Yanxiang Yin

Yanxiang Yin

Auto-generated profile, based on publicly available information

Yanxiang Yin

School of Control Science and Engineering, Shandong University, Jinan, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2024 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
Nan WangNan Wang
Nan Wang
WWWei Wang
Wei Wang
CLChanglong Li
Changlong Li
YYYanxiang Yin
Yanxiang Yin
ACAlian Chen
Alian Chen
CZChenghui Zhang
Chenghui Zhang
The charging capability of lithium-ion batteries (LiBs) is inherently limited at low temperatures, resulting in less charging current rates. In this regard, preheating LiBs before charging has been suggested as a solution, however, this requires separate control and additional switching mechanisms. Moreover, this approach cannot simultaneously produce alternating current (AC) and direct current (DC), resulting in reduced charging efficiencies. To overcome these challenges, this research proposes a self-heating and charging coordinated strategy. Furthermore, we propose a dual-active-bridge LC (DAB-LC) converter designed to facilitate simultaneous AC and DC output. A dual-closed-loop controller ensures that the converter can output the maximum acceptable DC of LiBs at the current temperature and state of charge (SOC) and superimposes adaptive AC within the battery safety threshold, thereby substantially enhancing the charging speed. Experimental results demonstrate that the proposed strategy can charge LiBs to 80% SOC in 1.55 h at -10°C, which is 6.65-times faster than the conventional little-current charging method.

15 January 2024 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
WWWei Wang
Wei Wang
YYYanxiang Yin
Yanxiang Yin
Tong LiuTong Liu
Tong Liu
Nan WangNan Wang
Nan Wang
QRQicai Ren
Qicai Ren
ACAlian Chen
Alian Chen
The ${{LLC}}$ converter-based dc transformer is popular for its stiff voltage gain, very high efficiency, and simple control. To avoid excessive start-up inrush current and hardware overdesign, the fixed-frequency variable duty-cycle soft start-up strategy is often adopted. However, in this conventional strategy, the optimal current-limiting curve (OCC) is derived by the challenging numerical model iterative algorithm, which is difficult to model, calculate online, and adapt to different operating conditions. To solve this problem, a closed-form OCC (COCC)-based soft start-up strategy is proposed. The COCC is derived by state-trajectory analysis and can be quickly calculated through the simple closed-form equation, providing greater practicality and flexibility while accurately maximizing the utilization of the allowable peak current. Furthermore, the closed-form equation makes it possible to estimate the start-up capability under the variable duty-cycle strategy. The calculation method of the maximum allowable start-up load is proposed, offering an important basis for the design of distribution system restoration schemes. Finally, a 50-kW dc transformer is built to verify the effectiveness of the proposed strategy under various conditions.

12 September 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YYYanxiang Yin
Yanxiang Yin
Jingyang FangJingyang Fang
Jingyang Fang
Hongchang LiHongchang Li
Hongchang Li
SLSteven Liu
Steven Liu
CZChenghui Zhang
Chenghui Zhang
Due to their merits of high efficiency and power density, resonant dual-active-bridge (DAB) inverters are receiving heightened attention in microinverters. However, the existing models of resonant DAB inverters, such as the first harmonic approximation (FHA) model, are nonlinear without any steady-state operating point and suffer from low accuracy. This article first proposes the dynamic phasor model of resonant DAB inverters that allows the analysis of the resonant inductor current even without any relevant current sensor. Then, by linearizing the proposed large-signal model around the steady-state operating point, this article proposes the high-precision linear small-signal dynamic phasor model of resonant DAB inverters. Moreover, this article derives the analytical expression for the Fourier coefficients of switch functions using the double Fourier series. Simulation and experiments validate the accuracy of the proposed model. The voltage error of the proposed large-signal model under a 50% load change is less than 3%, leading to an accuracy improvement of over 20% compared with the conventional FHA model. Notably, the voltage error of the proposed small-signal model is less than 2%.

23 March 2026 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YYYanxiang Yin
Yanxiang Yin
Jingyang FangJingyang Fang
Jingyang Fang
Hongchang LiHongchang Li
Hongchang Li
CZChenghui Zhang
Chenghui Zhang
Due to its wide voltage gain range and excellent soft-switching performance, the resonant dual-active-bridge (DAB) topology has drawn heightened attention in microinverters. Most existing models of resonant DAB inverters, such as the first harmonic approximation (FHA) model, consider only switching-frequency components, which mainly focus on efficiency optimization. However, these modeling methods fail to handle multi-frequency couplings and consequently lack a linear model of resonant DAB inverters during the entire line-frequency cycle. This article proposes the multiple Fourier series-based 1-D dynamic phasor modeling method that can capture the dynamics of multiple distinct excitation frequencies, including the switching frequency, line frequency, and harmonic frequencies. Subsequently, we propose the multi-frequency coupled model for resonant DAB inverters with the extended-phase-shift modulation. On this basis, the proposed model is linearized for stability analysis. The analysis results verify that the proposed model can accurately predict unstable phenomena. Finally, simulation and experimental results validate the accuracy of the proposed model. The voltage error of the proposed model under a 50% load change is less than 2%, thereby achieving an accuracy improvement of over 20% compared with the FHA model.