Christopher I. McHugh

Christopher I. McHugh

Auto-generated profile, based on publicly available information

Christopher I. McHugh

Eaton-Peabody Laboratories, Department of Otolaryngology-Head and Neck Surgery, Mass Eye and Ear, Boston, MA, USA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2024 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
AYAaron J Yeiser
Aaron J Yeiser
EWEmma F Wawrzynek
Emma F Wawrzynek
JZJohn Z Zhang
John Z Zhang
LGLukas Graf
Lukas Graf
CMChristopher I McHugh
Christopher I McHugh
HNHideko Heidi Nakajima
Hideko Heidi Nakajima
Objective. We present the ‘UmboMic,’ a prototype piezoelectric cantilever microphone designed for future use with totally-implantable cochlear implants. Methods. The UmboMic sensor is made from polyvinylidene difluoride (PVDF) because of its low Young’s modulus and biocompatibility. The sensor is designed to fit in the middle ear and measure the motion of the underside of the eardrum at the umbo. To maximize its performance, we developed a low noise charge amplifier in tandem with the UmboMic sensor. This paper presents the performance of the UmboMic sensor and amplifier in fresh cadaveric human temporal bones. Results. When tested in human temporal bones, the UmboMic apparatus achieves an equivalent input noise of 32.3 dB SPL over the frequency range 100 Hz–7 kHz, good linearity, and a flat frequency response to within 10 dB from about 100 Hz–6 kHz. Conclusion. These results demonstrate the feasibility of a PVDF-based microphone when paired with a low-noise amplifier. The reported UmboMic apparatus is comparable in performance to a conventional hearing aid microphone. Significance. The proof-of-concept UmboMic apparatus is a promising step towards creating a totally-implantable cochlear implant. A completely internal system would enhance the quality of life of cochlear implant users.

3 October 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
BCBenjamin G. Cary
Benjamin G. Cary
JZJohn Z. Zhang
John Z. Zhang
CMChristopher I. McHugh
Christopher I. McHugh
IKIoannis Kymissis
Ioannis Kymissis
EOElizabeth S. Olson
Elizabeth S. Olson
JLJeffrey H. Lang
Jeffrey H. Lang
This article presents an implantable microphone for sensing the displacement of the umbo, the end of the malleus where it attaches to the center tip of the cone-shaped tympanic membrane. The sensor comprises a piezoelectric polyvinylidene fluoride (PVDF) film with copper–nickel electrodes suspended across a brass cylinder. The cylinder is oriented so that the umbo pushes on the film center, causing a static and acoustically driven dynamic film displacement. An amplifier filters the resulting piezoelectric charge to produce an output signal. The sensor enables the full implantation of assistive hearing devices, which can restore hearing without inhibiting the user’s lifestyle, while enabling better sound localization in noisy environments.

15 August 2022 in The Laryngoscope
Verified
Journal Article
Closed access
YSYohan Song
Yohan Song
CMChristopher McHugh
Christopher McHugh
JTJennifer Tirino
Jennifer Tirino
THTessa Hadlock
Tessa Hadlock
FSFelipe Santos
Felipe Santos

9 January 2022
Verified
Conference Paper
Closed access
JZJohn Z. Zhang
John Z. Zhang
BCBenjamin G. Cary
Benjamin G. Cary
AYAaron Yeiser
Aaron Yeiser
CMChristopher I. McHugh
Christopher I. McHugh
HNHideko Heidi Nakajima
Hideko Heidi Nakajima
EOElizabeth S. Olson
Elizabeth S. Olson
This paper reports the analysis, design, and experimental characterization of a piezoelectric intracochlear hydrophone and amplifier system to function as an implantable microphone for totally-implantable cochlear implants. We derived an analytical model for the piezoelectric hydrophone, which we validated with finite-element modeling (FEM) and experiments. We developed a circuit and noise model of the amplifier, which we verified through measurements. We proposed a PVDF-TrFE intracochlear hydrophone with a charge amplifier co-designed for maximum performance: sensitivity, bandwidth, and output noise. To characterize the hydrophone and amplifier, we used a vibrating water column calibration method. We determined the shielding and experimental design considerations necessary to collect reliable data. The system presented here achieved an overall sensitivity of 20.6 mV/Pa at 3 kHz, a bandwidth of 470 Hz to 16 kHz, and a root-mean-square (RMS) output noise of 17.6 mV dominated by the amplifier. Our approach for an implantable microphone proves to be a promising candidate for cochlear implants.

16 September 2025 in bioRxiv
Verified
Preprint
Open access
PSPaul Secchia
Paul Secchia
CMChristopher I McHugh
Christopher I McHugh
NCNam Hyun Cho
Nam Hyun Cho
JOJennifer T O'MAlley
Jennifer T O'MAlley
MZMengYu Zhu
MengYu Zhu
HNHideko Heidi Nakajima
Hideko Heidi Nakajima
The human cochlea is encased within the otic capsule, the densest bone in the body, posing significant challenges for anatomical imaging of cochlear structures. Because of difficult access and fragility of cochlear structures, our understanding of intracochlear anatomy has historically relied on postmortem histology. We thus have a limited understanding of human cochlear anatomy in its native, unfixed state. Clinical diagnostics for hearing loss, such as audiometry and otoacoustic emissions, offer functional assessments but fail to elucidate the often diverse underlying structural pathologies with any degree of precision. To address the critical need for assessing the human cochlear anatomy and associated pathologies without the risk of traumatizing cochlear structures, we imaged fresh cochleae in situ soon after death through the intact round window membrane with Optical Coherence Tomography (OCT) without inserting instruments inside or opening the cochlea. Micron-resolution OCT cross-sectional images of the human intracochlear structures were acquired and compared with corresponding histology systematically to aid in the identification of fine structural features and possible pathologies. With OCT imaging, we observed varied anatomy of the organ of Corti, and developed a cochlear ″integrity″ rating system to differentiate healthy appearing cochleae from various pathological states. These results demonstrate the capability of OCT to non-traumatically visualize cochlear integrity, highlighting its potential as a diagnostic tool. This work shows promise in translating the ability to determine the likelihood of existing or lack of hair cells and supporting cells in live patients, which would enable appropriate targeted treatments.

24 October 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
PSPaul Secchia
Paul Secchia
CMChristopher I. McHugh
Christopher I. McHugh
NCNam Hyun Cho
Nam Hyun Cho
AZAleksandrs Zosuls
Aleksandrs Zosuls
ATAndrew Tubelli
Andrew Tubelli
HNHideko Heidi Nakajima
Hideko Heidi Nakajima
Optical coherence tomography (OCT) was used to image and measure the passive sound-driven displacements of cochlear structures in situ through the intact round window membrane of fresh human cadaveric specimens at 12 to 30 hours postmortem. We find that the anatomical integrity of the organ of Corti (OoC) affects cochlear structural motion. OoC with high integrity (erect with supporting cells) have small osseous spiral lamina (OSL) motion. Conversely, OoC with low integrity (flattened without supporting cells) have large OSL motion. For the ratio of motion between the basilar membrane (BM) and OSL (BM/OSL), OoC with high integrity has large BM/OSL motion while a cochlear partition without OoC has small BM/OSL motion. Furthermore, the high-integrity OoC has reticular lamina surface motion that is lower than the BM, whereas low-integrity OoC has similar reticular lamina and BM motion. This relationship between OoC anatomical integrity and cochlear structural motion will have consequential effects on sound transduction. Statement of Significance: Acoustic vibrations are transformed into neural signals within the cochlea, the mammalian organ of hearing. Our understanding of cochlear mechanics has been limited to laboratory animals, whose cochleae have significant anatomical and functional differences from humans. To bridge this gap, we imaged and recorded the motion of cochlear structures in intact human cadaveric cochlear specimens without disturbing the interior of the cochlea. We determined how the anatomical integrity of the Organ of Corti (that contains structures for sound transduction) affects cochlear structural motion.