Gregorio Godoy

Gregorio Godoy

Auto-generated profile, based on publicly available information

Gregorio Godoy

Departamento de Ingeniería Electrónica de Telecomunicación y Automática, Universidad de Jaén, Linares, Jaén, Spain

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2010 in Ultrasonics
Verified
Journal Article
Closed access
ÓMÓscar Martinez-Graullera
Óscar Martinez-Graullera
CMCarlos J. Martín
Carlos J. Martín
GGGregorio Godoy
Gregorio Godoy
LULuis G. Ullate
Luis G. Ullate

1 November 2008
Verified
Conference Paper
Closed access
CMC. J. Martin
C. J. Martin
ÓMÓscar Martinez-Graullera
Óscar Martinez-Graullera
LUL. G. Ullate
L. G. Ullate
AOA. Octavio
A. Octavio
GGG. Godoy
G. Godoy
In this work we present a new synthetic aperture technique, derived from the conventional SAFT, where only one element in emission and two in reception are used (2R-SAFT). This new technique suppresses the grating lobes of the conventional SAFT and allows obtaining images with a better contrast and signal-noise ratio, at the same time that minimizes the hardware requirements of the imaging systems and maintains a high frame rate.

1 January 2010 in Physics Procedia
Verified
Journal Article
Open access
ÓMÓscar Martinez-Graullera
Óscar Martinez-Graullera
CMC.J. Martín
C.J. Martín
GGG. Godoy
G. Godoy
LUL.G. Ullate
L.G. Ullate
The main challenge faced by 3D ultrasonic imaging with 2D array transducer is the large number of elements required to achieve an acceptable level of quality in the images. Therefore, the optimization of the array layout to reduce the number of active elements in the aperture has been a research topic in the last years. Nowadays, CMUT array technology has made viable the production of 2D arrays with larger flexibility on elements size, shape and position. This is opening new options in 2D array design, allowing to revise as viable alternatives others layouts that had been studied in the past, like circular and Archimedes spiral layout. In this work the problem of designing an imaging system array with a diameter of 60 and a limited number of elements using the Fermat spiral layout has been studied. This study has been done for two different numbers of electronic channels (N =128 and N= 256). As summary, a general discussion of the results and the most interesting cases are presented.Peer Reviewe

1 April 2004 in Ultrasonics
Verified
Journal Article
Closed access
OMO Martı́nez
O Martı́nez
GGG Godoy
G Godoy
MIM.A.G Izquierdo
M.A.G Izquierdo
LUL.G Ullate
L.G Ullate

1 January 2006
Verified
Conference Paper
Closed access
ÓMÓscar Martinez-Graullera
Óscar Martinez-Graullera
MPMontserrat Parrilla
Montserrat Parrilla
LUL. G. Ullate
L. G. Ullate
GGG. Godoy
G. Godoy
CMC. J. Martin
C. J. Martin
Two-dimensional (2D) array designs based on a squared matrix (S-M) distribution of elements require half wavelength (lambda/2) pitch for reducing grating lobes. From this condition, a 2D array for ultrasonic imaging will typically contain several thousand of elements, which are much higher than the number of channels of present image systems. In contrast, segmented-annular (S-A) arrays have lower periodicity than squared patterns and allow increasing the inter-element distance surpassing one wavelength. Thus, the number of elements of the S-A array can be reduced by a factor of six with respect to the S-M array of equal size. However, for large apertures, this number is still a challenge for the existent technology, and thinning techniques are required. In this work, the results of applying the random thinning method to S-A arrays are analysed based on two different approaches: the array factor on the one hand, which considers omni-directional elements vibrating in continuous wave, and the real aperture in wide band on the other hand. Moreover, a comparison with the conventional S-M array of equivalent characteristics is also included. It is shown that the S-A array with pitch d = 1.2lambda, overcomes the equivalent S-M array, producing beams which can be acceptable for ultrasonic image