Lukas Graf

Dr. Lukas Graf

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2024 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
AYAaron J Yeiser
Aaron J Yeiser
EWEmma F Wawrzynek
Emma F Wawrzynek
JZJohn Z Zhang
John Z Zhang
LGLukas Graf
Lukas Graf
CMChristopher I McHugh
Christopher I McHugh
HNHideko Heidi Nakajima
Hideko Heidi Nakajima
Objective. We present the ‘UmboMic,’ a prototype piezoelectric cantilever microphone designed for future use with totally-implantable cochlear implants. Methods. The UmboMic sensor is made from polyvinylidene difluoride (PVDF) because of its low Young’s modulus and biocompatibility. The sensor is designed to fit in the middle ear and measure the motion of the underside of the eardrum at the umbo. To maximize its performance, we developed a low noise charge amplifier in tandem with the UmboMic sensor. This paper presents the performance of the UmboMic sensor and amplifier in fresh cadaveric human temporal bones. Results. When tested in human temporal bones, the UmboMic apparatus achieves an equivalent input noise of 32.3 dB SPL over the frequency range 100 Hz–7 kHz, good linearity, and a flat frequency response to within 10 dB from about 100 Hz–6 kHz. Conclusion. These results demonstrate the feasibility of a PVDF-based microphone when paired with a low-noise amplifier. The reported UmboMic apparatus is comparable in performance to a conventional hearing aid microphone. Significance. The proof-of-concept UmboMic apparatus is a promising step towards creating a totally-implantable cochlear implant. A completely internal system would enhance the quality of life of cochlear implant users.

1 February 2022 in International Journal of Audiology
Verified
Journal Article
Open access
LGLukas Graf
Lukas Graf
JLJonas Lochner
Jonas Lochner
HMHamidreza Mojallal
Hamidreza Mojallal
AAAndreas Arnold
Andreas Arnold
FHFlurin Honegger
Flurin Honegger
CSChristof Stieger
Christof Stieger
The Vibrant Soundbridge (VSB) is one of the most widely used implantable hearing devices. It consists of a vibrating floating mass transducer (FMT) that is connected to a middle ear structure. The ...

13 January 2023 in Hearing Research
Verified
Journal Article
Open access
LGLukas Graf
Lukas Graf
AAAndreas Arnold
Andreas Arnold
SBSandra Blache
Sandra Blache
FHFlurin Honegger
Flurin Honegger
MMMagdalena Müller-Gerbl
Magdalena Müller-Gerbl
CSChristof Stieger
Christof Stieger
Conserved specimens do not decay and therefore permit long-term experiments thereby overcoming limited access to fresh (frozen) temporal bones for studies on middle ear mechanics. We used a Thiel conservation method which is mainly based on a watery solution of salts. In contrast to pure Formalin, Thiel conservation aims to preserve the mechanical proprieties of human tissue. The aim of this study is to examine the effect of Thiel conservation on bone conduction in the same specimen before and after conservation. Nine ears of five defrosted whole heads were stimulated with a direct, electrically driven, bone anchored hearing system (Baha, Baha SuperPower). The motion produced by bone conduction stimulation was measured with a single point laser Doppler vibrometer (LDV) at the promontory, the ossicular chain, and the round window through a posterior tympanotomy. After the initial experiments, the entire whole heads were placed in Thiel solution. In order to enable direct comparison between fresh frozen and Thiel specimens, our Thiel conservation did not include intravascular and intrathecal perfusion. The measurements were repeated 3 and 12 months later. To determine the effect of freezing, defrosting, and embalming on the whole heads, CT scans were performed at different stages of the experimental procedure. Additionally, three extracted temporal bones were stimulated a Baha, motion of the promontory measured by LDV and embalmed in Thiel solution to investigate the direct impact of Thiel solution on the bone. The averaged magnitude of motion on the promontory increased in whole head specimens by a mean of 10.3 dB after 3 months of Thiel embalming and stayed stable after 12 months. A similar effect was observed for motion at the tympanic membrane (+7.2 dB), the stapes (+9.5 dB), and the round window (+4.0 dB). In contrast to the whole head specimens, the motion of the extracted temporal bones did not change after 3 months of Thiel embalming (-0.04 dB in average). CT scans of the whole heads after conservation showed a notable brain volume loss mostly >50% as well as a remarkable change in the consistency and structure of the brain. Partial changes could already be observed before the Thiel embalming but after 1-2 days of defrosting. In an additional experiment, a substitution of brain mass and weight by Thiel fluid did not lead to new deterioration in sound transmission. In contrast, a frozen (non-defrosted) whole head showed a distinctively reduced magnitude of promontory motion before defrosting. For our setup, the vibration of the ear due to bone conduction in the same whole head specimens significantly increased after Thiel conservation. Such an increase was not observed in extracted temporal bone specimens. Due to brain changes in the CT scans, we investigated the consequences of the brain volume changes and structure loss on the frozen brain before defrosting. The loss of brain volume alone could not explain the increase of ear vibrations, as we did not observe a difference when the volume was replaced with Thiel fluid. However, freezing and defrosting of the entire brain seems to have a major influence. Beside the destructive effect of freezing on the brain, the modified conservation method without perfusion changed the brain structure. In conclusion, bone conduction in whole heads depends on the physical condition of the brain, rather than on the conservation.

9 December 2024 in International Journal of Audiology
Verified
Journal Article
Open access
LGLukas Graf
Lukas Graf
JLJonas Lochner
Jonas Lochner
HMHamidreza Mojallal
Hamidreza Mojallal
AAAndreas Arnold
Andreas Arnold
FHFlurin Honegger
Flurin Honegger
CSChristof Stieger
Christof Stieger
The "floating mass transducer" (FMT) of the Vibrant Soundbridge was initially attached to the long process of the incus (LP). In patients missing an incus, coupling to the stapes head using the Vibroplasty CliP-coupler is used. Its main limitation is the height, leading to potential contact with the tympanic membrane. The new stapes head (SH)-coupler reduces the functional height but tilts the stimulation angle by 30°. We investigated the SH-coupler's magnitude and sound transmission quality compared to the LP-coupler. Laser Doppler vibrometry was used on 10 cadaveric human temporal bones. Measurements of the stapes and round window motion were taken for electrical (FMT-) stimulation during application of both couplers. At the round window, the SH-coupler showed a significantly higher gain magnitude than the LP-coupler (+ 13.4 dB over 1023-3577Hz). At low frequencies (382-500Hz), the SH-coupler gain was significantly lower (-9.9 dB). Total harmonic distortions >10% at 100 dB HLeq were recorded in 3.4% of the SH- and 7.4% of the LP-couplers above 500 Hz. The SH-coupler's performance exceeds the LP-coupler in middle and high frequencies and is comparable to and a good alternative to the CliP-coupler, dependent on the individual anatomy.

22 December 2023 in arXiv
Verified
Preprint
Open access
PDF file
AYAaron J. Yeiser
Aaron J. Yeiser
EWEmma F. Wawrzynek
Emma F. Wawrzynek
JZJohn Z. Zhang
John Z. Zhang
LGLukas Graf
Lukas Graf
CMChristopher I. McHugh
Christopher I. McHugh
HNHideko Heidi Nakajima
Hideko Heidi Nakajima
Objective: We present the "UmboMic," a prototype piezoelectric cantilever microphone designed for future use with totally-implantable cochlear implants. Methods: The UmboMic sensor is made from polyvinylidene difluoride (PVDF) because of its low Young's modulus and biocompatibility. The sensor is designed to fit in the middle ear and measure the motion of the underside of the eardrum at the umbo. To maximize its performance, we developed a low noise charge amplifier in tandem with the UmboMic sensor. This paper presents the performance of the UmboMic sensor and amplifier in fresh cadaveric human temporal bones. Results: When tested in human temporal bones, the UmboMic apparatus achieves an equivalent input noise of 32.3 dB SPL over the frequency range 100 Hz to 7 kHz, good linearity, and a flat frequency response to within 10 dB from about 100 Hz to 6 kHz. Conclusion: These results demonstrate the feasibility of a PVDF-based microphone when paired with a low-noise amplifier. The reported UmboMic apparatus is comparable in performance to a conventional hearing aid microphone. Significance: The proof-of-concept UmboMic apparatus is a promising step towards creating a totally-implantable cochlear implant. A completely internal system would enhance the quality of life of cochlear implant users.

6 January 2026 in Hearing Research
Verified
Journal Article
Open access
LGLukas Graf
Lukas Graf
DSDavid Stauske
David Stauske
MGMohammad Ghoncheh
Mohammad Ghoncheh
AAAndreas Arnold
Andreas Arnold
HMHamidreza Mojallal
Hamidreza Mojallal
HMHannes Maier
Hannes Maier
Various couplers exist for the Vibrant Soundbridge implant to connect the actuator to a middle ear structure. While the surgical indication mainly distinguishes between purely sensorineural hearing loss and mixed hearing loss, and audiological indication ranges are designed accordingly, we believe that the biomechanical distinction between forward and reverse cochlear stimulation is more meaningful. To evaluate this, we apply all common couplers in temporal bone experiments and correct the measurements for adequate comparability. The study was conducted at two research labs, each with n = 10 cadaveric temporal bones. Laser Doppler velocity measurements on the stapes were used for direct comparison between the coupling methods. Therefore, reverse cochlear stimulation requires a correction factor due to pressure loss through a third window. This was calculated by measuring intracochlear pressure differences in the same specimens. Compared to the stapes LDV measurement, reverse stimulations require a correction factor that continuously decreases in the high frequency range: approximately +22.4 dB between 125-250 Hz, +7.9 dB between 300-800 Hz, and +4.8 dB above 1000 Hz. Taking this into account, there is still a considerable difference between the forward and reverse stimulation methods of 15-22 dB in the frequency range 2000 Hz to the favor of forward stimulation. Forward couplings, including direct stapes coupling, are mechanically superior to reverse stimulation. The stapes head coupler performs 7-25 dB better than the round window coupler and similar or even superior to incus couplers.