Óscar Martinez-Graullera

Dr. Óscar Martinez-Graullera

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2010 in Ultrasonics
Verified
Journal Article
Closed access
ÓMÓscar Martinez-Graullera
Óscar Martinez-Graullera
CMCarlos J. Martín
Carlos J. Martín
GGGregorio Godoy
Gregorio Godoy
LULuis G. Ullate
Luis G. Ullate

1 October 2013 in NDT & E International
Verified
Journal Article
Closed access
VPVander T. Prado
Vander T. Prado
RHRicardo T. Higuti
Ricardo T. Higuti
CKClaudio Kitano
Claudio Kitano
ÓMÓscar Martinez-Graullera
Óscar Martinez-Graullera
JAJulio C. Adamowski
Julio C. Adamowski

7 August 2012 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
CMCarlos J. Martin-Arguedas
Carlos J. Martin-Arguedas
DRDavid Romero-Laorden
David Romero-Laorden
ÓMÓscar Martinez-Graullera
Óscar Martinez-Graullera
MPManuel Perez-Lopez
Manuel Perez-Lopez
LGLuis Gomez-Ullate
Luis Gomez-Ullate
The design of newer ultrasonic imaging systems attempts to obtain low-cost, small-sized devices with reduced power consumption that are capable of reaching high frame rates with high image quality. In this regard, synthetic aperture techniques have been very useful. They reduce hardware requirements and accelerate information capture. However, the beamforming process is still very slow, limiting the overall speed of the system. Recently, general-purpose computing on graphics processing unit techniques have been proposed as a way to accelerate image composition. They provide excellent computing power with which a very large volume of data can easily and quickly be processed. This paper describes a new system architecture that merges both principles. Thus, using a minimum-redundancy synthetic aperture technique to acquire the signals (2R-SAFT), and a graphics processing unit as a beamformer, we have developed a new scanner with full dynamic focusing, both on emission and reception, that attains real-time imaging with very few resources.

1 May 2002 in Ultrasonics
Verified
Journal Article
Closed access
MAM. Akhnak
M. Akhnak
ÓMÓscar Martinez-Graullera
Óscar Martinez-Graullera
LUL.G. Ullate
L.G. Ullate
FEF. Montero de Espinosa
F. Montero de Espinosa

27 September 2010 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
RHRicardo Tokio Higuti
Ricardo Tokio Higuti
ÓMÓscar Martinez-Graullera
Óscar Martinez-Graullera
CMCarlos J. Martin
Carlos J. Martin
AOAlberto Octavio
Alberto Octavio
LELuis Elvira
Luis Elvira
FEFrancisco Montero De Espinosa
Francisco Montero De Espinosa
In this work, a high-resolution imaging method for the inspection of isotropic plate-like structures using linear arrays and Lamb waves is proposed. The evaluation of these components is limited by the low dynamic range resulting from main lobe and side lobe field patterns, and from the narrowband nature of the Lamb waves. Based on a full matrix array, synthetic aperture technique using all emitter-receiver combinations, different images from the same object are obtained by using different apodization coefficients, which are related to a trade-off between main lobe width and relative side lobe level. Several image compounding strategies have been tested and a new algorithm, based on apodization and polarity diversities between signals, is proposed. However, some effects, such as the dead zone close to the array and reverberations caused by interactions of the wavefront and defects, still limit the quality of the images. The use of spatial diversity, obtained by an additional array, introduces complementary information about the defects and improves the results of the proposed algorithm, producing high-resolution, high-contrast images. Experimental results are shown for a 1-mm-thick isotropic aluminum plate with artificial defects using linear arrays formed by 30 piezoelectric elements, with the low dispersion symmetric mode S0 at the frequency of 330 kHz.

1 November 2017 in Mechanical Systems and Signal Processing
Verified
Journal Article
Closed access
ATAline E. Takiy
Aline E. Takiy
CKCláudio Kitano
Cláudio Kitano
RHRicardo T. Higuti
Ricardo T. Higuti
SGSilvio C.G. Granja
Silvio C.G. Granja
VPVander T. Prado
Vander T. Prado
ÓMÓscar Martinez-Graullera
Óscar Martinez-Graullera