When a high-speed train approaches an insulated split-phase section embedded between neighbouring power supply arms carrying powers with different phases, the vehicle-mounted vacuum circuit breaker (VCB) needs to be switched off to avoid short-circuit fault during the phase-changing procedure. At the moment of switching the VCB contacts, the arc is triggered easily, accompanying with overvoltage impulse. As the core of the whole system, the traction transformer frequently suffers the invasion of the overvoltage impulse, which possibly causes partial discharge or breakdown accidents. To evaluate the impact of overvoltage on the transformer, it is essential to observe the overvoltage distribution at different positions in the transformer. As an equivalent circuit model of the traction transformer involving the spatially distributed capacitance is built based on the improved capacitor network methodology (ICNM), the partial discharge risk in the transformer has been assessed. Ultimately, the multi-physics coupling models based on the finite element method have been launched for observe the specific distribution of the multiphysics field for verifying the validity of equivalent circuit model based on ICNM. These works lay the theoretical foundation for guiding the design of insulation and the thermal dissipation settings of the traction transformer, considering the threat brought from impulse.
23 August 2023 in IEEE Transactions on Vehicular Technology
As a unique reflux path for trains, the ‘train-rail’ mobile grounding system has the double functions – the traction power feedback and the transmission of train's communication signal. With the constant increment of operational velocity and traction power for high-speed railway, the coupling relationship existing in the ‘train-rail’ mobile coupling grounding system becomes complicated, when the train's wheels roll over the insulated joint. It may result in the frequent occurrence of rolling arc and the ablation of rail ends and insulated joints, which might lead to the series connection of the rail circuit or even trigger the misjudgment of operational control system. As the impedances existing in the grounding system vary transiently when the relative distance between the train and the fixed terrestrial grounding installations changes, the dynamic coupling mechanism between the transiently-varying topology of reflux path and the distribution of reflux at each grounding wheel tends to be analyzed. Depending on the built ‘catenary-train-rail’ dynamic coupling grounding reflux model, the correlation between the ‘train-rail’ mobile grounding reflux and the evolutionary process of rolling arc is explored. In order to reduce the risk of ‘wheel-rail’ arcing phenomenon, a novel method of automatically controlling insulated joint is proposed herein, as its feasibility is verified via the comparison with the original type of the insulated joint.
10 April 2024 in IEEE Transactions on Vehicular Technology
As the unique power-discharging channel for high-speed trains, the ‘train-rail’ mobile coupling grounding system plays a vital role in sending the traction power back to the terrestrial substations, through the electrical contact between the rotating wheel and the steel rail. The whole system is composed of two kinds of grounding modes: working grounding is in charge of draining the traction power into the rail track; the protective grounding provides the reference grounding potential for the vehicle-mounted equipment. Different from the fixed terrestrial grounding technique normally implemented in power system, when the relative motion occurs between the train and the rail, both the ‘catenary-to-train’ and ‘train-to-ground’ impedances vary transiently, which may lead to the current flowing through each grounding wheel varying unpredictably. Herein, the ‘catenary-train-rail’ mobile coupling grounding model was built based on the equivalent circuit modeling technique for evaluating the transiently-varying tendency of the grounding impedances and currents flowing through each grounding wheel. To cope with different operational conditions, the adjustable grounding impedance methodology is firstly proposed for adapting the unpredictable variation of the grounding impedance, when the relative motion occurs between the train and the rail. Ultimately, the validity of the novel grounding system applying the adjustable grounding impedance technology is verified under different operational conditions, with the consideration of both TB current and voltage.