Sunidhi Saxena

Sunidhi Saxena

Auto-generated profile, based on publicly available information

Sunidhi Saxena

Banaras Hindu University

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2025 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
RGRajiv Gupta
Rajiv Gupta
GDGauri Devi
Gauri Devi
SSSunidhi Saxena
Sunidhi Saxena
ASArpit Singh
Arpit Singh
AKAjay Kumar
Ajay Kumar

12 January 2026 in Physical Review C
Verified
Journal Article
Open access
SSSunidhi Saxena
Sunidhi Saxena
RGRajiv Gupta
Rajiv Gupta
GDGauri Devi
Gauri Devi
AKAjay Kumar
Ajay Kumar
Using the Monte Carlo HYDJET + + model, we investigate the transverse momentum ( p T ) spectra of heavy-flavor hadrons, namely D 0 , D ¯ 0 , D + , D − , and Λ c , along with the nuclear modification factors of D 0 and D ± in Au + Au collisions at s N N = 200 GeV RHIC energy across various centrality bins. This work extends the earlier study by relaxing the assumption of identical chemical and thermal freezeout and by exploring the effect of a higher chemical freezeout temperature relative to thermal freezeout. The study also explores the centrality and mass dependence of the charm enhancement factor ( γ c ). Furthermore, we investigate medium-induced energy loss, particle-antiparticle asymmetry, and the role of fragmentation in the hadronization process. The HYDJET + + model, with its default parameters, is unable to reproduce heavy hadron yields due to their early thermal freezeout and initial state production of heavy quarks. Therefore, a systematic tuning of model parameters is performed to improve the overall agreement with experimental data. Additionally, to assess the performance of the HYDJET + + model relative to other theoretical approaches, its results are compared with the TAMU, SUBATECH, Torino, and Duke models, for which corresponding simulation data are available. This study shows a decreasing trend in γ c from central to peripheral collisions. Moreover, γ c increases with increasing charm-hadron mass. The model approximately reproduces the experimental data of p T spectra at low and intermediate p T . However, it overestimates the data at high p T , indicating a need for improvements in modeling the energy loss of heavy quarks. The nuclear modification factors ( R A A and R C P ) for D 0 mesons exhibit significant suppression at high p T . At low p T , R A A results show deviations from the data, reflecting limitations in the model where coalescence becomes important. The antiparticle-to-particle ratios are consistent with experimental data, whereas mixed-particle ratios are underestimated, revealing the model's limitation in estimating the baryon-to-meson enhancement.

7 August 2026 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
RGRajiv Gupta
Rajiv Gupta
SSSunidhi Saxena
Sunidhi Saxena
AKAjay Kumar
Ajay Kumar

1 August 2026 in Semiconductor Science and Technology
Verified
Journal Article
Closed access
RGRajiv Gupta
Rajiv Gupta
SSSunidhi Saxena
Sunidhi Saxena
CJChakresh Jain
Chakresh Jain
KTKalpna Tiwari
Kalpna Tiwari
NANamrata Agrawal
Namrata Agrawal
AKAjay Kumar
Ajay Kumar
We present comprehensive technology computer-aided design modeling results for a proton-irradiated, 300 μ m thick low gain avalanche detector (LGAD) with a boron implant dose of 1.6 × 10 13 cm − 2 . We first assess the geometrical and doping parameters of the simulated LGAD through comparison of the electrical and transient current technique characteristics with experimental measurements. Subsequently, we model the effects of proton irradiation on the simulated device. Unlike traditional detectors (PIN and strip detectors), LGADs contain an additional gain layer that facilitates intrinsic charge multiplication but undergoes acceptor removal under irradiation, necessitating the incorporation of these effects in radiation-damage modeling. We employ the Delhi University’s Proton Damage Model (PDM), originally developed for traditional sensors, as a baseline to incorporate radiation-induced trap defects. We then extend the PDM by implementing the acceptor removal mechanism (ARM) to account for the acceptor removal in the gain layer. The simulation results, incorporating the combined PDM and ARM framework, still underestimate the experimental gain, indicating that the model requires further advancements to capture the real device behavior. To understand this discrepancy, we investigate the role of impact ionization in charge multiplication. While the default Selberherr impact ionization model effectively estimated the gain for a non-irradiated LGAD, reproducing the gain of the irradiated LGAD required a fluence-dependent parameterization. This parameterization led to reasonable agreement between the simulated gain and the corresponding gain measurements under red and IR laser illumination. Further, we examine the electrical characteristics of the irradiated device using both the default and the optimized Selberherr impact ionization models to assess the impact of the parameterization. Overall, this work provides comprehensive insights into proton-induced damage in LGADs and highlights the need for refined modeling approaches.