponding power dissipation of 0.273 mW– $2.05 ~\mu \text{W}$ , respectively. The current through $R_{X}$ ranges from 274.59 to $2.05 ~\mu \text{A}$ , and with the current boosting technique (gain ranging from 21.68 to 50.22), it requires a measurement time of 4.73–382.39 ms. This scheme reduces power dissipation by 472.6–1294.94 times compared to existing techniques, signifying a noteworthy improvement. The proposed digitizer produces accurate results with an average error of ±0.56% in experiments where negligible S-H is observed in testing.
15 April 2025 in IEEE Transactions on Instrumentation and Measurement
An efficient interfacing circuit designed for measuring low resistance (RX, less than 1 Ω) and generating a digital output is presented. The digitizer (resistance to digital converter, RDC) circuit utilizes a dual-slope integrator with a T-network in feedback, three single pole single throw (SPDT) switches, and a comparator. Conventional dual-slope integrators face challenges when measuring low RX connected to the inverting terminal, as the high input current causes the op-amp to saturate. Reducing the input voltage to even 0.01 V doesn’t resolve this issue. Alternatively, connecting RX in feedback produces a low output voltage that is susceptible to inherent circuit noise, leading to significant measurement errors. Consequently, no digitizers have been developed to accurately measure RX below 10 Ω so far. The circuit overcomes these limitations by using a T-network which enables the incoming current (IX, 98.09 - 71.75 μA) through RX to amplify the feedback current (IC), hence significantly improving sensitivity which is a novel feature. During charging, lead resistance (RL) with fixed resistance R3 (or RX) is measured, while during discharging, RX and RL are measured together. Subtracting RL ensures accurate RX measurement, independent of RL, in a two-wire configuration. The circuit is experimentally tested for RX in the range of 0.1 - 0.9 Ω (full span) in which the power dissipation ranges from 0.96 - 4.63 nW, while the measurement time varies from 1.29 - 1.51 s. The circuit yields accurate results with an average error of ± 0.68% across the full span of RX.
7 February 2026 in SSRN Electronic Journal
This article introduces a digitizer circuit for interfacing a four-wire configured resistive sensor (RX) with lead resistance compensation (RL) feature. The proposed circuit is minimalistic, utilizing only three core components: (i) an inverting amplifier, (ii) an integrator, and (iii) a comparator. The RX is integrated in the feedback path of the inverting amplifier which generates the required negative potentials for the dual-slope integrator to operate efficiently; highlighting circuit’s first novelty. The circuit operates in two distinct modes: a charging mode and a discharging mode using a couple of switches. These modes produce two separate equations involving RX and RL. By solving these equations, RX is determined independent of RL. This advancement, coupled with the circuit’s compact, and cost-effective design, underscores its second novelty. The circuit is fabricated on PCB, and has been experimentally tested for a Pt100 RTD (Resistance Temperature Detector) sensor, where the temperature changes from 0 °C to 200 °C, causing RX to vary from 100 Ω to 175.84 Ω (full span). The circuit operates on a single input supply and completes the measurement within a single charge-discharge cycle, highlighting its additional features. The sensor current (IXRMS) ranges from 5.87 mA to 6.86 mA, resulting in power dissipation between 3.44 mW and 8.27 mW across the full span. The measurement time varies from 86.21 ms to 62.39 ms, with an average error of ±0.32 %.
15 May 2026 in Measurement
NKNandigama Praveen Kumar