Fong Chi Ho

Fong Chi Ho

Auto-generated profile, based on publicly available information

Fong Chi Ho

Center for Virtual Imaging Trials, Department of Electrical Engineering, Duke University Health System, Durham, USA

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2026 in Journal of Imaging Informatics in Medicine
Verified
Journal Article
Closed access
PDF file
DFD. Milo Fryling
D. Milo Fryling
LVLiesbeth Vancoillie
Liesbeth Vancoillie
FHFong Chi Ho
Fong Chi Ho
CMCindy McCabe
Cindy McCabe
NFNicholas Felice
Nicholas Felice
ESEhsan Samei
Ehsan Samei

1 January 2026 in Journal of Medical Imaging
Verified
Journal Article
Closed access
FHFong Chi Ho
Fong Chi Ho
WSWilliam Paul Segars
William Paul Segars
ESEhsan Samei
Ehsan Samei
EAEhsan Abadi
Ehsan Abadi
PurposeAccurate airway measurement is critical for bronchitis quantification with computed tomography (CT), yet optimal protocols and the added value of photon-counting CT (PCCT) over energy-integrating CT (EICT) for reducing bias remain unclear. We quantified biomarker accuracy across modalities and protocols and assessed strategies to reduce bias.ApproachA virtual imaging trial with 20 bronchitis anthropomorphic models was scanned using a validated simulator for two systems (EICT: SOMATOM Flash; PCCT: NAEOTOM Alpha) at 6.3 and 12.6 mGy. Reconstructions varied algorithm, kernel sharpness, slice thickness, and pixel size. Pi10 (square-root wall thickness at 10-mm perimeter) and WA% (wall-area percentage) were compared against ground-truth airway dimensions obtained from the 0.1-mm-precision anatomical models prior to CT simulation. External validation used clinical PCCT (n=22) and EICT (n=80).ResultsSimulated airway dimensions agreed with pathological references (R=0.89−0.93). PCCT had lower errors than EICT across segmented generations (p<0.05). Under optimal parameters, PCCT improved Pi10 and WA% accuracy by 26.3% and 64.9%. Across the tested PCCT and EICT imaging protocols, improvements were associated with sharper kernels (25.8% Pi10, 33.0% WA%), thinner slices (23.9% Pi10, 49.8% WA%), smaller pixels (17.0% Pi10, 23.1% WA%), and higher dose (≤3.9%). Clinically, PCCT achieved higher maximum airway generation (8.8±0.5 versus 6.0±1.1) and lower variability, mirroring trends in virtual results.ConclusionsPCCT improves the accuracy and consistency of airway biomarker quantification relative to EICT, particularly with optimized protocols. The validated virtual platform enables modality-bias assessment and protocol optimization for accurate, reproducible bronchitis measurements.