Santiago Fabian Cobos

Santiago Fabian Cobos

Auto-generated profile, based on publicly available information

Santiago Fabian Cobos

Oral Radiology Division, Department of Dentistry, Schulich School of Medicine and Dentistry, Western University , London, ON N6A 3K7

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SCSantiago Fabian Cobos
Santiago Fabian Cobos
CNChristopher James Norley
Christopher James Norley
SPSteven Ingo Pollmann
Steven Ingo Pollmann
DHDavid Holdsworth
David Holdsworth
Micro-CT imaging can be used as an effective method for non-destructive testing (NDT) of metal 3D printed parts–including titanium biomedical components fabricated using laser powder-bed-fusion (LPBF). Unfortunately, the cost of commercially available micro-CT scanners renders routine NDT for biomedical applications prohibitively expensive. This study describes the design, manufacturing, and implementation of a cost-effective scanner tailored for NDT of medium-size titanium 3D printed biomedical components. The main elements of the scanner; which include a low-energy (80 kVp) portable x-ray unit, and a low-cost lens-coupled detector; can be acquired with a budget less than $ 11000 USD. The low-cost detector system uses a rare-earth phosphor screen, lens-coupled to a dSLR camera (Nikon D800) in a front-lit tilted configuration. This strategy takes advantage of the improved light-sensitivity of modern full-frame CMOS camera sensors and minimizes source-to-detector distance to maximize x-ray flux. The imaging performance of the system is characterized using a comprehensive CT quality-assurance phantom, and two titanium 3D-printed test specimens. Results show that the cost-effective scanner can survey the porosity and cracks in titanium parts with thicknesses of up to 13 mm of solid metal. Quantitatively, the scanner produced geometrically stable reconstructions, with a voxel size of 118 μm, and noise levels under 55 HU. The cost-effective scanner was able to estimate the porosity of a 17 mm diameter titanium 3D-printed cylindrical lattice structure, with a 0.3% relative error. The proposed scanner will facilitate the implementation of titanium LPBF-printed components for biomedical applications by incorporating routine cost-effective NDT as part of the process control and validation steps of medical-device quality-management systems. By reducing the cost of the x-ray detector and shielding, the scan cost will be commensurate with the overall cost of the validated component.

25 January 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
GHGreg Hong
Greg Hong
JLJunmin Liu
Junmin Liu
SCSantiago F. Cobos
Santiago F. Cobos
TKTina Khazaee
Tina Khazaee
MDMaria Drangova
Maria Drangova
DHDavid Holdsworth
David Holdsworth

26 October 2022 in Medical Physics
Verified
Journal Article
Closed access
SCSantiago Fabian Cobos
Santiago Fabian Cobos
CNChristopher James Norley
Christopher James Norley
HNHristo Nikolaev Nikolov
Hristo Nikolaev Nikolov
DHDavid Holdsworth
David Holdsworth

1 July 2022 in Journal of Medical Imaging
Verified
Journal Article
Open access
PDF file
SCSantiago Fabian Cobos
Santiago Fabian Cobos
CNChristopher James Norley
Christopher James Norley
SPSteven Ingo Pollmann
Steven Ingo Pollmann
DHDavid Holdsworth
David Holdsworth
Purpose: Industrial microcomputed tomography (micro-CT) scanners are suitable for nondestructive testing (NDT) of metal, 3D-printed medical components. Typically, these scanners are equipped with high-energy sources that require heavy shielding and costly infrastructure to operate safely, making routine NDT of medical components prohibitively expensive. Alternatively, fixed-current, low-cost x-ray units could be implemented to perform CT-based NDT of 3D-printed medical parts in a subset of cases, if there is sufficient x-ray transmission for the CT reconstruction. A lack of signal—caused by areas of high attenuation in two-dimensional-projection images of metal objects—leads to artifacts that can make an image-based NDT unreliable. We present the implementation of a dual-exposure technique devised to extend the dynamic range (DR) of a commercially available CT scanner equipped with a low-cost low-energy (80 kV) x-ray unit, increasing the signal-to-noise ratio of highly attenuated areas for NDT of 3D-printed medical components.Approach: Our high-dynamic-range CT (HDR-CT) technique adequately combines projection images acquired at two exposure levels by modifying the integration times of each protocol. We evaluate the performance and limitations of this HDR-CT technique by imaging a series of titanium-alloy test-samples. One of the test-samples was a resolution and conspicuity phantom designed to assess the improvements in void visualization of the proposed methodology. The other test-samples were four porous cylinders, 17 × 40 mm, with 60%, 70%, 80%, and 90% nominal internal porosities.Results: Our HDR-CT technique adequately combines projection images acquired at two exposure levels by modifying the integration times of each protocol. Our results demonstrate that the 12-bit native DR of the CT scanner was increased to effective values of between 14 and 16 bits.Conclusions: The HDR-CT reconstructions showed improved contrast-to-noise and void conspicuity, when compared with conventional CT scans. This extension of DR has the potential to improve defect visualization during NDT of medium-size, titanium-alloy, 3D-printed medical components.

5 June 2026 in Dentomaxillofacial Radiology
Verified
Journal Article
Open access
MBMaryam Buholayka
Maryam Buholayka
RZRama Zouabi
Rama Zouabi
SCSantiago F Cobos
Santiago F Cobos
ATAditya Tadinada
Aditya Tadinada
Objectives: Accurate image registration is essential for successful digital dental implant planning. Surface-based registration, commonly used in clinical software, is sensitive to cone-beam CT (CBCT) artifacts and relies on manual landmark selection, potentially reducing accuracy. Marker-based registration offers improved precision but is underused due to its technical complexity and time demands. The purpose of this ex-vivo study was to evaluate the accuracy of a novel marker-based registration method using limited-view CBCT reconstructions derived from 2 orthogonal projection images and to compare it with a conventional surface-based registration method. Methods: An ex-vivo model consisting of a maxillary arch with removable 3D-printed teeth and a radiographic guide containing radiographic markers was used to simulate 5 metal artifact conditions. Full-view CBCT scans were acquired for each condition. For the conventional method, 3 examiners independently performed dual-scan registrations using user-defined surface landmarks on full CBCT reconstructions. For the proposed method, examiners selected orthogonal projection images where markers were clearly visible and limited-view reconstructions were generated to identify marker centroids. Registration error was measured as the point-to-point distance between corresponding surface reference points, standardized to a common frame of reference. Inter-rater reliability was also assessed. Results: Both methods maintained consistent performance across all artifact conditions. The proposed method demonstrated greater accuracy, with lower point-to-point registration errors and less spatial variation. Inter-rater reliability was excellent for the proposed method and good for the conventional approach. Conclusion: The proposed marker-based registration method using orthogonal projection images and limited-view CBCT reconstructions showed higher accuracy than conventional surface-based registration under controlled ex-vivo conditions. Although the workflow currently requires additional examiner input, it may improve precision in dual-scan protocols for implant planning. Future clinical studies and software developments are required to support clinical implementation.

16 September 2025 in American Journal of Orthodontics and Dentofacial Orthopedics
Verified
Journal Article
Open access
MMMaria Luna Montes
Maria Luna Montes
MZMina Atef Zakhary
Mina Atef Zakhary
SCSantiago F. Cobos
Santiago F. Cobos
CKChia-Ling Kuo
Chia-Ling Kuo
KZKelin Zhong
Kelin Zhong
FUFlavio Uribe
Flavio Uribe
This retrospective in vitro study aimed to assess the accuracy of retainers fabricated using Essix (Dentsply Sirona, Charlotte, NC) and Zendura (Zendura Dental, Fremont, Calif), and to compare the accuracy of intraoral scanners iTero (Align Technology, San Jose, Calif) and TRIOS (3Shape, Copenhagen, Denmark). In addition, regional accuracy across different areas of the mandibular arch was analyzed. A total of 20 standard tessellation language files from postorthodontic treatment mandibular arches (from January 2019 to August 2024) were selected based on specific inclusion criteria. The standard tessellation language files were 3-dimensional printed and scanned using iTero Element 2 and TRIOS 4, then used to fabricate 20 sets of each thermoformed retainer (Zendura and Essix). All models were scanned using micro-computed tomography (Scanco Medical AG, Brüttisellen, Switzerland), serving as the gold standard for accuracy comparisons. Root mean square (RMS) error analysis was used to assess overall and regional accuracy. The RMS error between gold standard and retainers differed significantly overall (P = 0.044), particularly in the anterior (P = 0.030) and premolar (P = 0.017) regions, with greater discrepancies in Zendura retainers. RMS error differences were not significant between intraoral scanners across most regions, except for borderline significance in the anterior region (P = 0.058), in which TRIOS showed larger deviations. Both intraoral scanners demonstrated comparable accuracy. However, Zendura retainers exhibited greater inaccuracies than Essix. Regional analysis showed higher deviations in the molar and lingual regions for scanners and the molar regions for retainers. Importantly, these discrepancies were low and clinically insignificant.