27 July 2020 in IEEE Transactions on Power Delivery
Detection of the high impedance fault (HIF) in distribution systems is significant for power utilization safety. However, many HIFs are challenging to be identified due to low currents and diverse characteristics. Particularly, the slight nonlinearity during weak arcing processes, the distortion offset caused by various heat dissipations, and the interference of noises could lead to malfunctions of traditional algorithms. This paper proposes a distortion-based algorithm to improve the reliability of HIF detection. Firstly, the challenges brought by the diversity of HIF characteristics are illustrated with field experiments in a 10kV real-world system. HIFs are classified into five types according to their various distortions. Secondly, an interval slope is defined to describe waveform distortions. The interval slope is extracted by linear least square filtering (LLSF) and Grubbs-criterion-based robust local regression smoothing (Grubbs-RLRS), so that distortions under different fault conditions can be uniformly described. Thirdly, an algorithm is proposed to judge the features presented by the interval slope, and distinguish from non-fault conditions. Finally, the reliability and security of the proposed algorithm are thoroughly analyzed with real-world HIFs and the simulated HIFs in IEEE 34-bus and IEEE 123-bus systems. Improvements of the proposed algorithm are shown by comparing with other algorithms.
18 March 2020 in IEEE Transactions on Power Delivery
The accurate modelling of the arc is significant for the researches on the high impedance arcing fault (HIAF), which performs sig-nificant variations of nonlinearity under different fault conditions. The diversity of the waveform distortions during HIAFs is rarely investigated previously. This paper proposes a black-box HIAF model to simulate the nonlinear current distortions with im-proved controllability and higher accuracy. Firstly, with field HIAF faults experimented in a 10kV distribution network, three major characteristics varying in the distortions of the fault cur-rent are summarized and illustrated, including the offset, extent, and duration. Secondly, a distortion-controllable (DIST-C) HIAF model is proposed based on the heat balance equation of the arc after reasonable assumptions and transformations. The three characteristics of distortions can be independently and directly controlled. Then, the implementation of the DIST-C model in PSCAD is detailedly illustrated. An automatic parameter deter-mination method using particle swarm optimization in a Py-thon-PSCAD-MATLAB co-simulation platform is presented. Finally, the controllability and accuracy of the proposed model are verified by comparing it with the other existing typical black-box models.
18 August 2022 in IEEE Transactions on Smart Grid
The increasing integration of distributed energy resources (DERs) into the distribution system has caused interference with the signals stimulated by high impedance faults (HIFs). Many existing HIF detection or location methods that are only based on the superficial nonlinearity features of signals rather than the deep laws, will become invalid. This paper proposes a detection and location scheme for HIFs by theoretically analyzing the relationships between signals and systems. By establishing the equivalent circuit of a resonant distribution system, an online method to calculate the kernel system parameters is proposed, based on which an adaptive criterion for HIF detection is provided. In this way, the ability to detect HIF is adequately exploited and independent of DER influences. The method is able to detect HIF over 8.5 $\text{k}{\Omega }$ under common operating conditions. Furthermore, the nonlinearity of HIF is analyzed by deriving laws about how wideband signals distribute in the system. The $3^{\mathrm{ rd}}$ harmonic component of zero-sequence signals is proved to be superior in HIF location in terms of signal content and discrimination, which is also demonstrated to be valid under the influence of DER harmonic injection. On this basis, a HIF location method utilizing the $3^{\mathrm{ rd}}$ harmonic zero-sequence signals is proposed. The effectiveness of the method and its robustness to the DER interference are validated by simulated and field HIFs in 10kV systems.
21 April 2021 in IEEE Transactions on Power Delivery
Feeder identification is indispensable for distribution networks to locate faults at a specific feeder, especially when measuring devices are insufficient to locate faults more precisely. For the high impedance fault (HIF), the feeder identification is much more challengeable and related approaches are still in the early stage. This paper thoroughly reveals the nonlinearity characteristics of different feeders when a HIF happens at a three-wire system that is with the resonant grounded neutral (RGN). Firstly, the diversity of nonlinearity existing in HIFs is explained from the perspective of energy. Then, the nonlinearity of zero-sequence current that differs between healthy and faulty feeders are deduced theoretically. Effects of the detuning index of Petersen coil, the damping ratio of system, and the length of feeder are all considered. Afterward, these theoretical conclusions are verified by the HIF cases experimented in a real 10kV system. Finally, after indicating the problems of a classic phase-relationship-based algorithm, we suggest an improved method based on the phase differences between the harmonic currents of different feeders. The effectiveness of the method has been verified.
16 May 2022 in IEEE Transactions on Magnetics
When an external short circuit occurs, the axial electromagnetic force increases dozens of times. Under the effect of the axial short-circuit electromagnetic force, the transformer windings vibrate violently. The spatial distribution of the disks is constantly changing during vibration, which can change the temporal and spatial distributions of the leakage magnetic field and the axial electromagnetic force. This process is called the strong coupling phenomenon of the structural field and the leakage magnetic field. In this article, a strong coupled magnetic-structural model is proposed by using the analysis method. The strong coupling equations, where the independent variables are the axial position of the disks, are obtained. The vibration process with strong coupling phenomenon considered can be obtained. The accuracy of the strong coupling model is verified by the iterative method. By comparing the results calculated by the strong coupling model with those calculated by the weak coupling model, the influence of the strong coupling phenomenon on the vibration process is obtained. Due to the influence of the strong coupling phenomenon, the winding vibration intensity increases and the maximum displacement of the disks can be doubled, which implied that the strong coupling phenomenon cannot be ignored when investigating the short-circuit strength of power transformers.
30 April 2013 in IEEE Transactions on Power Delivery
A capacitor sensor with a high-voltage electrode inside the GIS tank has the best bandwidth among the sensors developed to measure the very fast transient overvoltage (VFTO). However, the low-voltage arm of the current measurement system is usually a handmade film capacitor which has disadvantages of unassigned capacitance value, temperature effect, and short lifespan. With a novel lower voltage arm based on surface-mounted devices, a wide-bandwidth, stable, and easy maintenance measuring system is proposed in this paper. It is found that the slight inherent inductance in the ground trace of the printed-circuit board can induce unexpected oscillations, which are demonstrated with theoretical analysis and experimental study. With the reforming of the printed-circuit board layout, the oscillation is reduced and 200-MHz high-frequency cutoff frequency is achieved. The environment experiment shows that the temperature effect on the developed sensor is much smaller than that on the conventional sensor. The VFTO generated by disconnector operation in 1100-kV GIS is measured by the developed system and a conventional broadband capacitor sensor. The contrastive results prove that the characteristic of the measuring system can meet the requirement of VFTO measurements. Thousands of measurements on ultra-high voltage GIS indicate that the developed measuring system is stable, and characteristics of the VFTO are gained.