9 November 2023 in IEEE Access
The black-box arc model is a tool that facilitates efficient research based on empirical studies in breaker design and analysis. However, its application has primarily focused on the design of ACCBs, with only a few instances of its implementation in the design of low-voltage (LV) DC circuit breakers (DCCBs) using mechanical methods. In DCCBs with non-zero crossing characteristics, several factors need to be considered in the design process. Therefore, it is crucial to have a reliable and accurate DC arc model to effectively apply black-box arc model studies to actual DCCB designs. Especially, DC Current limiting circuit breaker (CLCB), which has fast operation characteristics through its own over current relays (OCR), requires reliable and accurate modeling because minor factors in the topology can contribute significantly to the interrupting performance. This paper presents a study on the characterization and modeling approach for the DC CLCB, which exhibits somewhat different arc voltage characteristics compared to the general Air Circuit Breaker (ACB). The black-box arc model incorporates existing schwarz and kema arc models, and the Levenberg-Marquardt Algorithm (LMA) is employed to optimize the parameters of each model. An efficient parameter optimization method for the CLCB model is proposed, and the characteristics of factors that should be considered in the design are identified. Consequently, the applicability and reliability of the model are verified through a comparative study with the short-circuit test results of the actual DC CLCB.
10 July 2023 in IEEE Access
Medium voltage direct current (MVDC) transmission system are growing due to their assistive quality in conventional grid and compatibility with renewable power network. MVDC distribution links with “Mixed” overhead (OH) & underground (UG) sections could be devised based on urban planning. UG Cables or substations are indirectly exposed to lightning strikes due to adjacent tower sections. In case of MVDC converter or cable, present researchers do not specify lightning voltage impulse level for related system voltage. Therefore, preluding electromagnetic (EM) transient investigation are required to determine the maximum lightning overvoltages for system peripherals i.e. cable & Modular Multilevel Converter (MMC) substation. This research focuses on analyzing lightning performance of OH transmission towers-cable junction & tower-substation link in case of a shielding failure (SF) and back flashover (BF) for a ±35kV short-length mixed MMC-MVDC transmission scheme. This article provides broad-band modeling method for MMC substation for lightning investigation. In addition, based on a detailed time-domain parametric evaluation in PSCAD/EMTDC program, lightning impulse voltage across the transmission line’s pole insulator and embedded cable section are estimated along with numerical validation relying on travelling wave theory. Effect of project parameters such as tower grounding resistance, riser section surge impedance (which connects cable & OH line) and cable length on lightning overvoltage impacting the cable and connected tower section has been demonstrated.
1 April 2025 in IEEE Access
Valve-side single-phase-to-ground (SPG) faults are atypical yet critical for the operation of half-bridge (HB) Modular Multilevel converter (MMC) bipolar or asymmetrical monopolar systems. For the impacted converter station, these faults may result in non-zero crossing currents on the connected AC grid and cause significant overvoltage on upper arm submodule (SM) capacitors. This article presents an SPG valve-side fault mitigation strategy using a power electronic (PE) fault current limiter (FCL) installed at the grounded terminal of the MMC converter, along with a mechanical DC breaker on the DC transmission line. The FCL transfers converter ground current to a resistive branch during the SPG fault, resulting in zero crossing currents on the AC side of the grid, thus ensuring fault current clearance by grid-side AC circuit breakers. Moreover, the proposed topology limits the fault current magnitude, reducing the impact of SPG valve-side faults on the AC grid. The discontinuous DC line current is cleared by a fast mechanical DC circuit breaker, halting the charging of the upper arm SM capacitor and limiting the overvoltage stress on converter insulation. In addition, the severity of upper arm SM overvoltage in case of SPG fault in long distance HB-MMC bipolar links has been assessed, and the prospect of a passive oscillation DC circuit breaker to curb such overvoltage has been demonstrated. The effectiveness of the protection topology has been verified through PSCAD/EMTDC software and compared with previously proposed SPG fault clearance methods.
19 September 2025 in IEEE Access
The Hybrid Modular Multilevel Converter (HMMC) topology—comprising full-bridge (FB) and half-bridge (HB) submodules—is effective for DC fault clearance in HVDC systems. However, to prevent overvoltage in lower-arm full-bridge submodules (FBSMs) during valve-side single-phase-to-ground (SPG) fault mitigation—an uncommon yet critical internal fault in bipolar HVDC systems—the proportion of FBSMs used must account for approximately 86.6% of the arm voltage, compared to 43.3% for DC-side fault blocking. This diminishes the economic advantage of HMMC over fully full-bridge MMC topology. This paper proposes an HMMC SPG fault mitigation method using thyristor-based current commutation branches on the lower arms and a ground-side mechanical interrupter, while maintaining the minimum number of FBSMs required for conventional DC fault clearance. The method mitigates SPG-resultant lower-arm overvoltage by commutating current into the thyristor branches, after which the mechanical interrupter clear lower arms current, and subsequently thyristor branches are turned-off to clear the SPG-valve side fault. Additionally, the pole current is cleared using a mechanical breaker or passive oscillation DC circuit breaker (CB), effectively suppressing upper-arm submodule (SM) overvoltage under SPG valve-side fault in both short- and long-distance HMMC bipolar links. Although additional equipment is required, it incurs no on-state losses during steady-state operation. The proposed method is compared with existing SPG fault clearance approaches for HMMC bipolar systems. Its effectiveness is validated through PSCAD/EMTDC simulations and benchmarked against prior SPG fault clearance methods for HMMC systems.