Dóra Keresztes

Dóra Keresztes

Auto-generated profile, based on publicly available information

Dóra Keresztes

University of Pecs, Medical School Medical Skills Education and Innovation Centre, 7624 Pecs, Szigeti út 12, Hungary

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2017 in BMC Anesthesiology
Verified
Journal Article
Open access
PDF file
SRSzilárd Rendeki
Szilárd Rendeki
DKDóra Keresztes
Dóra Keresztes
GWGábor Woth
Gábor Woth
ÁMÁkos Mérei
Ákos Mérei
MRMartin Dr. Rozanovic
Martin Dr. Rozanovic
BNBálint Nagy
Bálint Nagy
Direct laryngoscopy remains the gold standard for endotracheal intubation and is preferred by experienced operators. However, an increasing number of reports currently support videolaryngoscopy, particularly for novice users. The widespread use of videolaryngoscopy may be limited due to financial limitations, especially in low-income countries. Therefore, affordable single-use scopes are now becoming increasingly popular. We sought to compare these new scopes with direct laryngoscopes and the previously tested videolaryngoscopes in mannequins by novices. Fifty medical students were recruited to serve as novice users. Following brief, standardized training, students were asked to execute endotracheal intubation with each of the devices, including the Airtraq®, a custom-made videolaryngoscope, the King Vision®, the Macintosh laryngoscope and the VividTrac®, on an airway trainer (Laerdal Airway Management Trainer®) in normal and difficult airway scenarios. We evaluated the time to and the proportion of successful intubation, the best view of the glottis, esophageal intubation, dental trauma and user satisfaction. We observed no differences in esophageal intubation. However, intubation-related times, the view of the glottis and operator satisfaction were significantly better throughout the study with the commercial videolaryngoscopes. In comparison, the custom-made videolaryngoscope performance proved to be similar to that of the Macintosh laryngoscope. The VividTrac® performance was similar (P > 0.05) or significantly better than that of the King Vision® in both scenarios. Based upon our results, the Airtraq®, King Vision® and VividTrac® were superior to the Macintosh laryngscope in both normal and difficult airway scencarios for novice users. In particular, our study is the first to report that the VividTrac® shows promise for further clinical evaluation.

18 November 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
DKDóra Keresztes
Dóra Keresztes
ÁMÁkos Mérei
Ákos Mérei
MRMartin Rozanovic
Martin Rozanovic
ENEdina Nagy
Edina Nagy
KZKovács-Ábrahám Zoltán
Kovács-Ábrahám Zoltán
GWGábor Woth
Gábor Woth
Early endotracheal intubation improves neurological outcomes in cardiopulmonary resuscitation, although cardiopulmonary resuscitation is initially carried out by personnel with limited experience in a significant proportion of cases. Videolaryngoscopes might decrease the number of attempts and time needed, especially among novices. We sought to compare videolaryngoscopes with direct laryngoscopes in simulated cardiopulmonary resuscitation scenarios. Forty-four medical students were recruited to serve as novice users. Following brief, standardized training, students executed endotracheal intubation with the King Vision®, Macintosh and VividTrac® laryngoscopes, on a cardiopulmonary resuscitation trainer in normal and difficult airway scenarios. We evaluated the time to and proportion of successful intubation, the best view of the glottis, esophageal intubation, dental trauma and user satisfaction. In the normal airway scenario, significantly shorter intubation times were achieved using the King Vision® than the Macintosh laryngoscope. In the difficult airway scenario, we found that the VividTrac® was superior to the King Vision® and Macintosh laryngoscopes in the laryngoscopy time. In both scenarios, we noted no difference in the first-attempt success rate, but the best view of the glottis and dental trauma, esophageal intubation and bougie use were more frequent with the Macintosh laryngoscope than with the videolaryngoscopes. The shortest tube insertion times were achieved using the King Vision® in both scenarios. All providers achieved successful intubation within three attempts, but we found no device superior in any of our scenarios regarding the first-attempt success rate. The King Vision® was superior to the Macintosh laryngoscope in the intubation time in the normal airway scenario and noninferior in the difficult airway scenario for novice users. We noted significantly less esophageal intubation using the videolaryngoscopes than using the Macintosh laryngoscope in both scenarios. Based on our results, the KingVision® might be recommended over the VividTrac® and Macintosh laryngoscopes for further evaluation.

17 September 2024 in Injury
Verified
Journal Article
Closed access
PGPeter Gedei
Peter Gedei
SRSzilard Rendeki
Szilard Rendeki
NWNorbert Wiegand
Norbert Wiegand
Peter MarotiPeter Maroti
Peter Maroti
FMFerenc Jozsef Molnar
Ferenc Jozsef Molnar
JFJozsef Farkas
Jozsef Farkas

13 March 2021 in Research Square
Verified
Preprint
Open access
PDF file
DKDóra Keresztes
Dóra Keresztes
ÁMÁkos Mérei
Ákos Mérei
MRMartin Rozanovic
Martin Rozanovic
ENEdina Nagy
Edina Nagy
KZKovács-Ábrahám Zoltán
Kovács-Ábrahám Zoltán
GWGábor Woth
Gábor Woth
Background: Successful early endotracheal intubation improves neurological outcomes in cardiopulmonary resuscitation. However, endotracheal intubation should not compromise cardiopulmonary resuscitation effectiveness and thus requires experience. The use of videolaryngoscopes might decrease the number of attempts as well as the time needed for intubation, especially among novice users. We sought to compare videolaryngoscopes with direct laryngoscopy in simulated cardiopulmonary resuscitation scenarios in mannequins by novices.Methods: Forty-four medical students were recruited to serve as novice users. Following brief, standardized training, students were asked to execute endotracheal intubation with each of the devices, including the King Vision®, the Macintosh laryngoscope and the VividTrac®, on acardiopulmonary resuscitation trainer (Ambu Man Advanced®) in normal and difficult airway scenarios. We evaluated the time to and the proportion of successful intubation, the best view of the glottis, esophageal intubation, dental trauma and user satisfaction.Results: In the normal airway scenario, significantly shorter intubation times (P < 0.05) were measured by King Vision®than by Macintosh laryngoscope. However, VividTrac® was proven to be similar (P > 0.05) to Macintosh laryngoscope in this regard in the normal airway scenario. In the difficult airway scenarios, we found VividTrac® superior (P < 0.05) to King Vision® and Macintosh laryngoscope regarding laryngoscopy times, but there were no significant differences between devices in intubation times. In both normal and difficult airway cardiopulmonary resuscitation scenarios, we noted no difference (P > 0.05) in first attempt success rates, the best view of the glottis and dental trauma, but esophageal intubation and the use of bougie were more frequent (P < 0.05) withMacintosh laryngoscopethan with videolaryngoscopes. The shortest tube insertion times were related to King Vision® in both scenarios.Conclusion: Based upon our results, King Vision®was superior to Macintosh laryngoscoperegarding intubation time in the normal airway cardiopulmonary resuscitation scenario for novice users. We noted significantly less esophageal intubationwhen using videolaryngoscopes compared to Macintosh laryngoscope in both scenarios; thus,videolaryngoscopes might be recommended for novice users for both cardiopulmonary resuscitation scenarios.