Mingjie Wei

Mingjie Wei

Auto-generated profile, based on publicly available information

Mingjie Wei

Key Laboratory of Power System Intelligent Dispatch and Control Ministry of Education, Shandong University, Jinan, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
MWMingjie Wei
Mingjie Wei
FSFang Shi
Fang Shi
Hengxu ZhangHengxu Zhang
Hengxu Zhang
ZJZongshuai Jin
Zongshuai Jin
VTVladimir Terzija
Vladimir Terzija
HBHailong Bao
Hailong Bao
Grounding arc fault (GAF) happening in the medium-voltage (MV) distribution system may result in great damages to devices and human security. However, difficulties still exist in identifying those faults with higher grounding impedances due to the weaker feature and the varieties when grounded with different surfaces. This paper presents an integrated algorithm to detect the high impedance arc faults (HIAFs) with high-resolution waveform data provided by distribu-tion-level PMUs (D-PMUs) deployed in the system. An im-proved arc model is proposed which can continuously imitate the randomness and intermittence during the ‘unstable arcing period’ of arc faults. The integrated algorithm consists of two branches. Firstly, the variations of HIAFs during unstable arcing period is identified with the unified harmonic energy and global randomness index, which can unify the scale of harmonic content in different fault situations and enlarge the disparities from non-fault conditions. Then, the waveform distortions of HIAFs during the stable arcing period are identified with discrete wavelet transform (DWT) to extract the detailed distribution characteristics. The reliability and security of the proposed algorithm is verified with numerical simulations and field tests in a 10kV distribution system.

27 July 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
MWMingjie Wei
Mingjie Wei
WLWeisheng Liu
Weisheng Liu
Hengxu ZhangHengxu Zhang
Hengxu Zhang
FSFang Shi
Fang Shi
WCWeijiang Chen
Weijiang Chen
Detection of the high impedance fault (HIF) in distribution systems is significant for power utilization safety. However, many HIFs are challenging to be identified due to low currents and diverse characteristics. Particularly, the slight nonlinearity during weak arcing processes, the distortion offset caused by various heat dissipations, and the interference of noises could lead to malfunctions of traditional algorithms. This paper proposes a distortion-based algorithm to improve the reliability of HIF detection. Firstly, the challenges brought by the diversity of HIF characteristics are illustrated with field experiments in a 10kV real-world system. HIFs are classified into five types according to their various distortions. Secondly, an interval slope is defined to describe waveform distortions. The interval slope is extracted by linear least square filtering (LLSF) and Grubbs-criterion-based robust local regression smoothing (Grubbs-RLRS), so that distortions under different fault conditions can be uniformly described. Thirdly, an algorithm is proposed to judge the features presented by the interval slope, and distinguish from non-fault conditions. Finally, the reliability and security of the proposed algorithm are thoroughly analyzed with real-world HIFs and the simulated HIFs in IEEE 34-bus and IEEE 123-bus systems. Improvements of the proposed algorithm are shown by comparing with other algorithms.

18 March 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
MWMingjie Wei
Mingjie Wei
WLWeisheng Liu
Weisheng Liu
FSFang Shi
Fang Shi
Hengxu ZhangHengxu Zhang
Hengxu Zhang
ZJZongshuai Jin
Zongshuai Jin
WCWeijiang Chen
Weijiang Chen
The accurate modelling of the arc is significant for the researches on the high impedance arcing fault (HIAF), which performs sig-nificant variations of nonlinearity under different fault conditions. The diversity of the waveform distortions during HIAFs is rarely investigated previously. This paper proposes a black-box HIAF model to simulate the nonlinear current distortions with im-proved controllability and higher accuracy. Firstly, with field HIAF faults experimented in a 10kV distribution network, three major characteristics varying in the distortions of the fault cur-rent are summarized and illustrated, including the offset, extent, and duration. Secondly, a distortion-controllable (DIST-C) HIAF model is proposed based on the heat balance equation of the arc after reasonable assumptions and transformations. The three characteristics of distortions can be independently and directly controlled. Then, the implementation of the DIST-C model in PSCAD is detailedly illustrated. An automatic parameter deter-mination method using particle swarm optimization in a Py-thon-PSCAD-MATLAB co-simulation platform is presented. Finally, the controllability and accuracy of the proposed model are verified by comparing it with the other existing typical black-box models.

18 August 2022 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
MWMingjie Wei
Mingjie Wei
FSFang Shi
Fang Shi
Hengxu ZhangHengxu Zhang
Hengxu Zhang
WCWeijiang Chen
Weijiang Chen
The increasing integration of distributed energy resources (DERs) into the distribution system has caused interference with the signals stimulated by high impedance faults (HIFs). Many existing HIF detection or location methods that are only based on the superficial nonlinearity features of signals rather than the deep laws, will become invalid. This paper proposes a detection and location scheme for HIFs by theoretically analyzing the relationships between signals and systems. By establishing the equivalent circuit of a resonant distribution system, an online method to calculate the kernel system parameters is proposed, based on which an adaptive criterion for HIF detection is provided. In this way, the ability to detect HIF is adequately exploited and independent of DER influences. The method is able to detect HIF over 8.5 $\text{k}{\Omega }$ under common operating conditions. Furthermore, the nonlinearity of HIF is analyzed by deriving laws about how wideband signals distribute in the system. The $3^{\mathrm{ rd}}$ harmonic component of zero-sequence signals is proved to be superior in HIF location in terms of signal content and discrimination, which is also demonstrated to be valid under the influence of DER harmonic injection. On this basis, a HIF location method utilizing the $3^{\mathrm{ rd}}$ harmonic zero-sequence signals is proposed. The effectiveness of the method and its robustness to the DER interference are validated by simulated and field HIFs in 10kV systems.

21 April 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
MWMingjie Wei
Mingjie Wei
Hengxu ZhangHengxu Zhang
Hengxu Zhang
FSFang Shi
Fang Shi
WCWeijiang Chen
Weijiang Chen
VTVladimir Terzija
Vladimir Terzija
Feeder identification is indispensable for distribution networks to locate faults at a specific feeder, especially when measuring devices are insufficient to locate faults more precisely. For the high impedance fault (HIF), the feeder identification is much more challengeable and related approaches are still in the early stage. This paper thoroughly reveals the nonlinearity characteristics of different feeders when a HIF happens at a three-wire system that is with the resonant grounded neutral (RGN). Firstly, the diversity of nonlinearity existing in HIFs is explained from the perspective of energy. Then, the nonlinearity of zero-sequence current that differs between healthy and faulty feeders are deduced theoretically. Effects of the detuning index of Petersen coil, the damping ratio of system, and the length of feeder are all considered. Afterward, these theoretical conclusions are verified by the HIF cases experimented in a real 10kV system. Finally, after indicating the problems of a classic phase-relationship-based algorithm, we suggest an improved method based on the phase differences between the harmonic currents of different feeders. The effectiveness of the method has been verified.

14 May 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
MWMingjie Wei
Mingjie Wei
FSFang Shi
Fang Shi
Hengxu ZhangHengxu Zhang
Hengxu Zhang
FYFan Yang
Fan Yang
WCWeijiang Chen
Weijiang Chen
Numerical modeling of the high impedance arc fault (HIAF) is essential to supplementing the deficiency of real-world fault cases and extending the fault scenarios. Setting parameters of the model correctly is the basis to reproduce practical fault waveforms. According to the literature, the parameters of HIAF models are mostly determined manually and subjectively. The existing automatic methods of parameter determination are mostly used in the modeling of other types of arcs (such as DC arcs and circuit breaker arcs), which do not consider the connections with power networks. It will be time-consuming if directly applying these methods to the HIAF model with the connection of a power network. In this paper, after introducing the unique requirements in simulating the nonlinearity of HIAFs, a high-efficiency parameter determination method is proposed for HIAF models. The method is realized by interfacing the optimizer programmed in Python with the HIAF model and power network established in PSCAD. In this process, a combination of pulse controllers is designed and certain configurations are proposed, so that the parameter determination procedure can be significantly simplified. Case studies show that, by combining the proposed high-efficiency method with our previously proposed DIST-C HIAF model, fitting accuracy and efficiency can be guaranteed at the same time. The time for parameter determination of a HIAF model is only within minutes, decreasing hundreds of times and independent of the length of desired waveforms.